CO Springs DRE | Original | A | 7/10/2024 | MOBRIEN | MOBRIEN | Approved for west clubhouse. (see full review) | | CO Springs DRE | 2030781 |
Electrical | Original | A | 7/9/2024 | RICHG | RICHG | | | Electrical | 2029812 |
Energy | Original | D | 7/9/2024 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2029813 |
City Engr | Original | D | 7/9/2024 | JDAGNILLO | JDAGNILLO | Include a copy of both the Stormwater Enterprise approved Grading & Erosion Control Plan and Permanent Control Measure (Permanent Water Quality Facility) Plan in the electronic building permit set. (#STM-REV23-0521 & 0742) | | City Engr | 2029687 |
CSU Water | Original | D | 7/8/2024 | CSUREVIEW | CSUREVIEW | See previous comments. CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions.Refer to 2023 Colorado Springs Utilities WaterLESS details B4-1 through B4-8 and select the correct meter detail to include on the plumbing plans after approval of the Commercial Water Meter Sizing Form. Also refer to details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans.MDA | malcuran | CSU Water | 2029299 |
CSU Waste Water | Original | D | 7/8/2024 | CSUREVIEW | CSUREVIEW | See previous comments. CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. Update plumbling plan.MDA | malcuran | CSU Waste Water | 2029297 |
Gas/Elec. Utils | Original | D | 7/8/2024 | CSUREVIEW | CSUREVIEW | CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions.MDA | malcuran | Gas/Elec. Utils | 2029295 |
Plumbing | Original | D | 7/8/2024 | SHANEN | SHANEN | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Plumbing | 2029174 |
Zoning/Planning | Original | / | 7/8/2024 | MOBRIEN | MOBRIEN | In Current Review by MOBRIEN | | Zoning/Planning | 2029166 |
CSU Contract Admin. | Original | D | 7/8/2024 | CSUAPPSPRM | CSUAPPSPRM | Same comment as noted 05/03/2024 - Requires approved Commercial Water Meter Sizing Form (CWMSF) and payment of applicable utility charges and fees. Please contact Customer Contract Administration at 719-668-8111 for additional information on charges/fees and to request an estimate. CWMSF available online at:
https://www.csu.org/CSUDocuments/watermetersizingforminteractive.pdf
AMS | ASweet | CSU Contract Admin. | 2029165 |
Mechanical | Original | A | 7/8/2024 | DALEH | DALEH | | | Mechanical | 2029091 |
Construction | Original | A | 7/8/2024 | CGIECK | CGIECK | Approved | | Construction | 2029071 |
Electronic Plan | Original | / | 7/8/2024 | CGIECK | CGIECK | In Current Review by CGIECK | | Electronic Plan | 2028950 |
Enumeration | Original | A | 7/3/2024 | AMY | AMY | | | Enumeration | 2028247 |
Electronic Plan | Original | / | 7/3/2024 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 2028243 |
| Original | / | 7/3/2024 | SYSTEM | SYSTEM | Resubmittal Processing Fee(s) Paid | | | 2028236 |
| Original | / | 7/3/2024 | SYSTEM | SYSTEM | Resubmittal Processing Fee Due | | | 2028118 |
Submittal 3 | Original | / | 7/3/2024 | BRIANNAM | BRIANNAM | Submittal #3 | | Submittal 3 | 2028117 |
CO Springs Fire | Original | A | 5/16/2024 | CSFIRE | CSFIRE | You are responsible for reviewing the comments through your ACA account. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. ALL PLAN APPROVALS SUBJECT TO FINAL INSPECTION! | rpeterson | CO Springs Fire | 2004887 |
Energy | Original | D | 5/7/2024 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 1999507 |
Mechanical | Original | D | 5/7/2024 | DALEH | DALEH | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Mechanical | 1999506 |
CO Springs DRE | Original | D | 5/6/2024 | SSADLER | SSADLER | The Development Plan that was submitted is not the approved set. The approved Development Plan will be stamped by the city. (see full review) | | CO Springs DRE | 1999040 |
Electrical | Original | D | 5/6/2024 | RICHG | RICHG | Electrical comm check must be stamped.
Comply with C405.11 IECC. (i.e. conference rooms, break/kitchenette offices etc...)
Pool panel is rated at 22k and available is 25K+. Panel is under rated for available fault current.
Panel schedule should match floor plans.
Dishwasher circuit should be gfci protected. 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Electrical | 1998969 |
Zoning/Planning | Original | / | 5/3/2024 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 1998589 |
CSU Contract Admin. | Original | D | 5/3/2024 | CSUAPPSPRM | CSUAPPSPRM | Requires Commercial Water Meter Sizing Form (https://www.csu.org/CSUDocuments/commercialwatermetersizingform.pdf) and payment of applicable development charges/fees. Contact Customer Contract Administration at 719-668-8111 for more information. BS | bschifferstein | CSU Contract Admin. | 1998546 |
Plumbing | Original | D | 5/3/2024 | SHANEN | SHANEN | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Plumbing | 1998481 |
CSU Water | Original | D | 5/3/2024 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions.
