Mechanical | Original | A | 4/17/2018 | JUSTINC | JUSTINC | | | Mechanical | 1058053 |
Plumbing | Original | A | 4/17/2018 | TCRIPPEN | TCRIPPEN | okay | | Plumbing | 1058045 |
Electronic Plan | Original | / | 4/17/2018 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Electronic Plan | 1058040 |
Resubmittal 2 | Original | / | 4/16/2018 | BECKYA | BECKYA | Resubmittal #2 | | Resubmittal 2 | 1057552 |
CO Springs Fire | Original | A | 3/26/2018 | CSFIRE | CSFIRE | Submitted By: Peterson, Roland Thomas (see full review) | csfdit | CO Springs Fire | 1050396 |
Health Dept. | Original | A | 3/20/2018 | HEALTHDEPT | HEALTHDEPT | Approved in plan review. A pre-operational inspection will be required before final approval for opening is granted. | Aparikh | Health Dept. | 1048853 |
Plumbing | Original | D | 3/20/2018 | TCRIPPEN | TCRIPPEN | See section 802.3.1 for receptor sizes and 802.1.1 separate drain lines required from each bowl please provide a detail of this for plumbers, (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 1048798 |
Electronic Plan | Original | / | 3/20/2018 | TCRIPPEN | TCRIPPEN | In Current Review by TCRIPPEN | | Electronic Plan | 1048734 |
Waste Water Div | Original | A | 3/19/2018 | CSUREVIEW | CSUREVIEW | No apparent conflicts. RDS | rsolberg | Waste Water Div | 1048410 |
Gas/Elec. Utils | Original | A | 3/19/2018 | CSUREVIEW | CSUREVIEW | No apparent conflicts. RDS | rsolberg | Gas/Elec. Utils | 1048409 |
Health Dept. | Original | D | 3/19/2018 | HEALTHDEPT | HEALTHDEPT | Retail food establishment plan review required. Information and application may be accessed online at https://www.elpasocountyhealth.org/service/retail-food-establishment-licensing-0 For questions contact Environmental Health at 719-578-3199 option 3. | rnielsen | Health Dept. | 1048318 |
Mechanical | Original | A | 3/19/2018 | JUSTINC | JUSTINC | | | Mechanical | 1048242 |
Construction | Original | A | 3/19/2018 | DANM | DANM | | | Construction | 1048167 |
Electronic Plan | Original | / | 3/19/2018 | DANM | DANM | In Current Review by DANM | | Electronic Plan | 1048158 |
Enumeration | Original | A | 3/16/2018 | BRENT | BRENT | | | Enumeration | 1047774 |
Resubmittal 1 | Original | / | 3/16/2018 | BECKYA | BECKYA | Resubmittal #1 | | Resubmittal 1 | 1047699 |
CO Springs DRE | Original | A | 3/1/2018 | MPFITZSIMMONS | MPFITZSIMMONS | The plans substantially match DP plans, Approved Parking lot configuration is not the same as the approved DP, but this plan is only for the interior remodel. (see full review) | | CO Springs DRE | 1042289 |
CSU Contract Admin. | Original | A | 2/27/2018 | CSUAPPSPRM | CSUAPPSPRM | Commercial water meter sizing form approved and applicable development charges and fees paid 2/27/2018 MKL | mkluke | CSU Contract Admin. | 1041257 |
Electrical | Original | A | 2/22/2018 | BERTHA | BERTHA | | | Electrical | 1040167 |
Hazmat | Original | N | 2/21/2018 | CSFIRE | CSFIRE | Sheet A003 indicates only 70# CO2 to be provided. | dwithee | Hazmat | 1039408 |
CO Springs Fire | Original | D | 2/21/2018 | CSFIRE | CSFIRE | reference review report online for disapproval comments (see full review) | csfdit | CO Springs Fire | 1039403 |
Mechanical | Original | D | 2/20/2018 | JUSTINC | JUSTINC | Add note: Provide (1) copy of test and balance report to mechanical inspector at time of heating final inspection. Relocate all Captiveaire sheets to (M) sheets for review
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1039286 |
Zoning/Planning | Original | / | 2/20/2018 | MPFITZSIMMONS | MPFITZSIMMONS | In Current Review by MFITZSIMMONS | | Zoning/Planning | 1038870 |
Water Division | Original | A | 2/16/2018 | CSUREVIEW | CSUREVIEW | | mlwilliams | Water Division | 1038577 |
Waste Water Div | Original | D | 2/16/2018 | CSUREVIEW | CSUREVIEW | A variance is required for this unit. The grease interceptor is located more than 50' from the last grease waste fixture. Contact Bryan Kurth at 719.668.4420 to discuss. MLW | mlwilliams | Waste Water Div | 1038574 |
Gas/Elec. Utils | Original | D | 2/16/2018 | CSUREVIEW | CSUREVIEW | Contact CSU Field Engineer, DeeDee Brook at 719.668.4510 to discuss gas load and gas meter for this unit. MLW | mlwilliams | Gas/Elec. Utils | 1038572 |
CSU Contract Admin. | Original | D | 2/16/2018 | CSUAPPSPRM | CSUAPPSPRM | Requires approved Commercial Water Meter Sizing Form (CWMSF) and payment of utility charges and fees. Please contact Utilities Development Services at 719-668-7467 for questions, assistance or to request an estimate.
CWMSF available online at: https://www.csu.org/CSUDocuments/commercialwatermetersizingform.pdf
MKL | mkluke | CSU Contract Admin. | 1038348 |
Plumbing | Original | D | 2/15/2018 | TCRIPPEN | TCRIPPEN | provide an water an water pipe size analysis data on plns (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 1038255 |
City Engr | Original | N | 2/15/2018 | JDAGNILLO | JDAGNILLO | | | City Engr | 1038234 |
Health Dept. | Original | D | 2/15/2018 | HEALTHDEPT | HEALTHDEPT | Retail food establishment plan review required. Information and application may be accessed online at https://www.elpasocountyhealth.org/service/retail-food-establishment-licensing-0 For questions contact Environmental Health at 719-578-3199 option 3. | rnielsen | Health Dept. | 1038091 |
Construction | Original | D | 2/15/2018 | DANM | DANM | Identify doors receiving panic hardware on door schedule Clarify finish material at toilet side wall and if meeting IBC 1210 for surrounding materials
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1038085 |
Electronic Plan | Original | / | 2/14/2018 | DANM | DANM | In Current Review by DANM | | Electronic Plan | 1037690 |
Enumeration | Original | D | 2/9/2018 | BRENT | BRENT | Address for this project is 1634 S. Nevada Ave. Correct all plan pages, code study form and electronic submittal to show this address. Include the secondary addressing. Secondary addressing established by the plan for the core and shell for this building. Tax schedule number shown on code study form is incorrect. Tax schedule number and legal description to be updated by assessor. Include a site plan showing all tenant spaces in the building with addressing shown and area of work highlighted. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Enumeration | 1036445 |
Floodplain | Original | A | 2/9/2018 | BRENT | BRENT | permit 17084 | | Floodplain | 1036440 |
Floodplain | Original | / | 2/7/2018 | RBD GIS | RBD GIS | Autogenerated Review: Parcel intersects with 100 Year Floodplain. (Parcel: 6430201003) | | Floodplain | 1035562 |