Electrical | Original | A | 8/8/2024 | DANIELG | DANIELG | | | Electrical | 2043962 |
CSU Water | Original | D | 8/2/2024 | CSUREVIEW | CSUREVIEW | Comments not addressed. It appears that there is an updated service plan attached but it is not approved. An approved revised Utility Service Plan is required to be attached.
Provide EITHER detail B4-5 OR B4-8, not both on the plumbing plans. SSM | stefanm | CSU Water | 2041534 |
Plumbing | Original | D | 8/2/2024 | SHANEN | SHANEN | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Plumbing | 2041443 |
Submittal 4 | Original | / | 8/2/2024 | QUINTONW | QUINTONW | Submittal #4 | | Submittal 4 | 2041406 |
CO Springs Hazmat | Original | N | 6/12/2024 | CSFIRE | CSFIRE | Not a Class 3 Oxidizer - Below Permit Qyuantities N/ASubmitted By: Stanwood, Mark Antone,Submitted By: Stanwood, Mark Antone | mark.stanwood@colora | CO Springs Hazmat | 2018836 |
CO Springs DRE | Original | A | 6/11/2024 | MOBRIEN | MOBRIEN | Plans consistent with approved Land Use Review entitlement. (see full review) | | CO Springs DRE | 2018407 |
Zoning/Planning | Original | / | 6/10/2024 | MOBRIEN | MOBRIEN | In Current Review by MOBRIEN | | Zoning/Planning | 2017203 |
Mechanical | Original | A | 6/10/2024 | TREVORH | TREVORH | Approved; | | Mechanical | 2017169 |
Stormwater | Original | A | 6/7/2024 | JLANDON | JLANDON | no spot for storm water, stamped next to health department | | Stormwater | 2016993 |
Plumbing | Original | D | 6/7/2024 | SHANEN | SHANEN | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Plumbing | 2016877 |
Electrical | Original | D | 6/7/2024 | DANIELG | DANIELG | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Electrical | 2016830 |
CSU Waste Water | Original | A | 6/7/2024 | CSUREVIEW | CSUREVIEW | Comments addressed. SSM | stefanm | CSU Waste Water | 2016776 |
CSU Water | Original | D | 6/7/2024 | CSUREVIEW | CSUREVIEW | The approved Utility Servivce Plan does not match the plumbing plan. The plumbing plan proposes a 1.5" service line, but the USP proposes a 3/4" copper service line.
The meter and backflow loop details provided on the plumbing plans are for HDPE service, but the approved USP proposes type K copper service. Coordinate with civil engineer and plumbing engineer to fix. SSM | stefanm | CSU Water | 2016773 |
Submittal 3 | Original | / | 6/7/2024 | QUINTONW | QUINTONW | Submittal #3 | | Submittal 3 | 2016763 |
CO Springs Hazmat | Original | D | 12/19/2023 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. EXCEEDS MAQ for Calcium Hypoclorite (see full review) | mark.stanwood@colora | CO Springs Hazmat | 1942405 |
CO Springs Fire | Original | A | 12/18/2023 | CSFIRE | CSFIRE | We are pleased to inform you this plan is approved. You are responsible for reviewing the comments through your ACA account. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account.
ALL PLAN APPROVALS SUBJECT TO FINAL INSPECTION!
HAZMAT REVIEWERS HAVE BEEN NOTIFIED OF PENDING REVIEW | dwithee | CO Springs Fire | 1942101 |
Stormwater | Original | D | 12/13/2023 | EWANG | EWANG | Upload approved Development Plan showing retaining wall locations and top of wall/bottom of wall elevations. They should match GEC Plan. | | Stormwater | 1939970 |
CO Springs DRE | Original | D | 12/12/2023 | MOBRIEN | MOBRIEN | Please upload entire development plan with approval stamp - not all sheets under "Civil Plans" included stamp. Preferably, complete approved development plan would be uploaded under "Development Plan," not "Civil Plan." (see full review) | | CO Springs DRE | 1939217 |
CSU Water | Original | D | 12/11/2023 | CSUREVIEW | CSUREVIEW | See previous comments.
