Canceled Plans | Original | / | 7/25/2024 | ADMIN | ADMIN | Electronic Plan automatically cancelled due to inactivity. | | Canceled Plans | 2037143 |
Plumbing | Original | D | 7/25/2023 | SHANEN | SHANEN | Per CSU comments, approved utility service plans required. Plumbing plans must correspond with approved utility service plans. 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Plumbing | 1874683 |
Elevators | Original | D | 7/24/2023 | ROBERTV | ROBERTV | Need to provide Vertical Platform Lift Submittals . 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Elevators | 1874664 |
CSU Water | Original | D | 7/24/2023 | CSUREVIEW | CSUREVIEW | Refer to 2023 Colorado Springs Utilities WaterLESS details B4-1 through B4-8 and select the correct meter detail to include on the plumbing plans after approval of the Commercial Water Meter Sizing Form. Also refer to details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans.MDA | malcuran | CSU Water | 1874354 |
CSU Waste Water | Original | D | 7/24/2023 | CSUREVIEW | CSUREVIEW | Requires an updated utility service plan (USP) to show the additional sediment trap and waste line exterior to the building. MDA. | malcuran | CSU Waste Water | 1874352 |
Submittal 6 | Original | / | 7/23/2023 | SHELLEY | SHELLEY | Submittal #6 | | Submittal 6 | 1873967 |
CO Springs DRE | Original | A | 5/1/2023 | MALCURAN | MALCURAN | Approved per plans date stamped 10/24/2022 under CPC ZC 22-00087 & CPC DP 22-00088. Please contact City Planning when the final Zoning on-site inspection is ready.....MDA... | | CO Springs DRE | 1837596 |
Plumbing | Original | D | 3/3/2023 | SHANEN | SHANEN | CSU comments must be addressed. PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Plumbing | 1810249 |
CSU Water | Original | D | 3/3/2023 | CSUREVIEW | CSUREVIEW | See previous comments. mjg | mgackle | CSU Water | 1810162 |
CSU Waste Water | Original | D | 3/3/2023 | CSUREVIEW | CSUREVIEW | See previous comments. mjg | mgackle | CSU Waste Water | 1810161 |
Zoning/Planning | Original | / | 3/3/2023 | MALCURAN | MALCURAN | In Current Review by MALCURAN | | Zoning/Planning | 1810156 |
Elevators | Original | D | 3/3/2023 | ERIC | ERIC | Vertical Platform Lift submittals are missing from this plan set. . PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Elevators | 1810136 |
Submittal 5 | Original | / | 3/3/2023 | KALLISTAJ | KALLISTAJ | Submittal #5 | | Submittal 5 | 1810079 |
CO Springs DRE | Original | D | 2/21/2023 | MALCURAN | MALCURAN | Disapproved. Please confirm if PLDO fees have been paid per CPC DP 22-00088. Please contact matthew.alcuran@coloradosprings.gov for questions. | | CO Springs DRE | 1805197 |
Mechanical | Original | A | 2/14/2023 | JUSTINC | JUSTINC | | | Mechanical | 1802576 |
CO Springs Fire | Original | A | 2/14/2023 | CSFIRE | CSFIRE | We are pleased to inform you this plan is approved You are responsible for reviewing the APPROVAL comments found on the CSFD website as they contain important inspection information: https://web1.coloradosprings.gov/PreventionPlanReview/FPS_WebFPS.asp PLEASE ALLOW UP TO AN HOUR FOR COMMENTS TO LOAD TO THE SERVERS – NOTE COMMENTS ARE AVAILABLE FOR 30 DAYS! ALL PLAN APPROVALS SUBJECT TO FINAL INSPECTION! | dwithee | CO Springs Fire | 1807384 |
Electrical | Original | A | 2/10/2023 | DANIELG | DANIELG | | | Electrical | 1801727 |
Electronic Plan | Original | / | 2/10/2023 | DANIELG | DANIELG | In Current Review by DANIELG | | Electronic Plan | 1801712 |
CSU Waste Water | Original | D | 2/10/2023 | CSUREVIEW | CSUREVIEW | See previous comments. CM | CoreyM | CSU Waste Water | 1801598 |
CSU Water | Original | D | 2/10/2023 | CSUREVIEW | CSUREVIEW | See previous comments. CM | CoreyM | CSU Water | 1801597 |
Elevators | Original | A | 2/10/2023 | ERIC | ERIC | Garaventa Vertical Platform Lift
