WATERS CONSTRUCTION COMPANY INC | B= | C | 07/26/2018 | All other required Final inspections are complete. (This is a computer generated result) | NICK | NICK | | B= | C | 5915630 |
WATERS CONSTRUCTION COMPANY INC | B= | P | 07/26/2018 | . Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet, External Agency Inspection N= by WP ENGINEERING is not Completed yet. | NICK | NICK | | B= | P | 5915099 |
WATERS CONSTRUCTION COMPANY INC | BFD | C | 07/26/2018 | Eng letter of observation on file for foundation drain | NICK | NICK | | BFD | C | 5915087 |
WATERS CONSTRUCTION COMPANY INC | BIN | C | 06/01/2018 | Check attic and crawl space at final / Still need drain signed off | NICK | NICK | | BIN | C | 5861478 |
WATERS CONSTRUCTION COMPANY INC | BFR | C | 06/01/2018 | Frame items complete / Still need drain signed off | NICK | NICK | | BFR | C | 5861476 |
WATERS CONSTRUCTION COMPANY INC | BFR | P | 05/29/2018 | Need to install lateral bracing for T02 trusses / Need to install shims for trimmers throughout / Need to complete dry in of roof / Need draft stop throughout / Need to nail hangers for triple beam at deck / Drain not signed off, no RBD inspection, need Eng report | NICK | NICK | | BFR | P | 5857166 |
WATERS CONSTRUCTION COMPANY INC | BSP | P | 04/19/2018 | Front porch pier OK per design with reinforcement | NICK | NICK | | BSP | P | 5821905 |
WATERS CONSTRUCTION COMPANY INC | BFN | C | 02/08/2018 | Foundation rebar OK / Grounding rod OK / Soils on file / Drain usable / #2200psf | NICK | NICK | | BFN | C | 5761011 |
WATERS CONSTRUCTION COMPANY INC | BFT | C | 02/05/2018 | Open hole on file / States to see soils report / Foundation design on file / All footings OK / Grounding rod installed | NICK | NICK | | BFT | C | 5756936 |
REGESTER ELECTRIC | E= | C | 07/18/2018 | | JOHNN | JOHNN | | E= | C | 5907325 |
REGESTER ELECTRIC | ES | C | 06/22/2018 | Residential Underground: 200-amp 3 Wire service, ok to set meter / | TOMC | TOMC | | ES | C | 5883303 |
REGESTER ELECTRIC | EUG | C | 06/22/2018 | 4/0 urd / grd | TOMC | TOMC | | EUG | C | 5883299 |
REGESTER ELECTRIC | ER | C | 05/17/2018 | rough,ok---------------------------------ir ufer,1#6cu | JOHNN | JOHNN | | ER | C | 5848754 |
HARRIS HEATING, LLC | H= | C | 07/19/2018 | LOUVERED DOOR TO WH AND CONDITIONED CRAWLSPACE | JERRYF | JERRYF | | H= | C | 5907613 |
HARRIS HEATING, LLC | HC | C | 05/25/2018 | RELEASE METER | JON | JON | | HC | C | 5856471 |
HARRIS HEATING, LLC | HRR | C | 05/25/2018 | CHECK CRAWL SPACE VENTILATION AT FINAL. CONDENSATE DRAINS TO BE TO CODE BY FINAL. NO A/C. NO WATER HEATER AT THIS TIME, CHECK WATER HEATER VENT CONNECTOR AND COMBUSTION AIR AT FINAL. GAS LINE CAPPED AT THIS TIME | JON | JON | | HRR | C | 5856461 |
GAS BUSTERS | HI | C | 05/24/2018 | 10 lb test ok 1"line 1 furn w/h | DAVIDH | DAVIDH | | HI | C | 5854523 |
PEAK PLUMBING & HEATING, INC. | P= | C | 07/25/2018 | | SHANEN | SHANEN | | P= | C | 5913206 |
PEAK PLUMBING & HEATING, INC. | PTO | C | 05/25/2018 | Check for AAV and backwater valve for floor drain in crawlspace at final, check water heater at final | SHANEN | SHANEN | | PTO | C | 5856108 |