Refer to 2023 Colorado Springs Utilities WaterLESS details B4-1 through B4-8 and select the correct meter detail to include on the plumbing plans after approval of the Commercial Water Meter Sizing Form. Also refer to details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans. CJS | cjsavage | CSU Water | 1938630 |
CSU Waste Water | Original | D | 12/11/2023 | CSUREVIEW | CSUREVIEW | See previous comments. CJS | cjsavage | CSU Waste Water | 1938629 |
Mechanical | Original | D | 12/11/2023 | JUSTINC | JUSTINC | Provide refrigeration calculation per 2015 IMC 1103.1 Verify if within allowable limits per table on plan. If over the allowable limits indicate how protecting on plan. 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Mechanical | 1938525 |
Health Dept. | Original | N | 12/9/2023 | HEALTHDEPT | HEALTHDEPT | Construction activity permit PT1408 is valid from 12/1/23 - 6/1/24. To continue any earthmoving operations after 6/1/24, please reapply for a new permit online at https://www.elpasocountyhealth.org/service/air-quality/construction-activity-application . For questions, contact Environmental Health at 719-578-3199 option 3. AB | abrannon | Health Dept. | 1938286 |
Electrical | Original | D | 12/8/2023 | DANIELG | DANIELG | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Electrical | 1938094 |
Electronic Plan | Original | / | 12/8/2023 | DANIELG | DANIELG | In Current Review by DANIELG | | Electronic Plan | 1938084 |
Zoning/Planning | Original | / | 12/8/2023 | MOBRIEN | MOBRIEN | In Current Review by MOBRIEN | | Zoning/Planning | 1938026 |
Construction | Original | A | 12/8/2023 | CGIECK | CGIECK | OK | | Construction | 1938025 |
Plumbing | Original | D | 11/30/2023 | SHANEN | SHANEN | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Plumbing | 1934172 |
Enumeration | Original | A | 11/29/2023 | BECKYA | BECKYA | | | Enumeration | 1933366 |
Submittal 2 | Original | / | 11/28/2023 | BRIANNAM | BRIANNAM | Submittal #2 | | Submittal 2 | 1933170 |
CSU Contract Admin. | Original | A | 11/16/2023 | CSUAPPSPRM | CSUAPPSPRM | Commercial water meter sizing form approved and applicable development charges and fees paid. AMS | ASweet | CSU Contract Admin. | 1929279 |
CSU Contract Admin. | Original | / | 11/16/2023 | CSUAPPSPRM | CSUAPPSPRM | | ASweet | CSU Contract Admin. | 1929277 |
CO Springs DRE | Original | D | 8/7/2023 | ESHAFER | ESHAFER | Approved Development Plan (with Land Use Review approval stamp present) must be uploaded. Current upload does not show approval stamp. (see full review) | | CO Springs DRE | 1881638 |
CO Springs Hazmat | Original | D | 8/4/2023 | CSFIRE | CSFIRE | pending receipt of completed documents required by fire construction review | dwithee | CO Springs Hazmat | 1880821 |
CO Springs Fire | Original | D | 8/4/2023 | CSFIRE | CSFIRE | We regret to inform you, this plan is disapproved. You are responsible for reviewing the DISAPPROVAL comments found on the CSFD website and responding to them in your resubmittal: https://web1.coloradosprings.gov/PreventionPlanReview/FPS_WebFPS.asp PLEASE ALLOW UP TO AN HOUR FOR COMMENTS TO LOAD TO THE SERVERS – COMMENTS ARE AVAILABLE FOR ONLY 30 DAYS! (see full review) | csfdit | CO Springs Fire | 1880819 |
CO Springs Fire | Original | D | 8/4/2023 | CSFIRE | CSFIRE | We regret to inform you, this plan is disapproved. You are responsible for reviewing the DISAPPROVAL comments found on the CSFD website and responding to them in your resubmittal: https://web1.coloradosprings.gov/PreventionPlanReview/FPS_WebFPS.asp PLEASE ALLOW UP TO AN HOUR FOR COMMENTS TO LOAD TO THE SERVERS – COMMENTS ARE AVAILABLE FOR ONLY 30 DAYS! (see full review) | csfdit | CO Springs Fire | 1880817 |
