GOETZMANN CUSTOM HOMES, INC. | B= | C | 01/03/2017 | | LINDSEY | LINDSEY | | B= | C | 5380952 |
GOETZMANN CUSTOM HOMES, INC. | BIN | C | 10/05/2016 | corrections complete | ERICR | ERICR | | BIN | C | 5310424 |
GOETZMANN CUSTOM HOMES, INC. | BFR | C | 10/04/2016 | corrections completed / received architects stamped changes for framing | ERICR | ERICR | | BFR | C | 5310010 |
GOETZMANN CUSTOM HOMES, INC. | BIN | P | 10/04/2016 | need to insulate around tub and vapor barrier | ERICR | ERICR | | BIN | P | 5310009 |
GOETZMANN CUSTOM HOMES, INC. | BLA | C | 10/04/2016 | | ERICR | ERICR | | BLA | C | 5310007 |
GOETZMANN CUSTOM HOMES, INC. | BFR | P | 09/30/2016 | need 2 HTS 16 on girder on south side of entry / need engineers letter on change from steel column to 4 ply wood column north wall of basement under steel beam / need elevation change fro east wall where windows were added / need A35 on joist for stair landing/ Complete Foam and Firestop / ok to insulate / received letter on girder truss bearing blocks | ERICR | ERICR | | BFR | P | 5307368 |
GOETZMANN CUSTOM HOMES, INC. | BSP | P | 09/19/2016 | Back deck frame OK | NICK | NICK | | BSP | P | 5296619 |
GOETZMANN CUSTOM HOMES, INC. | BSP | P | 09/15/2016 | deck piers ok | SCOTTS | SCOTTS | | BSP | P | 5294861 |
GOETZMANN CUSTOM HOMES, INC. | BSP | R | 09/15/2016 | missing some roll blocks on north and south sides -- need clarification on AF3/ shows bearing block by patio door but not a callout | SCOTTS | SCOTTS | | BSP | R | 5294860 |
GOETZMANN CUSTOM HOMES, INC. | BSP | P | 08/31/2016 | deck piers ok / rear porch roof framing ok / porch post ok / narrow wall framing ok | ERICR | ERICR | | BSP | P | 5282475 |
GOETZMANN CUSTOM HOMES, INC. | BFI | C | 07/14/2016 | | ERICR | ERICR | | BFI | C | 5245200 |
GOETZMANN CUSTOM HOMES, INC. | BFD | P | 07/14/2016 | received drain design use able space only / perimeter drain ok need to see drain day lighted at final | ERICR | ERICR | | BFD | P | 5245190 |
GOETZMANN CUSTOM HOMES, INC. | BFN | C | 07/14/2016 | received soils report and foundation observation letter | ERICR | ERICR | | BFN | C | 5245186 |
GOETZMANN CUSTOM HOMES, INC. | BFT | C | 07/14/2016 | Received stamped open hole and footer observation letters / received foundation design / 2000 psf | ERICR | ERICR | | BFT | C | 5245180 |
GOETZMANN CUSTOM HOMES, INC. | BFT | P | 06/23/2016 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFT | P | 5229072 |
GOETZMANN CUSTOM HOMES, INC. | BFN | P | 06/23/2016 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFN | P | 5229071 |
COLORADO SPRINGS ELECTRIC PLUS INC. | E= | C | 12/30/2016 | | JOHNN | JOHNN | | E= | C | 5379961 |
ELECTRIC PLUS | ES | C | 09/29/2016 | Residential Underground: 200 amp,new res,ok to set meter | JOHNN | JOHNN | | ES | C | 5306217 |
ELECTRIC PLUS | ER | C | 09/29/2016 | 200 amp ug,no cv,no mcc,rev ufer,3#10,1#6al,1#2al,70 amp sub panel in basement,no mcc,partial unfinished basement,low volt fire emergency system | JOHNN | JOHNN | | ER | C | 5306216 |
OLYMPIA HEATING & COOLING INC. | H= | C | 12/15/2016 | FINISHED BASEMENT, LOUVER DOOR, A/C COMPLETE | DAVIDH | DAVIDH | | H= | C | 5369411 |
PLATINUM PLUMBING INC | HC | C | 09/19/2016 | RELEASE METER | PAULO | PAULO | | HC | C | 5296655 |
PLATINUM PLUMBING INC | HI | C | 09/19/2016 | 10# TEST OK. NOTE: 1 1/4" MAIN AT 80' TO FURNACE, WATER HEATER, COOK TOP, FIRE PLACE AND FIRE PIT. | PAULO | PAULO | | HI | C | 5296650 |
OLYMPIA HEATING & COOLING INC. | HRR | C | 09/15/2016 | WHAT IS THE CFM OF THE DOWN DRAFT COOK TOP? REST OK. NOTE: FINISHED BASEMENT, INDIRECT VENT FURNACE, NO OUTSIDE AIR TO RETURN, A/C ROUGH AND LINE SET, DUCT DESIGN. | PAULO | PAULO | | HRR | C | 5294588 |
FRONTIER MECHANICAL SYSTEMS INC | P= | C | 12/13/2016 | pvb installed, finished basement. | TAYLOR | TAYLOR | | P= | C | 5366862 |
FRONTIER MECHANICAL SYSTEMS INC | PTO | C | 09/14/2016 | finished basement, VTR. | TAYLOR | TAYLOR | | PTO | C | 5292813 |
FRONTIER MECHANICAL SYSTEMS INC | PB | C | 07/21/2016 | | TAYLOR | TAYLOR | | PB | C | 5250440 |