HOMEOWNER | B= | C | 05/25/2016 | All other required Final inspections are complete. (This is a computer generated result) | DAN | DAN | | B= | C | 5207820 |
HOMEOWNER | B= | P | 05/25/2016 | guard installed at entry walk; door removed bottom of basements steps. Building OK. Additional Inspections Required (computer generated): External Agency Inspection N= by WP ENGINEERING is not Completed yet. | DAN | DAN | | B= | P | 5207676 |
HOMEOWNER | B= | R | 05/23/2016 | Basement unfinished; 1) guard rail at entry sidewalk 2) Slope at entry side walk 1 to 1 slope. retaining wall required. 3) basement handrail need 1.5" to wall and to go to bottom of steps. 4) doors swing over step in garage and bottom of steps. Landing on other side of threshold will fix it. 5) need 5% slope from foundation at 10' out need 6" down. 6) need Woodland Park sign off. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet, External Agency Inspection N= by WP ENGINEERING is not Completed yet. | DAN | DAN | | B= | R | 5206268 |
HOMEOWNER | BLA | P | 04/12/2016 | lath for stone does not require an inspection | DAN | DAN | | BLA | P | 5175616 |
HOMEOWNER | BIN | C | 01/27/2016 | | DAN | DAN | | BIN | C | 5124072 |
HOMEOWNER | BFR | C | 01/27/2016 | | DAN | DAN | | BFR | C | 5124067 |
HOMEOWNER | BIN | P | 01/22/2016 | missing insulation in master bedroom coffer ceiling. Recall | DAN | DAN | | BIN | P | 5121135 |
HOMEOWNER | BFR | P | 01/22/2016 | engineering on file on file from Charles Milligan, #34608 for bearing fix and sizing of nook header and Roseburg joists. Still have basement stair rise problem. Per Home owner Scott he will cut in new stairs. and will call frame inspection.
| DAN | DAN | | BFR | P | 5121133 |
HOMEOWNER | BFR | P | 01/13/2016 | OK to insulate; letter on file for 3-11 7/8" lvl to support R02 trusses at kitchen opening to kitchen ; 1) Roll block truss heels greater then 8" in garage, master bedroom etc. 2) firestop fireplace. 3) Missing bearing block on girder truss R117 both ends north east bedroom , 30" block and 2 16d 6" oc 4) need Letter for sizing header at kitchen nook/bay. 5) need letter to substitute Roseburg RFPI 400 joists. 6) basement stairs rise 8" 7) No bearing for south end of 3 11 7/8"lvl that supports R02 trusses at kitchen opening. 8) missing truss lateral bracing on R121 in garage web B-O | DAN | DAN | | BFR | P | 5115361 |
HOMEOWNER | BSP | T | 12/15/2015 | PAID (REC#1304204) PLAN SPLICE FEE: $50 by: JIMA for Construction: splice added trusses over great room - new roof framing plans and added R01 - 02 - 03 TRUSSES | JIMA | JIMA | | BSP | T | 5098829 |
HOMEOWNER | BFI | R | 09/17/2015 | R10 24" down at walkout. | DAN | DAN | | BFI | R | 5038967 |
HOMEOWNER | BFD | C | 09/17/2015 | usable; day light left front corner. | DAN | DAN | | BFD | C | 5038964 |
HOMEOWNER | BFN | C | 09/16/2015 | soils report, open hole excavation on file; ISO, float, 5% slope from foundation; drain usable. Ufer OK; foundation design scanned with approved plans. | DAN | DAN | | BFN | C | 5037255 |
HOMEOWNER | BFT | C | 09/16/2015 | footer observation on file from Charles Milligan, #34608 | DAN | DAN | | BFT | C | 5037243 |
HOMEOWNER | BSP | P | 09/15/2015 | Met with Christine regarding need for footer and foundation steel foundation observation by an engineer. need open hole observation and soils report. Foundation drain requirements will be reviewed with home owner when received. Recall the above inspections. | DAN | DAN | | BSP | P | 5036672 |
HOMEOWNER | E= | C | 05/17/2016 | | MIKEC | MIKEC | | E= | C | 5200893 |
HOMEOWNER | ES | C | 04/12/2016 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 5174772 |
HOMEOWNER | ES | R | 02/09/2016 | SUB PANEL INCORRECT | MIKEC | MIKEC | | ES | R | 5130917 |
HOMEOWNER | ER | C | 01/12/2016 | | MIKEC | MIKEC | | ER | C | 5114134 |
HOMEOWNER | ER | R | 01/04/2016 | 3 gang box in garage fire wall where 2 gang max without separation. (switch box and garage entry to home) install running boards at all attic access (protect cable with in 6' of access) add receptacle within 25 of panel in basement. | BRET | BRET | | ER | R | 5109196 |
HOMEOWNER | EUG | C | 12/21/2015 | | MIKEC | MIKEC | | EUG | C | 5103154 |
COMFORT CONTROL, INC. | H= | C | 05/17/2016 | DIRECT VENT FURNACE, 5 - SUPPLY AIR AND 1 - RETURN IN THE UNFINISHED BASEMENT. | JEFFB | JEFFB | | H= | C | 5200941 |
COMFORT CONTROL, INC. | HC | C | 01/07/2016 | RELEASE METER | LUKE | LUKE | | HC | C | 5112205 |
COMFORT CONTROL, INC. | HRR | C | 01/07/2016 | UNFINISHED BASEMENT, NO OUTSIDE AIR, NO A/C, | LUKE | LUKE | | HRR | C | 5112201 |
MD SERVICE PLUMBING, INC. | HI | C | 01/07/2016 | 10# GAS TEST GOOD. 1'' MAIN FURNACE AND WATER HEATER.. | LUKE | LUKE | | HI | C | 5112196 |
COMFORT CONTROL, INC. | HRR | R | 12/09/2015 | Seal wires main floor RA kitchen island or use blocking, main floor fireplace not set. Leave approved set of plans on site at re-inspect. Re-inspect all. | STEVEC | STEVEC | | HRR | R | 5095084 |
MD SERVICE PLUMBING, INC. | P= | C | 05/13/2016 | THE EXPANSION TANK HAS BEEN INSTALLED AND THE PEX CLEARANCE IS GOOD. | JEFFB | JEFFB | | P= | C | 5199295 |
MD SERVICE PLUMBING, INC. | P= | P | 05/12/2016 | need expansion device ( meter has check valve ), need 6 inches of clearance from single wall vent to pex above water heater, rest ok, unfinished basement, no irrigation. | TAYLOR | TAYLOR | | P= | P | 5197904 |
MD SERVICE PLUMBING, INC. | PTO | C | 12/08/2015 | corrections made, no irrigation. | TAYLOR | TAYLOR | | PTO | C | 5094207 |
MD SERVICE PLUMBING, INC. | PTO | P | 12/02/2015 | install and test sprinkler line/ hose bib, re-grade lav drain at hall bath, vent for washer, master tub drain, rest ok, unfinished basement, aav's at hall bath lav, kitchen, left master lav, basement, need mixing valve for master tub by final. | TAYLOR | TAYLOR | | PTO | P | 5090336 |
MD SERVICE PLUMBING, INC. | PB | C | 11/10/2015 | | TAYLOR | TAYLOR | | PB | C | 5076671 |