Refer to 2023 Colorado Springs Utilities WaterLESS details B4-1 through B4-8 and select the correct meter detail to include on the plumbing plans after approval of the Commercial Water Meter Sizing Form. Also refer to details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans. mjg | mgackle | CSU Water | 1998400 |
City Engr | Original | D | 5/3/2024 | JDAGNILLO | JDAGNILLO | See previous comment - Include a copy of the approved Development Plan and a copy of both the Stormwater Enterprise approved Grading & Erosion Control Plan and Permanent Control Measure (Permanent Water Quality Facility) Plan in the electronic building permit set. (#STM-REV23-0521 & 0742) | | City Engr | 1998399 |
CSU Waste Water | Original | D | 5/3/2024 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. mjg | mgackle | CSU Waste Water | 1998398 |
Gas/Elec. Utils | Original | D | 5/3/2024 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. mjg | mgackle | Gas/Elec. Utils | 1998397 |
Construction | Original | D | 5/3/2024 | CGIECK | CGIECK | PLEASE REVIEW PROGRESS SET. 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Construction | 1998362 |
Electronic Plan | Original | / | 5/2/2024 | CGIECK | CGIECK | In Current Review by CGIECK | | Electronic Plan | 1998137 |
Enumeration | Original | A | 5/2/2024 | AMY | AMY | | | Enumeration | 1998039 |
Submittal 2 | Original | / | 5/1/2024 | BRIANNAM | BRIANNAM | Submittal #2 | | Submittal 2 | 1997569 |
CO Springs Fire | Original | D | 11/30/2023 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | rpeterson | CO Springs Fire | 1933919 |
CO Springs Hazmat | Original | N | 11/30/2023 | CSFIRE | CSFIRE | | rpeterson | CO Springs Hazmat | 1933918 |
Energy | Original | D | 11/20/2023 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 1930514 |
Mechanical | Original | D | 11/20/2023 | DALEH | DALEH | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Mechanical | 1930513 |
Electrical | Original | D | 11/20/2023 | RICHG | RICHG | Provide SCA and SCCR for all refrigeration equipment.
Where applicable, Daylight Zones must be shown on the plans per C405.2.4.2 through C405.2.4.4
Controlled receptacles must be shown on the plan per C405.11 and the symbol used to mark these receptacles must be as shown in article 406.3(E) of the adopted National Electrical Code (NEC).
Provide a note on the plans indicating that the Electrical design has a maximum volt drop of 5% per C405.10.
The following general note must be included on the electrical plans: “A Final Commissioning Report shall be delivered to the building owner per section C408.2.5 of the 2021 IECC.”
Electrical Com check must be stamped.
1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Electrical | 1930446 |
Health Dept. | Original | N | 11/17/2023 | HEALTHDEPT | HEALTHDEPT | Colorado Department of Health and Environment Air Pollutant Emission Notice (APEN) may be required for projects earthmoving > 25 acres. Contact CDPHE for more information or visit their website at https://cdphe.colorado.gov/apens-and-air-permits/do-you-need-an-apen-or-air-permit.TG | tguerrero | Health Dept. | 1930277 |
Electronic Plan | Original | / | 11/17/2023 | RICHG | RICHG | In Current Review by RICHG | | Electronic Plan | 1930233 |
Plumbing | Original | D | 11/17/2023 | SHANEN | SHANEN | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Plumbing | 1929916 |
Elevators | Original | N | 11/17/2023 | ERIC | ERIC | No conveyance | | Elevators | 1929877 |
CO Springs DRE | Original | D | 11/17/2023 | MOBRIEN | MOBRIEN | Please upload approved development plan stamped by Land Use Review. (see full review) | | CO Springs DRE | 1929841 |
Zoning/Planning | Original | / | 11/17/2023 | MOBRIEN | MOBRIEN | In Current Review by MOBRIEN | | Zoning/Planning | 1929840 |
CSU Water | Original | D | 11/17/2023 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions.
Refer to 2023 Colorado Springs Utilities WaterLESS details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans. SSM | stefanm | CSU Water | 1929834 |
CSU Waste Water | Original | D | 11/17/2023 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. SSM | stefanm | CSU Waste Water | 1929833 |
Gas/Elec. Utils | Original | D | 11/17/2023 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. SSM | stefanm | Gas/Elec. Utils | 1929832 |
City Engr | Original | D | 11/17/2023 | PMORRIS | PMORRIS | Upload a copy of the Stormwater Enterprise approved Grading & Erosion Control Plan (GECP) and the Permanent Control Measure (water quality facility) construction plan into the building permit. Upload a copy of the Approved Development Plan into the building permit. | | City Engr | 1929795 |
CSU Contract Admin. | Original | D | 11/16/2023 | CSUAPPSPRM | CSUAPPSPRM | Requires approved Commercial Water Meter Sizing Form (CWMSF) and payment of applicable utility charges and fees. Please contact Customer Contract Administration at 719-668-8111 to discuss charges/fees and request an estimate. CWMSF available online at:
https://www.csu.org/CSUDocuments/watermetersizingforminteractive.pdf
CZ | c.zani | CSU Contract Admin. | 1929788 |
Construction | Original | D | 11/16/2023 | CGIECK | CGIECK | PLEASE REVIEW PROGRESS SET 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Construction | 1929773 |
Electronic Plan | Original | / | 11/14/2023 | CGIECK | CGIECK | In Current Review by CGIECK | | Electronic Plan | 1928458 |
Floodplain | Original | N | 11/14/2023 | AMY | AMY | | | Floodplain | 1928313 |
Enumeration | Original | D | 11/14/2023 | AMY | AMY | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Enumeration | 1928312 |
Electronic Plan | Original | / | 11/14/2023 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 1928295 |
Energy | Original | / | 10/25/2023 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 1918468 |