SCOTT BUILDING, INC | B= | C | 06/19/2013 | All other required Final inspections are complete. (This is a computer generated result) | JOND | JOND | | B= | C | 4545712 |
SCOTT BUILDING, INC | B= | P | 06/14/2013 | Additional Inspections Required: External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977). | JOND | JOND | | B= | P | 4543496 |
SCOTT BUILDING, INC | B= | P | 06/13/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977). handrail at garage to house steps / pipe downspouts away from house -- Schedule a new Building Final when above items are complete. | JOND | JOND | | B= | P | 4542734 |
SCOTT BUILDING, INC | BLA | C | 04/02/2013 | flashing above door installed | DANF | DANF | | BLA | C | 4498517 |
SCOTT BUILDING, INC | BLA | R | 03/28/2013 | no drip metal at back service door / give me a call 327-2973 | JOND | JOND | | BLA | R | 4495752 |
SCOTT BUILDING, INC | BLA | R | 03/18/2013 | need flashing above garage door and garage service door on backside | JOND | JOND | | BLA | R | 4489058 |
SCOTT BUILDING, INC | BSP | P | 03/15/2013 | deck post OK | JIMP | JIMP | | BSP | P | 4487863 |
SCOTT BUILDING, INC | BIN | C | 03/04/2013 | no permit to sign | JIMP | JIMP | | BIN | C | 4481114 |
SCOTT BUILDING, INC | BFR | C | 02/28/2013 | | JIMP | JIMP | | BFR | C | 4479463 |
SCOTT BUILDING, INC | BFR | R | 02/27/2013 | header rear great room straps and kings per plan; front window at stairs kings per plan; tbe's at 'CG; tbe's at AG, re-check your trusses for laterial braxcing (example B4 missing brace and all b racing must be attached to roof or ceiling, glue or grout all shims under steel, missing some firestop | JIMP | JIMP | | BFR | R | 4478236 |
SCOTT BUILDING, INC | BIN | P | 02/27/2013 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | SHARON | SHARON | | BIN | P | 4478066 |
SCOTT BUILDING, INC | BSP | P | 02/26/2013 | rear piers OK | JIMP | JIMP | | BSP | P | 4477670 |
SCOTT BUILDING, INC | BTR | C | 02/15/2013 | | JOND | JOND | | BTR | C | 4472636 |
SCOTT BUILDING, INC | BTR | R | 01/29/2013 | too much snow on roof | JOND | JOND | | BTR | R | 4463203 |
SCOTT BUILDING, INC | BSP | P | 01/03/2013 | lids for porches front and rear OK, no post or connectors installed; will need those inspected | JIMP | JIMP | | BSP | P | 4448237 |
SCOTT BUILDING, INC | BFI | C | 12/03/2012 | | JIMP | JIMP | | BFI | C | 4432838 |
SCOTT BUILDING, INC | BFD | C | 12/03/2012 | | JIMP | JIMP | | BFD | C | 4432836 |
SCOTT BUILDING, INC | BFN | C | 11/28/2012 | drain usable space; isolate pads; float walls; eufer installed; 5% grade at final; need typed open hole at drain | JIMP | JIMP | | BFN | C | 4429655 |
SCOTT BUILDING, INC | BFT | C | 11/26/2012 | | JIMP | JIMP | | BFT | C | 4427571 |
SCOTT BUILDING, INC | BFT | R | 11/21/2012 | not started after 12; OK'd for engineer to do inspection | JIMP | JIMP | | BFT | R | 4426698 |
D & J QUALITY ELECTRIC INC | E= | C | 06/06/2013 | | MIKEC | MIKEC | | E= | C | 4538158 |
D & J QUALITY ELECTRIC INC | E= | R | 06/05/2013 | ARC SHIELD INSTALLED INCORRECTLY LAUNDRY OUTLET 40 AMP A.C | MIKEC | MIKEC | | E= | R | 4536997 |
D & J QUALITY ELECTRIC INC | E= | R | 06/05/2013 | ARC SHIELD NOT INSTALLED CORRECTLY LAUNDRY OUTLET | MIKEC | MIKEC | | E= | R | 4536963 |
D & J QUALITY ELECTRIC INC | ER | C | 02/20/2013 | NO MULTI WIRE #6AL----FINISHED BASEMENT DEAN APPROVED NO OUTLETS AT WINDOWS----- | TIMA | TIMA | | ER | C | 4475066 |
D & J QUALITY ELECTRIC INC | ES | C | 02/19/2013 | Residential Underground: 200 AMP 3/W NEW RES, | TIMA | TIMA | | ES | C | 4474022 |
D & J QUALITY ELECTRIC INC | ER | R | 02/19/2013 | ADD HALL OUTLET TO MASTER BATH,NEED OUTLET THEATER ROOM WALL SCREEN WALL,SEAL AIR RETURN BASEMENT AT BEDROOM HALL,BOX IN AIR RETURN BASEMENT BEDROOM | TIMA | TIMA | | ER | R | 4474021 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | H= | C | 05/31/2013 | Final complete. Note: high/low transfer, full a/c. | MICHAELS | MICHAELS | | H= | C | 4534540 |
L & L GAS SHOP, LLC. | HC | C | 02/26/2013 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4477629 |
L & L GAS SHOP, LLC. | HI | C | 02/26/2013 | 10# test ok. 1 1/4" main to furn, 2-w/h, 3-fp, c-top. | MICHAELS | MICHAELS | | HI | C | 4477627 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | C | 02/20/2013 | Duct design and equipment ok. Note: FB, 6" osa to return, a/c rough(coil and lineset), direct vent furnace. | MICHAELS | MICHAELS | | HRR | C | 4475041 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | R | 02/15/2013 | POST ADDRESS, did not find duct design on site, b-vent is against roof deck, fp vent from basement lacks clearance to framing on main, Re-inspect all. No permit card on site. | MICHAELS | MICHAELS | | HRR | R | 4472961 |
J.J. BROOME PLUMBING AND HEATING LLC | P= | C | 06/03/2013 | HAS R.P. FOR IRRIGATION | LEE | LEE | | P= | C | 4535753 |
J.J. BROOME PLUMBING AND HEATING LLC | PTO | C | 02/19/2013 | | LEE | LEE | | PTO | C | 4474216 |
J.J. BROOME PLUMBING AND HEATING LLC | PTO | P | 02/13/2013 | NO CARD -- LACKS FREEZE PROTECTION AT W-BOX P-TRAP -- LOW TEST ON H20 -- NAIL PROTECTION MISSING ON GARAGE WALL X-6 AND MASTER LAV | LEE | LEE | | PTO | P | 4471668 |
J.J. BROOME PLUMBING AND HEATING LLC | PB | C | 12/10/2012 | | LEE | LEE | | PB | C | 4437538 |