Emergency Phone Required | | Elevators | 1801529 |
Zoning/Planning | Original | / | 2/10/2023 | MALCURAN | MALCURAN | In Current Review by MALCURAN | | Zoning/Planning | 1801484 |
Construction | Original | A | 2/10/2023 | SHELLEY | SHELLEY | | | Construction | 1801381 |
Plumbing | Original | D | 2/9/2023 | SHANEN | SHANEN | CSU and construction review comments, if any, must be addressed. P0.1: Provide code section requiring and/or allowing wash tub to drain indirectly. Stationary wash tub shall be directly connected to the drainage system. Wash tub with an adjustable tub height requires an approved alternate materials and methods application form to discharge indirectly. P0.2: Provided alternate materials and methods application form to use an accessible height drinking fountain with a bottle filler in lieu of the required high/low drinking fountain requires editing (see redlined alternate materials and methods application form) and fee collection prior to processing. P1.1: Provide dfu served by each section of the building drain (see clouds). Provided dfu do not add up to total shown on sheet P0.1. Note: Bathroom groups may be calculated per table 709.1. PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Plumbing | 1801037 |
Enumeration | Original | A | 2/9/2023 | BECKYA | BECKYA | | | Enumeration | 1800944 |
Submittal 4 | Original | / | 2/8/2023 | ANDREAL | ANDREAL | Submittal #4 | | Submittal 4 | 1800871 |
CO Springs Fire | Original | D | 1/17/2023 | CSFIRE | CSFIRE | WALK OK – See our “Virtual” Walk Through process here: https://coloradosprings.gov/sites/default/files/inline-images/walk-thru_memo.pdf
You are responsible for reviewing the DISAPPROVAL comments found on the CSFD website and responding to them in your resubmittal: https://web1.coloradosprings.gov/PreventionPlanReview/FPS_WebFPS.asp
PLEASE ALLOW UP TO AN HOUR FOR COMMENTS TO LOAD TO THE SERVERS – COMMENTS ARE AVAILABLE FOR ONLY 30 DAYS! | csfdit | CO Springs Fire | 1791624 |
CO Springs DRE | Original | D | 1/11/2023 | MALCURAN | MALCURAN | Disapproved. This project will require fees in lieu of land dedication for parks and schools (Please contact Candy Fontecchio for the exact fees (719-385-5191 or candy.fontecchio@ColoradoSprings.gov), After PLDO fees have been paid, please email matthew.alcuran@coloradosprings.gov for an update. | | CO Springs DRE | 1790214 |
Plumbing | Original | D | 1/11/2023 | TCRIPPEN | TCRIPPEN | Your pet wash tub will not meet code look into standing tub with ramp no moving parts and no rubber connections, PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Plumbing | 1789992 |
Zoning/Planning | Original | / | 1/9/2023 | MALCURAN | MALCURAN | In Current Review by MALCURAN | | Zoning/Planning | 1789398 |
Electrical | Original | D | 1/9/2023 | DANIELG | DANIELG | 1. Pending elevator approval
2. Pending construction approval of accessibility plan.
PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Electrical | 1789354 |
Electronic Plan | Original | / | 1/9/2023 | DANIELG | DANIELG | In Current Review by DANIELG | | Electronic Plan | 1789349 |
Mechanical | Original | D | 1/9/2023 | JUSTINC | JUSTINC | How is this being met when ducts is shown coming out of wall to a rated chase. Also this is a chase not shaft so how would the horizontal assembly be protected? There is no detail indicating a dropped ceiling in the bathrooms. This would indicate that the fan is penetrating the assembly. How will the fans be protected? This does not meet the #1 exception as it is in a chase no wall. How protecting horizontal assembly with through penetration?
Mechanical consult available if needed.
PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Mechanical | 1789248 |
CSU Water | Original | D | 1/9/2023 | CSUREVIEW | CSUREVIEW | Approved CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions.
