Out to Review | Original | / | 5/16/2018 | MATTHEWM | MATTHEWM | Contractor 7196470463 | | Out to Review | 1069311 |
Scanned/Finished Bin | Original | / | 5/4/2018 | | SCANNING | Location = Scanned/Finished Bin by SCANNING | | Scanned/Finished Bin | 1064935 |
Waste Water Div | Original | A | 5/4/2018 | SCANNING | SCANNING | | | Waste Water Div | 1064832 |
Water Division | Original | A | 5/4/2018 | SCANNING | SCANNING | | | Water Division | 1064831 |
Hazmat | Original | N | 5/4/2018 | SCANNING | SCANNING | | | Hazmat | 1064830 |
County Fire | Original | A | 5/4/2018 | SCANNING | SCANNING | | | County Fire | 1064829 |
To Be Scanned Bin | Original | / | 5/3/2018 | | SCANNING | Location = To Be Scanned Bin by SCANNING | | To Be Scanned Bin | 1064779 |
Health Dept. | Original | N | 5/3/2018 | HEALTHDEPT | HEALTHDEPT | Not applicable | Jzimmerman | Health Dept. | 1064618 |
Health Dept. | Original | / | 5/3/2018 | | SCANNING | Location = Health Dept. by SCANNING | | Health Dept. | 1064403 |
Fire | Original | / | 5/3/2018 | | SCANNING | Location = Fire by SCANNING - Fire / Hazmat / Waste & Waste Water signed off on plan to verify at permitting, per Matt. . . - J3- | | Fire | 1064313 |
Plan Coordinator | Original | / | 5/1/2018 | | SHELBY | Location = Plan Coordinator by SHELBY | | Plan Coordinator | 1063582 |
Electrical | Original | A | 5/1/2018 | SHELBY | SHELBY | | | Electrical | 1063581 |
Electrical | Original | / | 4/30/2018 | SHELBY | SHELBY | In Current Review by SHELBY | | Electrical | 1062865 |
Electrical | Original | / | 4/24/2018 | | MATTHEWM | Location = Electrical by MATTHEWM | | Electrical | 1061071 |
Resubmittal 3 | Original | / | 4/24/2018 | MATTHEWM | MATTHEWM | Resubmittal #3 | | Resubmittal 3 | 1061070 |
Out to Review | Original | / | 4/9/2018 | JANE | JANE | Steve 719 475 2935 | | Out to Review | 1055302 |
Finished Bin | Original | / | 4/9/2018 | | JANE | Location = Finished Bin by JANE | | Finished Bin | 1055224 |
Plan Coordinator | Original | / | 4/9/2018 | | TCRIPPEN | Location = Plan Coordinator by TCRIPPEN | | Plan Coordinator | 1055170 |
Plumbing | Original | N | 4/9/2018 | TCRIPPEN | TCRIPPEN | See alternate M&M no plumbing work issue no permit. | | Plumbing | 1055169 |
Plumbing | Original | / | 4/9/2018 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Plumbing | 1055162 |
Plumbing | Original | / | 4/6/2018 | | SCANNING | Location = Plumbing by SCANNING | | Plumbing | 1054733 |
Plan Coordinator | Original | / | 4/5/2018 | | SHELBY | Location = Plan Coordinator by SHELBY | | Plan Coordinator | 1054679 |
Electrical | Original | D | 4/5/2018 | SHELBY | SHELBY | 1. Indicate clearly this scope of work( Canopy and service are in/on a separate structure which would require q separate permit). 2. Comply 225.31 and 225.32 NEC. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1054678 |
Resubmittal 2 | Original | / | 4/3/2018 | GITA | GITA | Resubmittal #2 | | Resubmittal 2 | 1053422 |
Mechanical | Original | A | 3/30/2018 | JUSTINC | JUSTINC | See sheet 23 for EUH 1,2 See sheet 29 for Sf-1,2 and LD -1,2 | | Mechanical | 1052684 |
Out to Review | Original | / | 3/30/2018 | NELIDA | NELIDA | Mark Morton 719-475-2935 | | Out to Review | 1052416 |
Finished Bin | Original | / | 3/28/2018 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 1051339 |
County Zoning | Original | A | 3/28/2018 | DSDRANGEL | DSDRANGEL | INSPECTION REQUIRED | | County Zoning | 1051298 |
Zoning/Planning | Original | / | 3/28/2018 | | SCANNING | Location = Zoning/Planning by SCANNING | | Zoning/Planning | 1051278 |
CSU Contract Admin. | Original | / | 3/28/2018 | | SCANNING | Location = CSU Contract Admin. by SCANNING - CSU Contract Admin Determined this address is not in their juristiction. | | CSU Contract Admin. | 1051241 |
Zoning/Planning | Original | / | 3/28/2018 | | SCANNING | Location = Zoning/Planning by SCANNING | | Zoning/Planning | 1051237 |
