PEAK SIDE PROPERTIES, LLC | B= | C | 07/31/2013 | All other required Final inspections are complete. (This is a computer generated result) | JOND | JOND | | B= | C | 4575199 |
PEAK SIDE PROPERTIES, LLC | B= | P | 07/30/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). | JOND | JOND | | B= | P | 4574277 |
PEAK SIDE PROPERTIES, LLC | BFR | C | 07/30/2013 | | JOND | JOND | | BFR | C | 4574272 |
PEAK SIDE PROPERTIES, LLC | B= | R | 07/29/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977). house numbers need to have a 1/2" stroke / need frame signed off / seal all exterior penetrations / finished basement | JOND | JOND | | B= | R | 4573854 |
PEAK SIDE PROPERTIES, LLC | BFR | R | 07/29/2013 | front porch has never been inspected, need to take off one of the soffit panels | JOND | JOND | | BFR | R | 4573853 |
PEAK SIDE PROPERTIES, LLC | BSP | P | 07/02/2013 | deck piers ok | JOND | JOND | | BSP | P | 4555874 |
PEAK SIDE PROPERTIES, LLC | BM | R | 06/18/2013 | don't need a masonry inspection | JOND | JOND | | BM | R | 4545237 |
PEAK SIDE PROPERTIES, LLC | BSP | P | 06/17/2013 | steel angle over garage header ok | JOND | JOND | | BSP | P | 4544388 |
PEAK SIDE PROPERTIES, LLC | BFR | R | 05/07/2013 | front porch and deck frame still not done / brace off end of lateral / steel angle at garage still not done / engineer letters on file for fixes and for cmu on top of foundation | JOND | JOND | | BFR | R | 4519147 |
PEAK SIDE PROPERTIES, LLC | BIN | P | 05/07/2013 | insulation ok / need frame signed off | JOND | JOND | | BIN | P | 4519089 |
PEAK SIDE PROPERTIES, LLC | BFR | R | 04/30/2013 | need HI and Hrr signed off / front porch and deck frame not ready / brace off ends of laterals / XX02 not bearing per design / 2 kings at header in master bedroom / layout not matching plans at upper floor framing / plans show steel angle above garage headers / need plans showing how tji's are connecting into ledger at front roof in front of garage / need letter on cutting bottom cord out of If12 trusses in basement / need to isolate bearing wall footer in basement / ok to insulate | JOND | JOND | | BFR | R | 4514743 |
PEAK SIDE PROPERTIES, LLC | BFD | C | 02/20/2013 | | JIMP | JIMP | | BFD | C | 4474697 |
PEAK SIDE PROPERTIES, LLC | BFN | C | 02/20/2013 | see engineers observation scanned in | JIMP | JIMP | | BFN | C | 4474696 |
PEAK SIDE PROPERTIES, LLC | BFT | C | 02/20/2013 | see engineers observation scanned in | JIMP | JIMP | | BFT | C | 4474695 |
PEAK SIDE PROPERTIES, LLC | BSP | T | 02/20/2013 | PAID (REC#1112413) ADDITIONAL PLAN REVIEW TIME: $500 From: JAY Work without permit per RBD103.12 - Jim Pepper will provide report to Board of Review. | JAY | JAY | | BSP | T | 4474568 |
PEAK SIDE PROPERTIES, LLC | BFT | R | 02/19/2013 | issued stop work order | JIMP | JIMP | | BFT | R | 4474363 |
PEAK SIDE PROPERTIES, LLC | BFN | R | 02/19/2013 | issued stop work order | JIMP | JIMP | | BFN | R | 4474362 |
PEAK SIDE PROPERTIES, LLC | BFD | R | 02/19/2013 | issued stop work order | JIMP | JIMP | | BFD | R | 4474360 |
PEAK SIDE PROPERTIES, LLC | BFN | P | 02/08/2013 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 4469062 |
PEAK SIDE PROPERTIES, LLC | BFT | P | 02/08/2013 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 4469061 |
TRUSTED ELECTRIC | E= | C | 07/23/2013 | correction made | CRAIGS | CRAIGS | | E= | C | 4569719 |
TRUSTED ELECTRIC | E= | R | 07/22/2013 | label all breakers including spares,gfci to high in mech room (3), no power washer circuit. | BRET | BRET | | E= | R | 4568920 |
TRUSTED ELECTRIC | ES | C | 04/25/2013 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4512178 |
TRUSTED ELECTRIC | ER | C | 04/25/2013 | | MIKEC | MIKEC | | ER | C | 4512166 |
TRUSTED ELECTRIC | ES | R | 04/24/2013 | NOT READY | MIKEC | MIKEC | | ES | R | 4511496 |
TRUSTED ELECTRIC | ER | R | 04/24/2013 | NOT READY | MIKEC | MIKEC | | ER | R | 4511492 |
ADVANTAGE HEATING AND COOLING | H= | C | 07/23/2013 | All OK. Notes: louvered door to mech with open stairwell - full AC - No FP mantel at this time | JERRYF | JERRYF | | H= | C | 4569681 |
ADVANTAGE HEATING AND COOLING | HC | C | 04/30/2013 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4514607 |
ADVANTAGE HEATING AND COOLING | HRR | C | 04/30/2013 | Corrections made. | MICHAELS | MICHAELS | | HRR | C | 4514605 |
BEST YET PLUMBING | HI | C | 04/29/2013 | 10# test ok. | MICHAELS | MICHAELS | | HI | C | 4513710 |
BEST YET PLUMBING | HI | P | 04/26/2013 | PIPING INCOMPLETE TO FIREPLACE -- FURNACE, W/H, F/P, RNG, BBQ | LEE | LEE | | HI | P | 4513132 |
ADVANTAGE HEATING AND COOLING | HRR | P | 04/23/2013 | Need fp installed and framed, dryer vent lacks nail protection, Rest ok. Note: duct design, FB, a/c rough(coil and lineset), direct vent furnace and w/h, 6" osa. | MICHAELS | MICHAELS | | HRR | P | 4510813 |
BEST YET PLUMBING | P= | C | 07/24/2013 | | LEE | LEE | | P= | C | 4571034 |
BEST YET PLUMBING | P= | P | 07/22/2013 | STEAM UNIT REQUIRES MIN. 6" CLEARANCE ON ALL SIDES AND PLACED IN A WELL VENTILATED AREA -- 3" REQUIRED C/O IS BEHIND THE W/H (NO ACCESS) -- LACKS IRRIGATION DRAIN DOWN VALVE IN MECH. ROOM AND PLEASE EXPLAIN 2ND STUB ON IRRIGATION (FOUND ONLY ONE SPOT FOR A BACKFLOW ?) | LEE | LEE | | P= | P | 4568696 |
BEST YET PLUMBING | PTO | C | 04/24/2013 | | LEE | LEE | | PTO | C | 4511674 |
BEST YET PLUMBING | PB | C | 02/26/2013 | | LEE | LEE | | PB | C | 4477977 |