R & R GENERAL CONTRACTING INC. | B= | C | 04/08/2014 | All other required Final inspections are complete. (This is a computer generated result) | BLAKE | BLAKE | | B= | C | 4716075 |
R & R GENERAL CONTRACTING INC. | B= | P | 04/08/2014 | Additional Inspections Required: External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977). ok pending all other finals | BLAKE | BLAKE | | B= | P | 4715941 |
R & R GENERAL CONTRACTING INC. | B= | P | 03/21/2014 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977), Mechanical Final Inspection is not Completed yet. Mechanical final needs complete / Deck not complete, temporary guard put up in master bedroom in front of slider to deck | NICK | NICK | | B= | P | 4706272 |
R & R GENERAL CONTRACTING INC. | BSP | P | 03/14/2014 | deck piers ok | JOND | JOND | | BSP | P | 4702807 |
R & R GENERAL CONTRACTING INC. | BFR | C | 01/13/2014 | | JOND | JOND | | BFR | C | 4670867 |
R & R GENERAL CONTRACTING INC. | BIN | C | 01/13/2014 | | JOND | JOND | | BIN | C | 4670866 |
R & R GENERAL CONTRACTING INC. | BFR | P | 01/06/2014 | can't use cardboard material for firestop above fireplaces | JOND | JOND | | BFR | P | 4666961 |
R & R GENERAL CONTRACTING INC. | BIN | P | 01/06/2014 | insulation ok, need frame signed off | JOND | JOND | | BIN | P | 4666951 |
R & R GENERAL CONTRACTING INC. | BFD | C | 01/02/2014 | | JOND | JOND | | BFD | C | 4665617 |
R & R GENERAL CONTRACTING INC. | BFR | R | 01/02/2014 | need HI+ signed off / laterals missing at A trusses / tie off ends of laterals / firestop / fireblock garage brackets / strong back gable in garage / need lgt2 on B2 girder and hts20 / roll block trusses at common wall / missing steel mini post at beam pocket in basement / ok to insulate | JOND | JOND | | BFR | R | 4665616 |
R & R GENERAL CONTRACTING INC. | BLA | C | 12/31/2013 | stop insulating a frame has never been done | JOND | JOND | | BLA | C | 4664711 |
R & R GENERAL CONTRACTING INC. | BIN | P | 12/31/2013 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | CHERYL | CHERYL | | BIN | P | 4664551 |
R & R GENERAL CONTRACTING INC. | BLA | R | 12/27/2013 | need flashing at deck ledger done properly | JOND | JOND | | BLA | R | 4663345 |
R & R GENERAL CONTRACTING INC. | BFD | T | 09/17/2013 | PAID (REC#1157017) not ready still installing drain at 10:41 | JOND | JOND | | BFD | T | 4605555 |
R & R GENERAL CONTRACTING INC. | BFN | C | 09/10/2013 | design and soils on file / drain usable area / ufer rod in | JOND | JOND | | BFN | C | 4601527 |
R & R GENERAL CONTRACTING INC. | BFN | R | 09/09/2013 | not ready | JOND | JOND | | BFN | R | 4600655 |
R & R GENERAL CONTRACTING INC. | BFT | C | 09/03/2013 | | JOND | JOND | | BFT | C | 4597169 |
BEAR NECESSITY ELECTRIC INC | E= | C | 03/19/2014 | A.C PREWIRE | MIKEC | MIKEC | | E= | C | 4705018 |
BEAR NECESSITY ELECTRIC INC | ES | C | 12/20/2013 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4660894 |
BEAR NECESSITY ELECTRIC INC | ER | C | 12/20/2013 | UNFINISHED BASEMENT | MIKEC | MIKEC | | ER | C | 4660891 |
M W MECHANICAL INC | H= | C | 03/21/2014 | OK NOTE UNFINISHED BASEMENT NO A/C | DAVIDH | DAVIDH | | H= | C | 4706382 |
M W MECHANICAL INC | HC | C | 01/14/2014 | OK TO SET METER. | NANCY | NANCY | | HC | C | 4671812 |