Refer to 2023 Colorado Springs Utilities Water LESS details B4-1 through B4-8 and select the correct meter detail to include on the plumbing plans after approval of the Commercial Water Meter Sizing Form. Also refer to details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans. SSM | stefanm | CSU Water | 1789205 |
CSU Waste Water | Original | D | 1/9/2023 | CSUREVIEW | CSUREVIEW | CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. Refer to 2023 Colorado Springs Utilities Water LESS details B4-1 through B4-8 and select the correct meter detail to include on the plumbing plans after approval of the Commercial Water Meter Sizing Form. Also refer to details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans. SSM | stefanm | CSU Waste Water | 1789204 |
Elevators | Original | D | 1/9/2023 | ERIC | ERIC | Garaventa Vertical Platform Lift - Approval pending construction review.. PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Elevators | 1789135 |
Construction | Original | D | 1/9/2023 | SHELLEY | SHELLEY | Clarify garage separation on two floors when only garage level is required. Wheelchair lift must be in a shaft and cannot be open the landings on multiple floors. Clarify several areas where corridor rating appear non-compliant. Several areas need the uses of the spaces labeled. Match wall colors to RBD rated wall legend, or remove colors altogether. Several rated wall locations throughout plan are indicating non-rated construction. Some wall types are missing. Several doors incorrectly rated or cannot locate on floor plan. See plans for all comments. PLEASE NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF CORRECTIONS REQUIRED ON THE PLAN 1. FOR ELECTRONIC SUBMITTALS, A "PROGRESS SET" IS NOW AVAILABLE FOR REVIEW OF REQUIRED CORRECTIONS. 2. FOR ALL SUBMITTALS, A "REVIEW SET" WILL BE AVAILABLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. 3. PLANS CANNOT BE RE-SUBMITTED UNTIL EVERY DEPARTMENT HAS COMPLETED THIS CURRENT ROUND OF REVIEW. | | Construction | 1789131 |
Electronic Plan | Original | / | 1/9/2023 | SHELLEY | SHELLEY | In Current Review by SHELLEY | | Electronic Plan | 1788924 |
Enumeration | Original | A | 1/5/2023 | BECKYA | BECKYA | | | Enumeration | 1787995 |
Submittal 3 | Original | / | 1/5/2023 | ANDREAL | ANDREAL | Submittal #3 | | Submittal 3 | 1787902 |
CO Springs DRE | Original | D | 8/31/2022 | MALCURAN | MALCURAN | Disapproved. Waiting on CPC and CC approval....MDA... | | CO Springs DRE | 1736422 |
CO Springs Hazmat | Original | N | 8/10/2022 | CSFIRE | CSFIRE | | jt09ff | CO Springs Hazmat | 1726118 |
CO Springs Fire | Original | A | 8/10/2022 | CSFIRE | CSFIRE | You are responsible for reviewing the APPROVAL comments found on the CSFD website as they contain important inspection information: https://web1.coloradosprings.gov/PreventionPlanReview/FPS_WebFPS.asp PLEASE ALLOW UP TO AN HOUR FOR COMMENTS TO LOAD TO THE SERVERS – NOTE COMMENTS ARE AVAILABLE FOR 30 DAYS! ALL PLAN APPROVALS SUBJECT TO FINAL INSPECTION! | csfdit | CO Springs Fire | 1726116 |
Mechanical | Original | D | 7/27/2022 | JUSTINC | JUSTINC | How protecting?When ducts are indicated as penetrating a rated assembly a fire or fire/smoke damper is required. When intent is to use a code section and exception to not install a damper then a sheet note indicating code section and all exceptions used are to be provided on the plan. Tag at penetration accordingly. If dampers are existing indicate on plan.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1719209 |
Plumbing | Original | D | 7/26/2022 | SHANEN | SHANEN | CSU and construction review comments must be addressed. P0.1: Provide code section requiring and/or allowing wash tub to drain indirectly. P0.2: EWC model number is not for a drinking fountain. P1.1: Provide DFU served by each section of the building drain. Provide required CSU variance letter for the indoor sediment trap.Contact Robert Bowren at 719-668-1735 or fog@csu.org for more information. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 1718943 |
Elevators | Original | D | 7/25/2022 | ROBERTV | ROBERTV | Garaventa Vertical Platform Lift - Approval pending construction review comments related to IBC 712.1.9 (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Elevators | 1718466 |
Zoning/Planning | Original | / | 7/22/2022 | MALCURAN | MALCURAN | In Current Review by MALCURAN | | Zoning/Planning | 1717720 |
