Plumbing | Splice 7/23/18 | A | 7/31/2018 | DALEH | DALEH | | | Plumbing | 1094914 |
Electrical | Splice 7/23/18 | A | 7/30/2018 | BERTHA | BERTHA | | | Electrical | 1094465 |
Mechanical | Splice 7/23/18 | N | 7/23/2018 | JUSTINC | JUSTINC | No new mechanical all existing. No ventilation as this will be whitebox. Will require full mechanical review at next TI | | Mechanical | 1092413 |
Construction | Splice 7/23/18 | A | 7/23/2018 | DANM | DANM | No longer part of House of Sushi (adjacent space) - separate tenant space to remain Mercantile with only 1 restroom | | Construction | 1092403 |
Electrical | Splice 7/23/18 | D | 7/23/2018 | BERTHA | BERTHA | Provide updated one-line.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1092359 |
Enumeration | Splice 7/23/18 | A | 7/23/2018 | BRENT | BRENT | Scope of work changed from Suites L & M to just Suite L | | Enumeration | 1092351 |
Out to Review | Splice 7/23/18 | / | 7/23/2018 | BECKYA | BECKYA | bill walking for now but will come back later | | Out to Review | 1092348 |
Electrical | 7/10/18 | A | 7/10/2018 | BERTHA | BERTHA | Splice to show as-built conditions per inspector's comments. | | Electrical | 1087849 |
Out to Review | 7/10/18 | / | 7/10/2018 | NELIDA | NELIDA | Marlon walking | | Out to Review | 1087832 |
Electrical | Splice 3/16/18 | A | 3/16/2018 | BERTHA | BERTHA | Revised Panel P1 location. | | Electrical | 1048092 |
Plumbing | Splice 3/16/18 | A | 3/16/2018 | DALEH | DALEH | | | Plumbing | 1048088 |
Construction | Splice 3/16/18 | A | 3/16/2018 | BPHILLIPS | BPHILLIPS | Revised floor plan back wall. | | Construction | 1048080 |
Out to Review | Original | / | 3/1/2018 | RDCUSER | RDCUSER | | | Out to Review | 1042317 |
CO Springs DRE | Original | A | 3/1/2018 | RDCUSER | RDCUSER | RTL per RMT AR DP 16-00204-A1MN18 (see full review) | | CO Springs DRE | 1042315 |
Electrical | Original | A | 2/21/2018 | SHELBY | SHELBY | | | Electrical | 1039646 |
Out to Review | Original | / | 12/13/2017 | TCRIPPEN | TCRIPPEN | with joe | | Out to Review | 1020957 |
Plumbing | Original | A | 12/13/2017 | TCRIPPEN | TCRIPPEN | okay | | Plumbing | 1020956 |
Electrical | Original | D | 12/7/2017 | SHELBY | SHELBY | Please comply with previous review comments 1 and 3. See https://www.pprbd.org/plancheck/PLCK%20Com%20Elec%20List%202016.pdf (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1019650 |
Health Dept. | Original | N | 10/4/2017 | HEALTHDEPT | HEALTHDEPT | EPCPH plan review is not required - Not applicable. RN 575-8965 | rnielsen | Health Dept. | 1001091 |
Finished Bin | Original | / | 9/25/2017 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 998482 |
Health Dept. | Original | D | 9/25/2017 | HEALTHDEPT | HEALTHDEPT | Plan review required. Please contact the health department at (719) 578-3199 option 3. RNielsen 575-8965 | rnielsen | Health Dept. | 998434 |
Health Dept. | Original | / | 9/22/2017 | | SCANNING | Location = Health Dept. by SCANNING | | Health Dept. | 997911 |
Plan Coordinator | Original | / | 9/22/2017 | | GSANDERS | Location = Plan Coordinator by GSANDERS | | Plan Coordinator | 997796 |
CO Springs DRE | Original | D | 9/22/2017 | GSANDERS | GSANDERS | Change of use in Suite L requires an update to the parking table on the development plan. Parking requirement changes from 1/200 square feet to 1/100 for restaurant. Parking is already under the requirement so administrative relief or a non-use variance will be required. Please fill out a pre-application form: https://coloradosprings.gov/planning/webform/pre-application-meeting-request (see full review) | | CO Springs DRE | 997795 |
Hazmat | Original | N | 9/20/2017 | CSFIRE | CSFIRE | | rpeterson | Hazmat | 997193 |
CO Springs Fire | Original | A | 9/20/2017 | CSFIRE | CSFIRE | | rpeterson | CO Springs Fire | 997190 |
Water Division | Original | N | 9/20/2017 | CSUREVIEW | CSUREVIEW | No utility work proposed outside the building. JPN | jnoble | Water Division | 997158 |
Waste Water Div | Original | N | 9/20/2017 | CSUREVIEW | CSUREVIEW | No utility work proposed outside the building. JPN | jnoble | Waste Water Div | 997156 |
Mechanical | Original | A | 9/19/2017 | DALEH | DALEH | | | Mechanical | 996676 |
Construction | Original | A | 9/19/2017 | DANM | DANM | | | Construction | 996674 |
Electrical | Original | D | 9/19/2017 | BERTHA | BERTHA | 1. Provide complete one-line diagram. 2. Provide AIC rating of new Panel P1 3. Provide Available Fault Current at new Panel P1.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 996668 |
Plumbing | Original | D | 9/19/2017 | TCRIPPEN | TCRIPPEN | provide an water pipe size analysis data on plans , schedule water pipe and DWV material on plans (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 996655 |
Construction | Original | D | 9/18/2017 | BPHILLIPS | BPHILLIPS | Clarify occupant load calculations. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 996471 |
Enumeration | Original | A | 9/18/2017 | BRENT | BRENT | | | Enumeration | 996343 |
Floodplain | Original | N | 9/18/2017 | BRENT | BRENT | | | Floodplain | 996342 |
Out to Review | Original | / | 9/18/2017 | NELIDA | NELIDA | Bill walking 719-209-0073 | | Out to Review | 996318 |