ROBERT SCOTT GENERAL CONTRACTORS, INC. | B= | C | 05/05/2017 | | LINDSEY | LINDSEY | | B= | C | 5497386 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BLA | C | 02/28/2017 | | LINDSEY | LINDSEY | | BLA | C | 5426983 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | C | 02/21/2017 | corrections made | LINDSEY | LINDSEY | | BFR | C | 5421032 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BIN | C | 02/21/2017 | | LINDSEY | LINDSEY | | BIN | C | 5421031 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | P | 02/17/2017 | Missing nails in hardware at garage trusses // remove blocks from floating walls // repair at top flange in joist lower level // rest ok // ok to insulate | LINDSEY | LINDSEY | | BFR | P | 5419082 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | P | 01/31/2017 | front and rear porch lids ok | LINDSEY | LINDSEY | | BSP | P | 5402556 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | P | 12/29/2016 | garage portals ok | LINDSEY | LINDSEY | | BSP | P | 5379006 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFD | C | 11/08/2016 | corrections complete | ERICR | ERICR | | BFD | C | 5338613 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFD | P | 11/07/2016 | need to finish garage drain / received open hole observation | ERICR | ERICR | | BFD | P | 5337643 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFI | C | 11/07/2016 | | ERICR | ERICR | | BFI | C | 5337634 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFT | C | 10/31/2016 | | LINDSEY | LINDSEY | | BFT | C | 5331938 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFN | C | 10/31/2016 | Eufer OK / Soils report on file / Foundation design on file / pick up open hole at Drain | LINDSEY | LINDSEY | | BFN | C | 5331937 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFT | P | 10/25/2016 | Need note from engineer showing change of detail at previous walkout location // pick up paperwork at foundation | LINDSEY | LINDSEY | | BFT | P | 5326873 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFT | P | 10/20/2016 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFT | P | 5323593 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFN | P | 10/20/2016 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFN | P | 5323592 |
SERVICE FIRST ELECTRIC | E= | C | 05/04/2017 | | DEAN | DEAN | | E= | C | 5496641 |
SERVICE FIRST ELECTRIC | E= | R | 05/04/2017 | corrections not made:open splice at hood,add j box or use factory j box, | JOHNN | JOHNN | | E= | R | 5495888 |
SERVICE FIRST ELECTRIC | E= | R | 05/03/2017 | 2 rear outside outlets need gfci,open splice at hood,----------------------40 amp a/c ok | JOHNN | JOHNN | | E= | R | 5494565 |
SERVICE FIRST ELECTRIC | ER | C | 02/16/2017 | | JOHNN | JOHNN | | ER | C | 5417289 |
SERVICE FIRST ELECTRIC | ER | T | 02/15/2017 | PAID (REC#1402940) corrections not completely made,please check all thru out house, several up stairs,several down stairs,will need to add grd screw on some, fire block ok, | JOHNN | JOHNN | | ER | T | 5415642 |
SERVICE FIRST ELECTRIC | ER | R | 02/14/2017 | washer water connection box and single gang box in same stud space,needs to be boxed out,or moved,round ceiling boxes:some are missing grd screw,some the screw is not tightened down,metal fan box,grd wire not connected to grd screw,please check all thru out house,---------------------------notes:200 amp,1#10,1#6al,1#6cu,no mcc,nocv,rev ufer near panel, 100 amp sub in basement,1#6al,no mcc | JOHNN | JOHNN | | ER | R | 5414703 |
SERVICE FIRST ELECTRIC | ES | C | 02/14/2017 | Residential Underground: 200 amp,3w,new res,ok to set meter | JOHNN | JOHNN | | ES | C | 5414667 |
GENE'S HEATING AND AIR LLC | H= | C | 05/02/2017 | LOUVER DOOR, DIRECT VENT FURN, 6" OSA, A/C COMPLETE,FINISHED BASEMENT | DAVIDH | DAVIDH | | H= | C | 5493521 |
KAMPP-L ENTERPRISES, INC. | HC | C | 03/27/2017 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 5456482 |
KAMPP-L ENTERPRISES, INC. | HI+ | C | 03/10/2017 | 10 LB TEST NOTE ADDED DRYER | DAVIDH | DAVIDH | | HI+ | C | 5438112 |
KAMPP-L ENTERPRISES, INC. | HI | C | 02/15/2017 | 10 LB TEST IS OK. 1 1/4" MAIN FOR THE FURNACE, WATER HEATER, RANGE, BBQ AND 2 - FIREPLACES. | JEFFB | JEFFB | | HI | C | 5416490 |
GENE'S HEATING AND AIR LLC | HRR | C | 02/14/2017 | CORRECTIONS MADE | DAVIDH | DAVIDH | | HRR | C | 5414816 |
GENE'S HEATING AND AIR LLC | HRR | P | 02/10/2017 | REMOVE TAR PAPER FROM UPSTAIRS F/P REST OK NOTE FINISHED BASEMENT,6"OSA,A/C ROUGH | DAVIDH | DAVIDH | | HRR | P | 5412393 |
KAMPP-L ENTERPRISES, INC. | P= | C | 05/01/2017 | NOTE : FINISHED BASEMENT , PVB INSTALLED , TEMPERING AT MASTER LAV | GABE | GABE | | P= | C | 5492222 |
KAMPP-L ENTERPRISES, INC. | PTO | C | 02/14/2017 | corrections made. | TAYLOR | TAYLOR | | PTO | C | 5414918 |
KAMPP-L ENTERPRISES, INC. | PTO | P | 02/13/2017 | undersized cold water piping, need recirculating line and pump, rest ok, finished basement, aav's at bar sink, kitchen, both lavs in basement, upstairs guest bath lav. | TAYLOR | TAYLOR | | PTO | P | 5413438 |
KAMPP-L ENTERPRISES, INC. | PB | C | 11/10/2016 | | TAYLOR | TAYLOR | | PB | C | 5341584 |