CSU Water | Original | D | 7/22/2022 | CSUREVIEW | CSUREVIEW | See previous comments. mjg | mgackle | CSU Water | 1717377 |
CSU Waste Water | Original | D | 7/22/2022 | CSUREVIEW | CSUREVIEW | See previous comments. mjg | mgackle | CSU Waste Water | 1717376 |
Construction | Original | D | 7/22/2022 | MICHAELA | MICHAELA | G100 - Verify the wheelchair lift meets the requirements of IBC sec. 712.1.9 and is not concealed in any building construction. G110 - The Accessibility Plan must be submitted as its own plan type in a separate folder. The plan must indicate compliance with Colorado Revised Statutes. Indicate that all units on the accessible level will be ANSI Type B. IECC - R-2 less than 4 stories must use the residential IECC form.Change of occupancy must comply with current codes. Fill in all assemblies with compliant values and indicate on the architectural plan where any changes need to occur. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1717375 |
Enumeration | Original | A | 7/21/2022 | BECKYA | BECKYA | | | Enumeration | 1716740 |
Electrical | Original | D | 7/21/2022 | DANIELG | DANIELG | 1. Pending elevator approval
2. Pending construction approval of accessibility plan.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1716731 |
Electronic Plan | Original | / | 7/21/2022 | DANIELG | DANIELG | In Current Review by DANIELG | | Electronic Plan | 1716721 |
Electronic Plan | Original | / | 7/21/2022 | BECKYA | BECKYA | In Current Review by BECKYA | | Electronic Plan | 1716604 |
Submittal 2 | Original | / | 7/21/2022 | KALLISTAJ | KALLISTAJ | Submittal #2 | | Submittal 2 | 1716543 |
CO Springs Hazmat | Original | D | 7/6/2022 | CSFIRE | CSFIRE | | Jacob.Watson | CO Springs Hazmat | 1709042 |
CO Springs Fire | Original | D | 7/6/2022 | CSFIRE | CSFIRE | Submitted By: Watson, Jacob Thomas You are responsible for reviewing the DISAPPROVAL comments found on the CSFD website and responding to them in your resubmittal: https://web1.coloradosprings.gov/PreventionPlanReview/FPS_WebFPS.asp
PLEASE ALLOW UP TO AN HOUR FOR COMMENTS TO LOAD TO THE SERVERS – COMMENTS ARE AVAILABLE FOR ONLY 30 DAYS! | csfdit | CO Springs Fire | 1709040 |
Electrical | Original | D | 6/27/2022 | SHELBY | SHELBY | 1. For units B-1.1 and B1 SCA exceedes AIC. 2. Remove equipment ground from service lateral. 3. Electrical approval is not possible without Elevator comments being addressed. 4. Provide accessibility plan (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Electrical | 1705069 |
Mechanical | Original | D | 6/27/2022 | JUSTINC | JUSTINC | See (M) sheets for comments from this review
Mechanical review incomplete No walk
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Mechanical | 1705021 |
Electronic Plan | Original | / | 6/27/2022 | JUSTINC | JUSTINC | In Current Review by JUSTINC | | Electronic Plan | 1704702 |
Plumbing | Original | D | 6/24/2022 | SHANEN | SHANEN | Construction review comments must be addressed. CSU comments must be addressed. Reference correct code section regarding solvent cementing (705.10.2). 4" building drain is undersized to serve 363 DFU per table 710.1(1). Provide/schedule required high/low drinking fountain. P1.1: Provide DFU served by each section of the building drain. Provide required CSU variance letter for the indoor sediment trap.Contact Robert Bowren at 719-668-1735 or fog@csu.org for more information. P1.2: Provide sizing for each section of the plumbing drainage system. P2.1, P3.1: 2"FD located under the clothes washer does not comply with section 802.4. (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Plumbing | 1703722 |
CO Springs DRE | Original | D | 6/24/2022 | MALCURAN | MALCURAN | Disapproved. Land Use Review application under current review. Project requires City Planning Commission prior to exterior remodel or interior remodel.....MDA.... | | CO Springs DRE | 1703592 |
Electronic Plan | Original | / | 6/23/2022 | SHELBY | SHELBY | In Current Review by SHELBY | | Electronic Plan | 1703532 |
Zoning/Planning | Original | / | 6/23/2022 | MALCURAN | MALCURAN | In Current Review by MALCURAN | | Zoning/Planning | 1703495 |
Zoning/Planning | Original | / | 6/23/2022 | JMALPICA | JMALPICA | In Current Review by JMALPICA | | Zoning/Planning | 1703494 |
CSU Water | Original | D | 6/23/2022 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set.
