Construction | 11/1/2018 | A | 11/1/2018 | MICHAELA | MICHAELA | Add windows | | Construction | 1126420 |
Out to Review | Splice 8/10/18 | / | 8/14/2018 | JANE | JANE | | | Out to Review | 1099661 |
Scanned/Finished Bin | Splice 8/10/18 | / | 8/10/2018 | | SCANNING | Location = Scanned/Finished Bin by SCANNING | | Scanned/Finished Bin | 1099085 |
To Be Scanned Bin | Splice 8/10/18 | / | 8/10/2018 | | SCANNING | Location = To Be Scanned Bin by SCANNING | | To Be Scanned Bin | 1098884 |
Plan Coordinator | Splice 8/10/18 | / | 8/10/2018 | | SHELLEY | Location = Plan Coordinator by SHELLEY | | Plan Coordinator | 1098855 |
Construction | Splice 8/10/18 | A | 8/10/2018 | SHELLEY | SHELLEY | Several dimension and floor plan changes. | | Construction | 1098854 |
Construction | Splice 8/10/18 | / | 8/10/2018 | SHELLEY | SHELLEY | In Current Review by SHELLEY | | Construction | 1098814 |
Construction | Splice 8/10/18 | / | 8/10/2018 | | BECKYA | Location = Construction by BECKYA | | Construction | 1098766 |
Scanned/Finished Bin | Original | / | 4/26/2018 | | SCANNING | Location = Scanned/Finished Bin by SCANNING | | Scanned/Finished Bin | 1062025 |
To Be Scanned Bin | Original | / | 4/26/2018 | | SHELLEY | Location = To Be Scanned Bin by SHELLEY | | To Be Scanned Bin | 1061922 |
Construction | Original | A | 4/26/2018 | SHELLEY | SHELLEY | ok | | Construction | 1061920 |
CO Springs Fire | Original | A | 4/23/2018 | CSFIRE | CSFIRE | | dwithee | CO Springs Fire | 1060467 |
Out to Review | Original | / | 4/23/2018 | RITA | RITA | Brad 719-491-0715 | | Out to Review | 1060462 |
Fire | Original | / | 4/10/2018 | | KHYLLESTED | Location = Fire by KHYLLESTED | | Fire | 1055915 |
CO Springs DRE | Original | A | 4/10/2018 | KHYLLESTED | KHYLLESTED | All development standards met. Rebuild on existing foundation and floor. Existing grades will not change, there will be no earth disturbance (as this term is defined by the City) associated with this project due to the fact that it is a rebuild on existing foundation and no grading will occur. (see full review) | | CO Springs DRE | 1055914 |
Zoning/Planning | Original | / | 4/4/2018 | | SCANNING | Location = Zoning/Planning by SCANNING | | Zoning/Planning | 1053849 |
Plan Coordinator | Original | / | 4/4/2018 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 1053808 |
Mechanical | Original | A | 4/4/2018 | JUSTINC | JUSTINC | | | Mechanical | 1053807 |
Mechanical | Original | / | 4/4/2018 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Mechanical | 1053617 |
Mechanical | Original | / | 4/2/2018 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1052883 |
Plan Coordinator | Original | / | 4/2/2018 | | SHELLEY | Location = Plan Coordinator by SHELLEY | | Plan Coordinator | 1052776 |
Construction | Original | D | 4/2/2018 | SHELLEY | SHELLEY | Missing bearing members and supporting elements for porches; M02E requires solid bottom chord bearing; F5G missing supporting connection; label girders for number of plies and bearing chord material; see plans; walk ok. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1052774 |
Construction | Original | / | 4/2/2018 | SHELLEY | SHELLEY | In Current Review by SHELLEY | | Construction | 1052734 |
Construction | Original | / | 3/30/2018 | | RITA | Location = Construction by RITA | | Construction | 1052453 |
Resubmittal 1 | Original | / | 3/30/2018 | RITA | RITA | Resubmittal #1 | | Resubmittal 1 | 1052452 |
Out to Review | Original | / | 2/15/2018 | NELIDA | NELIDA | Brad Houghton 719-491-0715 | | Out to Review | 1038183 |
Finished Bin | Original | / | 2/15/2018 | | SCANNING | Location = Finished Bin by SCANNING | | Finished Bin | 1038071 |
Plan Coordinator | Original | / | 2/15/2018 | | KHYLLESTED | Location = Plan Coordinator by KHYLLESTED | | Plan Coordinator | 1038057 |
