CO Springs DRE | Original | A | 9/19/2022 | APAQUETTE | APAQUETTE | Approved per DEPN-22-0059 (see full review) | | CO Springs DRE | 1743002 |
Zoning/Planning | Original | / | 9/19/2022 | APAQUETTE | APAQUETTE | In Current Review by APAQUETTE | | Zoning/Planning | 1742977 |
Submittal 3 | Original | / | 9/16/2022 | BPHILLIPS | BPHILLIPS | Submittal #3 | | Submittal 3 | 1742393 |
CO Springs Fire | Original | A | 8/18/2022 | CSFIRE | CSFIRE | You are responsible for reviewing the comments found on the CSFD website for any corrections to be made and/or inspection information: https://web1.coloradosprings.gov/PreventionPlanReview/FPS_WebFPS.asp NOTE: Plan review comments may take up to an hour to be uploaded | rpeterson | CO Springs Fire | 1730334 |
CO Springs DRE | Original | D | 8/18/2022 | APAQUETTE | APAQUETTE | No record of a minor modification has been found at this parcel. To start the minor modification process, please submit a pre-application meeting request at https://coloradosprings.gov/planning-and-development. Please contact me at 719-385-5080 or adam.paquette@coloradosprings.gov with any questions. (see full review) | | CO Springs DRE | 1730149 |
Zoning/Planning | Original | / | 8/18/2022 | APAQUETTE | APAQUETTE | In Current Review by APAQUETTE | | Zoning/Planning | 1730122 |
Submittal 2 | Original | / | 8/17/2022 | KALLISTAJ | KALLISTAJ | Submittal #2 | | Submittal 2 | 1729467 |
Electrical | Original | A | 6/29/2022 | SHELBY | SHELBY | | | Electrical | 1706564 |
Electronic Plan | Original | / | 6/29/2022 | SHELBY | SHELBY | In Current Review by SHELBY | | Electronic Plan | 1706563 |
CO Springs DRE | Original | D | 6/29/2022 | APAQUETTE | APAQUETTE | Please submit a pre-application meeting request at https://coloradosprings.gov/planning-and-development/webform/pre-application-meeting-request (see full review) | | CO Springs DRE | 1706335 |
Plumbing | Original | N | 6/27/2022 | SHANEN | SHANEN | No plumbing scope of work indicated. | | Plumbing | 1705041 |
Zoning/Planning | Original | / | 6/27/2022 | APAQUETTE | APAQUETTE | In Current Review by APAQUETTE | | Zoning/Planning | 1704998 |
CO Springs Hazmat | Original | N | 6/27/2022 | CSFIRE | CSFIRE | | dwithee | CO Springs Hazmat | 1704990 |
CO Springs Fire | Original | D | 6/27/2022 | CSFIRE | CSFIRE | 2015 IFC 503.1, 506.1.1, D103.5
Gates securing the fire apparatus access roads shall comply with all of the following criteria:
1. Where a single gate is provided, the gate width shall be not less than 16 feet 2. Gates shall be of the swinging or sliding type unless otherwise specifically approved. 3. Construction of gates shall be of materials that allow manual operation by one person. 4. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 5. Methods of locking shall be submitted for approval by the fire code official. 6. Electric gate operators, where provided, shall be listed in accordance with UL 325. 7. Gates intended for automatic operation shall be designed, constructed and installed to comply with the requirements of ASTM F 2200. | dwithee | CO Springs Fire | 1704989 |
Mechanical | Original | N | 6/27/2022 | DALEH | DALEH | | | Mechanical | 1704957 |
Construction | Original | N | 6/27/2022 | MICHAELA | MICHAELA | | | Construction | 1704905 |
Enumeration | Original | N | 6/23/2022 | AMY | AMY | The service to the security gate is being routed from the garage therefore the address to this plan should be the garage address. 2262 Briargate Pkwy. Addressing to the entire plan has been changed for you. If any of the sheets get changed out, edit to correct the address. | | Enumeration | 1702886 |
Electronic Plan | Original | / | 6/23/2022 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 1702848 |
Floodplain | Original | N | 6/20/2022 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6233202006) | | Floodplain | 1700708 |