Reference Colorado Springs Utilities Water LESS meter detail with correct size after approval of Commercial Water Meter Sizing Form.
Utility service plan is not approved and attached to plan set so verification of service line entry location and sizes (including meter size) not performed yet.
Contact Utilities Development Services at 719-668-8259 with any questions. CJS | cjsavage | CSU Water | 1703462 |
CSU Waste Water | Original | D | 6/23/2022 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set.
Reference Colorado Springs Utilities Water LESS meter detail with correct size after approval of Commercial Water Meter Sizing Form.
Utility service plan is not approved and attached to plan set so verification of service line entry location and sizes (including meter size) not performed yet.
Contact Utilities Development Services at 719-668-8259 with any questions. CJS | cjsavage | CSU Waste Water | 1703461 |
Elevators | Original | D | 6/23/2022 | ERIC | ERIC | Please provide submittals for wheelchair lift. . (NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Elevators | 1702959 |
Construction | Original | D | 6/23/2022 | MICHAELA | MICHAELA | Change of occupancy from a B to an R-2 less than 4 stories requires the the IECC be complied with for the new occupancy. Provide a REScheck for the structure. G000 - Take the following page and split it into separate and compliant Life Safety Plan and an Accessibility Plan G100 - Verify the wheelchair lift meets the requirements of IBC sec. 712.1.9 and is not concealed in any building construction. Indicate separated use. The R-2 must be separated from the S-2. G200 - U341 is a wood wall. Provide a listing for metal framing, it is not interchangeable. Wall 1/C - Table 721 not 720. G201 - Correct detail 8. A100 - Per the demo plan there are more new walls than you are showing at the stair enclosures. Address the requirements of IBC sec. 1023.7 for the walls and openings adjacent to the Interior Exit Stairs. Typical both stairs. Stair enclosure must be 1-hr. Address any existing walls and provide an assembly. A110 - Address the 1-hr listing for existing walls at the stairs. Tag all walls with highlights. They are required to be rated. Indicate that glass in the corridor walls will be rated. A120 - Units must be separated from concealed spaces. Indicate correct wall type. Verify floor continues under concealed space. Storage must be separated from the corridor. Address the listing for any existing walls. A300 - Locate required clear floor space at toilet and shower. Provide an elevation showing required grab bar blocking for shower. Locate 30" work surface in kitchen. Indicate removable cabinetry as required. Locate shower controls. Show required turning radius in all rooms and spaces. Accessible route may only be reduced in 24" increments. Bedroom door is a 30" door. A310 - Indicate if the units are option a or b.Locate required clear floor space at toilet and tub. Accessible route may only be reduced in 24" increments. The bedroom doors are 30" door.
(NOTE - THE DISAPPROVAL COMMENTS ABOVE MAY NOT REPRESENT THE COMPLETE LIST OF COMMENTS. FOR ALL COMMENTS, THE DESIGNER SHALL CONDUCT A FULL EXAMINATION OF THE DISAPPROVED SET, WHICH WILL BE ACCESSIBLE UPON COMPLETION OF ALL DEPARTMENT REVIEWS. AFTER THE DESIGNER’S EXAMINATION, INDIVIDUAL REVIEWERS ARE AVAILABLE FOR DISCUSSION ON COMMENTS VIA PHONE, EMAIL, OR IN PERSON.) | | Construction | 1702927 |
Electronic Plan | Original | / | 6/22/2022 | MICHAELA | MICHAELA | In Current Review by MICHAELA | | Electronic Plan | 1702175 |
Enumeration | Original | A | 6/14/2022 | BRENT | BRENT | | | Enumeration | 1697902 |
Electronic Plan | Original | / | 6/14/2022 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 1697894 |
Floodplain | Original | N | 6/10/2022 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6416117029) | | Floodplain | 1696611 |