ROBERT SCOTT GENERAL CONTRACTORS, INC. | B= | C | 01/09/2018 | items corrected | LONNYS | LONNYS | | B= | C | 5732548 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | B= | R | 01/04/2018 | Guards at rear deck and entry less than 36" minimum - Measure 35-35 1/2" // Finished basement / Rear deck | JUSTINL | JUSTINL | | B= | R | 5728687 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BLA | C | 09/29/2017 | Lath OK | JUSTINL | JUSTINL | | BLA | C | 5641004 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BIN | C | 09/22/2017 | | RICHB | RICHB | | BIN | C | 5634278 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | C | 09/22/2017 | Plan splice on file for changes in Master / letter received for floor framing in master shower / all other items completed | RICHB | RICHB | | BFR | C | 5634274 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | T | 09/21/2017 | PAID (REC#1454389) PLAN SPLICE FEE: $50 by: MICHAELA for Construction: Add windows | MICHAELA | MICHAELA | | BSP | T | 5632481 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | P | 09/19/2017 | Missing anchor bolts at rim at garage / Need to update plans to show added windows in master bedroom, Nook and guest suit / Missing 2 more HTS20s at TO2G rear of great room - Need total of 4 / Strap top plate in guest bathroom / Glue shims in beam pocket in basement / Need letter for drop floor framing for master bath shower / Missing point load under added window in nook / Missing anchor bolts at walk out / Complete foam and firestop / OK to insulate // NOTE: still need deck frame inspection | JUSTINL | JUSTINL | | BFR | P | 5630057 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | P | 09/12/2017 | Front porch posts OK / rear deck posts OK / plans reviewed electronically | RICHB | RICHB | | BSP | P | 5623656 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | P | 09/07/2017 | Front porch lid OK / plans reviewed electronically | RICHB | RICHB | | BSP | P | 5619000 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFT | C | 07/11/2017 | Paperwork on file | SHAUN | SHAUN | | BFT | C | 5560143 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFD | C | 07/11/2017 | Drain daylighted | SHAUN | SHAUN | | BFD | C | 5560136 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFI | C | 07/11/2017 | Foundation insulation okay | SHAUN | SHAUN | | BFI | C | 5560085 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFN | C | 07/11/2017 | Received foundation design | SHAUN | SHAUN | | BFN | C | 5560075 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFT | P | 06/13/2017 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 5533542 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFN | P | 06/13/2017 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 5533541 |
SERVICE FIRST ELECTRIC | E= | C | 11/27/2017 | final,ok , 30-amp A/C ok / | JOHNN | JOHNN | | E= | C | 5694389 |
SERVICE FIRST ELECTRIC | ES | C | 09/18/2017 | Residential Underground: 200-amp 3 Wire service, ok to set meter, new res, | JOHNN | JOHNN | | ES | C | 5628874 |
SERVICE FIRST ELECTRIC | ER | C | 09/18/2017 | rough ok,-------------------------------rev ufer, | JOHNN | JOHNN | | ER | C | 5628862 |
GENE'S HEATING AND AIR LLC | H= | C | 11/21/2017 | FINISHED BASEMENT, A/C COMPLETE, LOUVER DOOR DIRECT VENT FURN | DAVIDH | DAVIDH | | H= | C | 5691823 |
KAMPP-L ENTERPRISES, INC. | HC | C | 09/15/2017 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 5627581 |
KAMPP-L ENTERPRISES, INC. | HI | C | 09/15/2017 | 10 lb test ok note 1 furn,w/h,f/p and c/t | DAVIDH | DAVIDH | | HI | C | 5627580 |
GENE'S HEATING AND AIR LLC | HRR | C | 09/08/2017 | FINISHED BASEMENT, 6" OSA,A/C COIL ONLY, DIRECT VENT FURN | DAVIDH | DAVIDH | | HRR | C | 5620068 |
KAMPP-L ENTERPRISES, INC. | P= | C | 12/14/2017 | pvb installed, finished basement. | TAYLOR | TAYLOR | | P= | C | 5712856 |
KAMPP-L ENTERPRISES, INC. | PTO | C | 09/15/2017 | finished basement, aav's at all lavs/ sinks minus laundry sink. | TAYLOR | TAYLOR | | PTO | C | 5627058 |
KAMPP-L ENTERPRISES, INC. | PB | C | 07/14/2017 | | TAYLOR | TAYLOR | | PB | C | 5564784 |