CSU Contract Admin. | Original | / | 3/28/2018 | | SCANNING | Location = CSU Contract Admin. by SCANNING | | CSU Contract Admin. | 1051110 |
Plan Coordinator | Original | / | 3/28/2018 | | TCRIPPEN | Location = Plan Coordinator by TCRIPPEN | | Plan Coordinator | 1051074 |
Plumbing | Original | D | 3/28/2018 | TCRIPPEN | TCRIPPEN | plumbing comments not addressed you may have to apply for an variance or alternate method variance ///// see Alternate Methed in Images///// (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 1051073 |
Plumbing | Original | / | 3/27/2018 | | SCANNING | Location = Plumbing by SCANNING | | Plumbing | 1050743 |
Plan Coordinator | Original | / | 3/27/2018 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 1050712 |
Mechanical | Original | D | 3/27/2018 | JUSTINC | JUSTINC | Comment from 1st review not addressed? Provide (M) "mechanical sheet indicating all associated mechanical scope associated with this permit.
MECHANICAL REVIEW INCOMPLETE
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1050711 |
Mechanical | Original | / | 3/26/2018 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Mechanical | 1050540 |
Mechanical | Original | / | 3/26/2018 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1050398 |
Plan Coordinator | Original | / | 3/26/2018 | | SHELBY | Location = Plan Coordinator by SHELBY | | Plan Coordinator | 1050356 |
Electrical | Original | D | 3/26/2018 | SHELBY | SHELBY | 1. Please remove all electrical work that is not part of this scope from drawings. 2. Provide complete electrical for this scope. See https://www.pprbd.org/Downloads/CommercialHandout/Com%20Elect%20reqs.pdf (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1050355 |
Electrical | Original | / | 3/21/2018 | SHELBY | SHELBY | In Current Review by SHELBY | | Electrical | 1049129 |
Electrical | Original | / | 3/16/2018 | | MATTHEWM | Location = Electrical by MATTHEWM | | Electrical | 1048043 |
Resubmittal 1 | Original | / | 3/16/2018 | MATTHEWM | MATTHEWM | Resubmittal #1 | | Resubmittal 1 | 1048041 |
Out to Review | Original | / | 2/9/2018 | RITA | RITA | Steve 719-4752935 | | Out to Review | 1036185 |
Electrical | Original | / | 2/7/2018 | | SCANNING | Location = Electrical by SCANNING | | Electrical | 1035597 |
Plan Coordinator | Original | / | 2/7/2018 | | DALEH | Location = Plan Coordinator by DALEH | | Plan Coordinator | 1035509 |
Mechanical | Original | D | 2/7/2018 | DALEH | DALEH | provide separate M-sheets showing complete mechanical scope of work. no review no walk (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1035508 |
Mechanical | Original | / | 2/7/2018 | DALEH | DALEH | In Current Review by DALEH | | Mechanical | 1035501 |
Mechanical | Original | / | 2/7/2018 | | DALEH | Location = Mechanical by DALEH | | Mechanical | 1035500 |
Plumbing | Original | D | 2/6/2018 | TCRIPPEN | TCRIPPEN | How are you complying with the required rest room. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 1035121 |
Electrical | Original | / | 2/6/2018 | | SCANNING | Location = Electrical by SCANNING | | Electrical | 1034962 |
Plan Coordinator | Original | / | 2/6/2018 | | MICHAELA | Location = Plan Coordinator by MICHAELA | | Plan Coordinator | 1034907 |
Construction | Original | A | 2/6/2018 | MICHAELA | MICHAELA | | | Construction | 1034906 |
Construction | Original | / | 2/5/2018 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Construction | 1034633 |
Construction | Original | / | 2/1/2018 | | SCANNING | Location = Construction by SCANNING | | Construction | 1034100 |
Plan Coordinator | Original | / | 2/1/2018 | | BRENT | Location = Plan Coordinator by BRENT | | Plan Coordinator | 1034071 |
Enumeration | Original | A | 2/1/2018 | BRENT | BRENT | | | Enumeration | 1034070 |
Floodplain | Original | N | 1/29/2018 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6132001024) | | Floodplain | 1032342 |