Scanned/Finished Bin | Original | / | 11/20/2015 | | KENYATTA | Location = Scanned/Finished Bin by KENYATTA | | Scanned/Finished Bin | 831451 |
To Be Scanned Bin | Original | / | 11/19/2015 | | REBECCA | Location = To Be Scanned Bin by REBECCA | | To Be Scanned Bin | 831264 |
WP Fire | Original | A | 11/19/2015 | DBURGESS | DBURGESS | Per Fire Marshal Vernon Champlin | | WP Fire | 831204 |
WP Floodplain | Original | N | 11/19/2015 | DBURGESS | DBURGESS | Per Sally Riley | | WP Floodplain | 831202 |
WP Zoning | Original | A | 11/19/2015 | DBURGESS | DBURGESS | Per Sally Riley | | WP Zoning | 831201 |
WP Floodplain | Original | N | 11/19/2015 | DBURGESS | DBURGESS | | | WP Floodplain | 831199 |
Electrical | Original | A | 11/19/2015 | SHELBY | SHELBY | | | Electrical | 831155 |
Out to Review | Original | / | 11/18/2015 | SHELBY | SHELBY | | | Out to Review | 831067 |
Electrical | Original | D | 11/18/2015 | SHELBY | SHELBY | 1.Comply 230.6 NEC for note 20 E101. 2. For meter taps comply 240.21 NEC | | Electrical | 831066 |
Construction | Original | A | 11/18/2015 | JIMA | JIMA | | | Construction | 831045 |
Woodland Park | Original | / | 10/23/2015 | | DBURGESS | Location = Woodland Park by DBURGESS - issued to Lane with CMS for revs. Given to Keith with WP for review. | | Woodland Park | 825323 |
Woodland Park Bin | Original | / | 10/21/2015 | | RITA | Location = Woodland Park Bin by RITA | | Woodland Park Bin | 824510 |
Plan Coordinator | Original | / | 10/21/2015 | | DOUG | Location = Plan Coordinator by DOUG | | Plan Coordinator | 824480 |
Electrical | Original | D | 10/21/2015 | DOUG | DOUG | See previous comments. No changes submitted. | | Electrical | 824479 |
Electrical | Original | / | 10/21/2015 | DOUG | DOUG | In Current Review by DOUG | | Electrical | 824473 |
Electrical | Original | / | 10/21/2015 | | RITA | Location = Electrical by RITA | | Electrical | 824396 |
Plan Coordinator | Original | / | 10/20/2015 | | JIMA | Location = Plan Coordinator by JIMA | | Plan Coordinator | 824384 |
Construction | Original | D | 10/20/2015 | JIMA | JIMA | see plans pages which i have circled in green pen / walk only with jim a / make all corrections and supply all required trex elevations details sheets which APPLY to the deck and dock connections // The corrections to pages C10 guard rails no revised – corrections for pages not completed, L5 and L6 with trex decking you need to supply all the trex details for ledger connections, joist connections, post to beam, beam to post, hanger and hanger connections, type and size of screws for all connections. | | Construction | 824383 |
Construction | Original | / | 10/19/2015 | JIMA | JIMA | In Current Review by JIMA | | Construction | 823885 |
Construction | Original | / | 10/16/2015 | | BPHILLIPS | Location = Construction by BPHILLIPS | | Construction | 823603 |
Resubmittal 1 | Original | / | 10/16/2015 | BPHILLIPS | BPHILLIPS | Resubmittal #1 10/16/15 | | Resubmittal 1 | 823602 |
Out to Review | Original | / | 9/30/2015 | DBURGESS | DBURGESS | Rob Foster with CMS (GC) has plans for revision / further review with PPRBD. | | Out to Review | 819749 |
Woodland Park | Original | / | 9/30/2015 | | DBURGESS | Location = Woodland Park by DBURGESS | | Woodland Park | 819650 |
Woodland Park Bin | Original | / | 9/25/2015 | | KENYATTA | Location = Woodland Park Bin by KENYATTA | | Woodland Park Bin | 818945 |
Plan Coordinator | Original | / | 9/25/2015 | | DOUG | Location = Plan Coordinator by DOUG | | Plan Coordinator | 818912 |
Electrical | Original | D | 9/25/2015 | DOUG | DOUG | 1. Provide permit note similar to that written in on E101 2. Landing lug gutters not listed as service entrance gear. 3. Clarify what service equipment is installed on each structure. Include meter location. | | Electrical | 818911 |
Electrical | Original | / | 9/24/2015 | DOUG | DOUG | In Current Review by DOUG | | Electrical | 818482 |
Electrical | Original | / | 9/24/2015 | | RITA | Location = Electrical by RITA | | Electrical | 818347 |
Plan Coordinator | Original | / | 9/24/2015 | | JIMA | Location = Plan Coordinator by JIMA | | Plan Coordinator | 818338 |
Construction | Original | D | 9/24/2015 | JIMA | JIMA | see plans / no walk title page -- provide soils report and reference report on all plans / pg C10 - guard rail height min 42" -- retaining wall require separate permit / pg L4 -- shows future arbor ( not reviewed, no plan for it separate permit when ready) / L5 -- guard rail min 42" - provide metal deck framing and dock framing for all connections / L6 -- bolt spacing at ledgers, details for metal framing connections / D5 -- guard height / on all structural plans, wrong wind speed ( 100 mph ) - min roof live loads and dead loads ( 40 L - 27 D ) / on ( 3 ) of the plans and structural calc's and the plan and the code study form, the occupancy type needs to be changed to " B " occ. / SEE PLANS FOR ALL NOTES | | Construction | 818337 |
Construction | Original | / | 9/23/2015 | JIMA | JIMA | In Current Review by JIMA | | Construction | 817891 |
Construction | Original | / | 9/22/2015 | | MINDY | Location = Construction by MINDY | | Construction | 817648 |