Mechanical | Original | D | 8/4/2023 | JUSTINC | JUSTINC | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Mechanical | 1880454 |
CSU Contract Admin. | Original | D | 8/4/2023 | CSUAPPSPRM | CSUAPPSPRM | Requires approved Commercial Water Meter Sizing Form (CWMSF) and payment of applicable utility charges and fees. Please contact Customer Contract Administration at 719-668-8111 to discuss charges/fees and request an estimate. CWMSF available online at:
https://www.csu.org/CSUDocuments/watermetersizingforminteractive.pdf
CZ | c.zani | CSU Contract Admin. | 1880343 |
City Engr | Original | A | 8/1/2023 | PMORRIS | PMORRIS | | | City Engr | 1878522 |
Zoning/Planning | Original | / | 8/1/2023 | ESHAFER | ESHAFER | In Current Review by ESHAFER | | Zoning/Planning | 1878340 |
Plumbing | Original | D | 8/1/2023 | SHANEN | SHANEN | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Plumbing | 1878309 |
Electrical | Original | D | 7/31/2023 | DANIELG | DANIELG | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Electrical | 1878187 |
Electronic Plan | Original | / | 7/31/2023 | DANIELG | DANIELG | In Current Review by DANIELG | | Electronic Plan | 1878181 |
Elevators | Original | N | 7/31/2023 | ROBERTV | ROBERTV | No Conveyances | | Elevators | 1878133 |
CSU Water | Original | D | 7/31/2023 | CSUREVIEW | CSUREVIEW | Size and/or location of incoming water service line does not match approved utility service plan. Coordinate between plumbing and civil design to ensure they match.
Refer to 2023 Colorado Springs Utilities WaterLESS details B4-1 through B4-8 and select the correct meter detail to include on the plumbing plans after approval of the Commercial Water Meter Sizing Form. Also refer to details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans.
SSM | stefanm | CSU Water | 1877919 |
CSU Waste Water | Original | D | 7/31/2023 | CSUREVIEW | CSUREVIEW | The location of the wastewater service line on the plumbing drawings does not match approved Utility Service Plan. Coordinate the plumbing engineer and civil engineer to ensure that your service line locations match in material, size, and location between the two plans. SSM | stefanm | CSU Waste Water | 1877918 |
Gas/Elec. Utils | Original | A | 7/31/2023 | CSUREVIEW | CSUREVIEW | CSU Field Engineer to determine final gas/electric meter, transformer and service line locations. Contact Field Engineering at 719-668-4985 (Gas) or 719-668-5564 (Electric) with any questions. SSM | stefanm | Gas/Elec. Utils | 1877917 |
Health Dept. | Original | D | 7/31/2023 | HEALTHDEPT | HEALTHDEPT | Construction activity permit required for projects earthmoving > 1 acre. If the entire project is > 1 acre earthmoving, regardless of being submitted in phases and/or separate building permits, a construction activity permit will be required. Information and application may be accessed online at: https://www.elpasocountyhealth.org/service/air-quality/construction-activity-application. Please email application and all required documents to healthinfo@elpasoco.com. For questions, contact Environmental Health at 719-578-3199 option 3. AF | Amanda Furno | Health Dept. | 1877913 |
Construction | Original | D | 7/31/2023 | CGIECK | CGIECK | Please review progress set. 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Construction | 1877891 |
Electronic Plan | Original | / | 7/31/2023 | CGIECK | CGIECK | In Current Review by CGIECK | | Electronic Plan | 1877558 |
Enumeration | Original | A | 7/6/2023 | BECKYA | BECKYA | | | Enumeration | 1866927 |
Electronic Plan | Original | / | 7/6/2023 | BECKYA | BECKYA | In Current Review by BECKYA | | Electronic Plan | 1866896 |
Floodplain | Original | N | 7/3/2023 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6436324358) | | Floodplain | 1866092 |