BUILTRITE BUILDERS | B= | C | 11/13/2013 | All other required Final inspections are complete. (This is a computer generated result) | JOND | JOND | | B= | C | 4640287 |
BUILTRITE BUILDERS | B= | P | 11/12/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). | JOND | JOND | | B= | P | 4639757 |
BUILTRITE BUILDERS | B= | P | 11/08/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), Plumbing Final Inspection is not Completed yet. need plumbing final signed off / need to pipe sump pit out / unfinished basement -- Schedule a new Building Final when above items are complete. | JOND | JOND | | B= | P | 4638626 |
BUILTRITE BUILDERS | BLA | C | 09/13/2013 | | JOND | JOND | | BLA | C | 4604174 |
BUILTRITE BUILDERS | BIN | C | 08/26/2013 | | DANF | DANF | | BIN | C | 4592798 |
BUILTRITE BUILDERS | BFR | C | 08/26/2013 | | DANF | DANF | | BFR | C | 4592797 |
BUILTRITE BUILDERS | BFR | R | 08/20/2013 | 2 laterals at E07 and E06 / 2 st22 straps at 3 ml beam by kitchen / strap at steel beam to post by kitchen / laterals missing at C01 and E02 / 2 st22 straps at girder in garage / anchor bolts in garage at breaks / plans show 3 lvl at front in basement / wood in beam pockets / check anchor bolts in plates in basement / ok to insulate | JOND | JOND | | BFR | R | 4588991 |
BUILTRITE BUILDERS | BSP | P | 08/08/2013 | Front and rear porch posts and lids OK | JEREMYA | JEREMYA | | BSP | P | 4581445 |
BUILTRITE BUILDERS | BFD | C | 04/08/2013 | | JOND | JOND | | BFD | C | 4501879 |
BUILTRITE BUILDERS | BFN | C | 04/08/2013 | concrete is 12" or more above window bucks | JOND | JOND | | BFN | C | 4501857 |
BUILTRITE BUILDERS | BFN | P | 04/02/2013 | concrete over window bucks show 12" contractor has only 9 1/2" need letter to OK or correct as per plans; Entech foundation design and open hole observation on file; drain, usable, ISO, flaot, 5% slope from foudnation; Ufer OK | DANF | DANF | | BFN | P | 4498483 |
BUILTRITE BUILDERS | BFT | C | 03/28/2013 | | JOND | JOND | | BFT | C | 4495782 |
BUILTRITE BUILDERS | BFN | P | 03/14/2013 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFN | P | 4487705 |
BUILTRITE BUILDERS | BFT | P | 03/14/2013 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFT | P | 4487704 |
POSITIVE ELECTRIC, LLC | E= | C | 10/31/2013 | | MIKEC | MIKEC | | E= | C | 4633659 |
POSITIVE ELECTRIC, LLC | E= | R | 10/30/2013 | FRONT WP COVER BROKEN 40 AMP A.C | MIKEC | MIKEC | | E= | R | 4632571 |
POSITIVE ELECTRIC, LLC | ES | C | 09/17/2013 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4605742 |
POSITIVE ELECTRIC, LLC | ES | R | 08/16/2013 | NEED TO CHANGE FAULT CURRENT RATING | MIKEC | MIKEC | | ES | R | 4586756 |
POSITIVE ELECTRIC, LLC | ER | C | 08/16/2013 | UNFINISHED BASEMENT | MIKEC | MIKEC | | ER | C | 4586748 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 10/30/2013 | OK NOTES: A/C INSTALLED, UNFINISHED BASEMENT | KEITHW | KEITHW | | H= | C | 4632567 |
RIDGEVIEW PLUMBING | HI | C | 08/19/2013 | CONFIRM SUPPORT ON 1/2" GAS LINE TO FIREPLACE AT FINAL | JERRYF | JERRYF | | HI | C | 4588080 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 08/02/2013 | RELEASE METER | JERRYF | JERRYF | | HC | C | 4577503 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 08/02/2013 | CORRECTIONS MADE - AT FINAL EXTEND FURNACE FLUE INTO TERMINATION AND COMPLETE WATER HEATER FLUE CONNECTION | JERRYF | JERRYF | | HRR | C | 4577502 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 08/01/2013 | TAR PAPER ON WH FLUE - BY FINAL EXTEND PVC FLUE INTO PROPER LOCATION ON FURNACE TERMINATION AND COMPLETE WATER HEATER FLUE CONNECTION REST OK. NOTES: UNFINISHED BASEMENT - COIL AND LINESET | JERRYF | JERRYF | | HRR | P | 4576546 |
RIDGEVIEW PLUMBING | HI | P | 06/26/2013 | 10# test ok. Add support to 1/2" line and at furnace. 1 1/4" main to furn, w/h, fp. | MICHAELS | MICHAELS | | HI | P | 4551403 |
RIDGEVIEW PLUMBING | P= | C | 11/08/2013 | HAS R.P FOR IRRIGATION | LEE | LEE | | P= | C | 4638803 |
RIDGEVIEW PLUMBING | P= | R | 10/18/2013 | ALL LOCKED UP | LEE | LEE | | P= | R | 4625581 |
RIDGEVIEW PLUMBING | PTO | C | 08/20/2013 | | LEE | LEE | | PTO | C | 4589325 |
RIDGEVIEW PLUMBING | PTO | P | 07/02/2013 | NO CHANGES AT THE UPPER SHOWER VALVE (ONLY 2" BEHIND COPPER / VALVE FOR INSULATION ??) | LEE | LEE | | PTO | P | 4556108 |
RIDGEVIEW PLUMBING | PTO | P | 06/26/2013 | MASTER W/C NOT VENTED TO CODE, IF GOING TO VENT WITH FIXTURES UPSTREAM INCREASE TO 3" TO TUB WITH NO 90S ON OFFSET -- UPPER BATH HAS VENT TIE-IN BELOW FLOOD RIM -- LOW TEST ON H20 (64 PSI ??) -- WATER PIPING IN EXTERIOR WALLS IN GARAGE AND UPPER SHOWER LACK ROOM FOR 3.5" OF INSULLATION BEHIND THEM | LEE | LEE | | PTO | P | 4551896 |
RIDGEVIEW PLUMBING | PB | C | 04/12/2013 | | LEE | LEE | | PB | C | 4505303 |