HAMMER HOMES, INC. | B= | C | 02/01/2018 | All other required Final inspections are complete. (This is a computer generated result) | NICK | NICK | | B= | C | 5753959 | HAMMER HOMES, INC. | B= | P | 01/22/2018 | . Additional Inspections Required (computer generated): External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: City Engineering Inspections 719-385-5977), External Agency Inspection Z= by ZONING is not Completed yet (Contact: 719-385-5982). | NICK | NICK | | B= | P | 5744173 | HAMMER HOMES, INC. | BFD | C | 01/22/2018 | | NICK | NICK | | BFD | C | 5744172 | HAMMER HOMES, INC. | BLA | C | 10/16/2017 | Lath OK | JUSTINL | JUSTINL | | BLA | C | 5656602 | HAMMER HOMES, INC. | BIN | C | 09/29/2017 | Corrections made | JUSTINL | JUSTINL | | BIN | C | 5641035 | HAMMER HOMES, INC. | BFR | C | 09/29/2017 | Corrections made | JUSTINL | JUSTINL | | BFR | C | 5641023 | HAMMER HOMES, INC. | BIN | R | 09/27/2017 | Dry in not complete - Missing roof jack for dryer vent in rear bedroom, B vent pipe jack in garage and pipe cap in kitchen - Wet insulation in rear bedroom - Dry in must be complete wet insulation removed prior to calling next insulation inspection / Missing draft stop above arch at rear of stairs to basement | JUSTINL | JUSTINL | | BIN | R | 5638684 | HAMMER HOMES, INC. | BFR | T | 09/27/2017 | PAID (REC#1456074) Still missing B vent jack in garage | JUSTINL | JUSTINL | | BFR | T | 5638681 | HAMMER HOMES, INC. | BFR | P | 09/25/2017 | Still missing roof jack at B vent in garage / Other framing corrections made
| JUSTINL | JUSTINL | | BFR | P | 5635710 | HAMMER HOMES, INC. | BFR | P | 09/22/2017 | Deck framing OK / complete fireblock & draftstop / need roof jack at B vent in garage / need 3K each end at basement slider / need insulation rulers in attic / plans reviewed electronically | RICHB | RICHB | | BFR | P | 5634240 | HAMMER HOMES, INC. | BSP | P | 09/07/2017 | Front & rear porch lid framing OK / narrow wall framing at 2-car opening OK / plans reviewed electronically | RICHB | RICHB | | BSP | P | 5618981 | HAMMER HOMES, INC. | BFD | P | 07/18/2017 | Items corrected // Need to see drain have positive flow from back of house to ravine // Okay to back fill rest of foundation | SHAUN | SHAUN | | BFD | P | 5567641 | HAMMER HOMES, INC. | BFD | P | 07/14/2017 | Need to verify tie in at street // Foundation observation on file // Drain usable // Waterproofing okay | SHAUN | SHAUN | | BFD | P | 5564351 | HAMMER HOMES, INC. | BFT | C | 07/14/2017 | Seal rebar at tie beam footing, Do not back fill tie beam footing // After further review- Pier P-1 for deck not inspected at time of inspection // Footing on file | SHAUN | SHAUN | | BFT | C | 5564350 | HAMMER HOMES, INC. | BFN | C | 07/14/2017 | Foundation on file // Eufer documented // Soils on file // 1,300 psf // Float and isolate // Surface drainage 12" in first 10' | SHAUN | SHAUN | | BFN | C | 5564345 | HAMMER HOMES, INC. | BFI | C | 07/13/2017 | Foundation insulation okay | SHAUN | SHAUN | | BFI | C | 5562936 | HAMMER HOMES, INC. | BFN | P | 07/13/2017 | Need open hole, footer and foundation observation // Need foundation design | SHAUN | SHAUN | | BFN | P | 5562923 | HAMMER HOMES, INC. | BFT | P | 07/13/2017 | Need open hole, footer and foundation observation // Need foundation design | SHAUN | SHAUN | | BFT | P | 5562907 | HAMMER HOMES, INC. | BFD | P | 07/13/2017 | Need open hole and drain design // visual on drain around livable space, Not tied into street | SHAUN | SHAUN | | BFD | P | 5562897 | HAMMER HOMES, INC. | BFI | P | 06/20/2017 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFI | P | 5540579 | HAMMER HOMES, INC. | BFD | P | 06/20/2017 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFD | P | 5540578 | HAMMER HOMES, INC. | BFT | P | 06/20/2017 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFT | P | 5540577 | HAMMER HOMES, INC. | BFN | P | 06/20/2017 | AUTHORIZED INSPECTION BY ENGINEER | GITA | GITA | GITA | BFN | P | 5540576 | J2D ELECTRIC, INC. | E= | C | 12/20/2017 | 30 amp a/c,ok | JOHNN | JOHNN | | E= | C | 5718478 | J2D ELECTRIC, INC. | E= | R | 12/13/2017 | 2 outlets not working in front office and foyer, appliances not installed,a/c not connected, need blocking in mech rm,dryer and left of HWH, need test light for soffit outlet, | JOHNN | JOHNN | | E= | R | 5711323 | J2D ELECTRIC, INC. | ES | C | 09/20/2017 | Residential Underground: 200-amp 3 Wire service, ok to set meter, new res, | JOHNN | JOHNN | | ES | C | 5631257 | J2D ELECTRIC, INC. | ER | C | 09/20/2017 | rough ok----------------------------------------200 amp,rev ufer, | JOHNN | JOHNN | | ER | C | 5631255 | J2D ELECTRIC, INC. | ES | R | 09/19/2017 | not ready | JOHNN | JOHNN | | ES | R | 5630031 | J2D ELECTRIC, INC. | ER | R | 09/19/2017 | not ready | JOHNN | JOHNN | | ER | R | 5629940 | MILLER HEATING & AIR CONDITIONING, INC. | H= | C | 01/04/2018 | FINISHED BASEMENT, LOUVER DOOR , A/C | DAVIDH | DAVIDH | | H= | C | 5729384 | MILLER HEATING & AIR CONDITIONING, INC. | HC | C | 09/20/2017 | RELEASE METER | MARK | MARK | | HC | C | 5632193 | MILLER HEATING & AIR CONDITIONING, INC. | HRR | C | 09/20/2017 | Will need to verify equipment in the am. Cannot upload mechanical plans/equipment, after 23 minutes still would not upload. Rough ok. By final seal holes in return at mechanical room by final. 9/21: equipment matches. Note: Finished basement, a/c coil and line set rough, no outside air to return per plan. Has 80K Trane non direct vent furnace with ADP coil model # TG1K648D175B2205AP. Water heater is direct vent. Fireplace frame and vent ok. | MARK | MARK | | HRR | C | 5632140 | L & L GAS SHOP, LLC. | HI | C | 09/13/2017 | 10 LB TESTOK NOTE 1 1/4"LINE 1FURN,W/H,C/T,BBQ,GARAGE AND 2 F/P | DAVIDH | DAVIDH | | HI | C | 5624681 | B & L PLUMBING, INC. | P= | C | 12/21/2017 | pvb installed, finished basement. | TAYLOR | TAYLOR | | P= | C | 5720065 | B & L PLUMBING, INC. | PTO | C | 09/12/2017 | finished basement, VTR. | TAYLOR | TAYLOR | | PTO | C | 5622918 | B & L PLUMBING, INC. | PB | C | 07/25/2017 | | TAYLOR | TAYLOR | | PB | C | 5575029 |
|
|