CO Springs DRE | Original | D | 2/15/2018 | KHYLLESTED | KHYLLESTED | 1). This site is in the hillside overlay and requires a hillside site plan along with hillside height calculated elevations - the HS site plan checklist and HS height calculation guide is included in roll set. 2.) Any disturbance in the hillside overlay also requires a grading and erosion control plan that must be submitted to the City Water Resources Engineering Department to Jonathan Scherer at jscherer@springsgov.com. Please contact Jonathan with questions about this requirement at 719-385-5546. The grading and erosion control plan checklist is included in roll set. 3.) This parcel is located west of I-25, and a geologic hazard report or geologic hazard waiver is required.This site does not lie within the landslide susceptibility area and will be eligible for a geologic hazard waiver if this parcel does not exhibit any of the following characteristics: 1. Slopes greater than 33% percent 2. Underground mining or subsidence activity 3. A history of landfill or uncontrolled or undocumented fill activity IF the criteria outlined above is met, the site is eligible for a geologic hazard waiver application. The application needs to be signed by a professional geologist or geotechnical engineer AND it must be accompanied by a letter that states this site does not exhibit any of the characteristics noted above (also outlined on the application).
There is not a review fee for geohazard waiver applications. Once you have the letter from a geotechnical engineer or geologist, please email the following to khyllested@springsgov.com: 1. The letter 2. The signed application 3. Your site plan As long as your property meets the three criteria above, city engineering and city planning will be able to sign off on the application and then you’ll be able to submit your site plan and waiver to regional building. Wait until you have all three signatures on the geologic hazard waiver application before you submit your site plan for a building permit. Site plans that do not have a signed copy of the application will be denied.
Please contact Katelyn Hyllested at khyllested@springsgov.com with questions. (see full review) | | CO Springs DRE | 1038056 |
Zoning/Planning | Original | / | 2/14/2018 | KHYLLESTED | KHYLLESTED | In Current Review by KHYLLESTED | | Zoning/Planning | 1037464 |
Zoning/Planning | Original | / | 2/13/2018 | | SCANNING | Location = Zoning/Planning by SCANNING | | Zoning/Planning | 1037124 |
Plan Coordinator | Original | / | 2/13/2018 | | JUSTINC | Location = Plan Coordinator by JUSTINC | | Plan Coordinator | 1037029 |
Mechanical | Original | D | 2/13/2018 | JUSTINC | JUSTINC | MECHANICAL REVIEW INCOMPLETE
Missing heat loss calculations Duct design image is too light it appears some elements did not scan?
NO WALK
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1037028 |
Mechanical | Original | / | 2/12/2018 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Mechanical | 1036953 |
Mechanical | Original | / | 2/12/2018 | | SCANNING | Location = Mechanical by SCANNING | | Mechanical | 1036790 |
Plan Coordinator | Original | / | 2/12/2018 | | SHELLEY | Location = Plan Coordinator by SHELLEY | | Plan Coordinator | 1036725 |
Construction | Original | D | 2/12/2018 | SHELLEY | SHELLEY | LIMITED STRUCTURAL REVIEW - specify all loading criteria; all handwritten notes must have initial of design professional; provide statement from PE indicating existing foundation and floor framing is in good condition and suitable to support new construction; label all trusses; label all headers with kings and trimmers; clarify floor framing system as joists specified but floor trusses provided; provide connection detail at front low roof; clarify beam support; clarify deck framing; see plans; no walk. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1036724 |
Construction | Original | / | 2/12/2018 | SHELLEY | SHELLEY | In Current Review by SHELLEY | | Construction | 1036678 |
Construction | Original | / | 2/2/2018 | | BECKYA | Location = Construction by BECKYA | | Construction | 1034356 |
Floodplain | Original | N | 2/2/2018 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 7403112032) | | Floodplain | 1034314 |