M W MECHANICAL INC | HC | C | 01/14/2014 | OK for meter | JACK | JACK | | HC | C | 4671567 |
M W MECHANICAL INC | HI+ | C | 01/13/2014 | 10 PSI TEST OK NOTES: SEE HI FOR NOTES | KEITHW | KEITHW | | HI+ | C | 4670535 |
M W MECHANICAL INC | H16 | C | 12/30/2013 | NEED HI+ INSPECTION TO GET METER RELEASE. GAS LINE IN BASEMENT HAS BEEN CUT AND REMOVED DUE TO CONFLICT WITH DUCTS IN MECHANICAL ROOM. BASEMENT IS UNFINISHED, ALL NEW GAS LINE WILL BE IN BASEMENT. CALL FOR HI+ INSPECTION WHEN GAS LINE HAS BEEN INSTALLED. | NANCY | NANCY | | H16 | C | 4664340 |
M W MECHANICAL INC | HRR | C | 12/30/2013 | AT FINAL HAVE KITCHEN DOWN DRAFT INSTALLATION INSTRUCTIONS ON SITE, NEED TO VERIFY TERMINATION CAP. BY FINAL NEED REVISED/APPROVED NEW DUCT DESIGN AND NEW EQUIPMENT CERTIFICATE. | NANCY | NANCY | | HRR | C | 4664333 |
M W MECHANICAL INC | HRR | P | 12/27/2013 | GAS LINE HAS BEEN CUT AND IS BEING REINSTALLED. WILL NEED HI+ INSPECTION FOR NEW GAS LINE. THIS CONTRACTOR WILL NOT BE COMPLETED ON HRR UNTIL HI+ HAS BEEN ADDED TO PERMIT. VERIFY TERMINATION TYPE REQUIRED BY DOWN DRAFT MANUFACTURER, HAVE PAPERWORK FOR DOWN DRAFT ON SITE AT NEXT INSPECTION. NEED 1 INCH CLEARANCE FROM B-VENT TO ROOF DECK. NAIL PROTECT DRYER VENT. NEED 100 SQUARE INCHES OF MAKE-UP AIR FOR LAUNDRY ROOM, CAN BE INSTALLED AT ROUGH OR BY FINAL.. BY FINAL NEED REVISED/APPROVED DUCT DESIGN SHOWING OUTSIDE AIR TO FURNACE RETURN AND FLEX DUCTS INSTALLED AT END OF TRUNK LINE. PROVIDE REVISED/APPROVED EQUIPMENT CERTIFICATE FOR 100,000 95% FURNACE INSTALLED (ORIGINAL DESIGN IS 88,000 83%). NOTE: UNFINISHED BASEMENT. OUTSIDE AIR TO FURNACE RETURN. A/C ROUGH, COIL AND LINESET. DIRECT VENT FURNACE. | NANCY | NANCY | | HRR | P | 4663516 |
M W MECHANICAL INC | HRR | R | 12/23/2013 | WAIVED TRIP FEE, SPENT TIME WITH CONTRACTOR ON SITE TO MAKE SURE INSPECTION PROCESS IS UNDERSTOOD. HOUSE IS TO BE COMPLETELY ROUGHED IN, THIS INCLUDES ALL MECHANICAL WORK, LINE SETS, FIREPLACE, DUCT SEALING ETC. MAY HAVE ISSUES WITH WATER HEATER VENT HAVING TO MANY OFFSETS PER CODE. CONTRACTOR TO MAKE SURE ALL MEETS CODE BEFORE NEXT INSPECTION. MUST MEET DUCT DESIGN AND ENSURE ALL PLANS AND PAPER WORK IN PLACE. MUST USE PROPER DUCT FITTINGS PER SMACNA AND DUCT DESIGN LAYOUT. ALL DUCT MUST BE SEALED PROPERLY. | JON | JON | | HRR | R | 4661857 |
M W MECHANICAL INC | HI | C | 12/20/2013 | 10 PSI TEST OK NOTES: 1 1/4" GAS LINE, FURNACE, WATER HEATER, COOKTOP, 2-FIREPLACE, BBQ | KEITHW | KEITHW | | HI | C | 4660967 |
M W MECHANICAL INC | HRR | P | 12/20/2013 | NOT READY | KEITHW | KEITHW | | HRR | P | 4660965 |
LONGO PLUMBING | P= | C | 03/21/2014 | no irrigation | JOEL | JOEL | | P= | C | 4706271 |
CASCADE PLUMBING & HEATING | PTO | C | 12/31/2013 | No tees installed for future sinks in basement and no water lines for the master bath sinks | JACK | JACK | | PTO | C | 4664890 |
CASCADE PLUMBING & HEATING | PTO | P | 12/19/2013 | INSTALL SAN-TEES ON FUTURE LAV / BAR STACKS AND TEST THRU THEM -- SEVERAL WATER LINES IN EXTERIOR WALLS LACK THE MIN. 3.5" FOR INSULATION BEHIND THEM | LEE | LEE | | PTO | P | 4660694 |
CASCADE PLUMBING & HEATING | PB | C | 10/01/2013 | | LEE | LEE | | PB | C | 4614481 |
CASCADE PLUMBING & HEATING | PB | R | 09/30/2013 | NO TEST -- PIPE ALL COVERED UP | LEE | LEE | | PB | R | 4613550 |