Electrical | Splice 08/06/24 | A | 8/10/2024 | DANIELG | DANIELG | | | Electrical | 2044912 |
Construction | Splice 08/06/24 | A | 8/6/2024 | DANM | DANM | Revised array layout | | Construction | 2042727 |
Electronic Plan | Splice 08/06/24 | / | 8/6/2024 | DANM | DANM | In Current Review by DANM | | Electronic Plan | 2042719 |
Electrical | Original | A | 6/21/2024 | DANIELG | DANIELG | | | Electrical | 2023053 |
Electronic Plan | Original | / | 6/21/2024 | DANIELG | DANIELG | In Current Review by DANIELG | | Electronic Plan | 2023014 |
Construction | Original | A | 6/18/2024 | ANDREAL | ANDREAL | Approved. No inspection required. Ballest System. | | Construction | 2020817 |
Electronic Plan | Original | / | 6/18/2024 | ANDREAL | ANDREAL | In Current Review by ANDREAL | | Electronic Plan | 2020814 |
Enumeration | Original | A | 6/17/2024 | BECKYA | BECKYA | | | Enumeration | 2020763 |
| Original | / | 6/17/2024 | SYSTEM | SYSTEM | Resubmittal Processing Fee(s) Paid | | | 2020712 |
| Original | / | 6/17/2024 | SYSTEM | SYSTEM | Resubmittal Processing Fee Due | | | 2020704 |
Submittal 3 | Original | / | 6/17/2024 | SIERRAC | SIERRAC | Submittal #3 | | Submittal 3 | 2020703 |
Electrical | Original | D | 6/14/2024 | SHELBY | SHELBY | Maximum string wattage has been exceeded in this design. 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Electrical | 2019932 |
CO Springs Hazmat | Original | A | 6/13/2024 | CSFIRE | CSFIRE | Re-Review Approved MUS (see full review) | mark.stanwood@colora | CO Springs Hazmat | 2019300 |
CO Springs Hazmat | Original | D | 6/12/2024 | CSFIRE | CSFIRE | Pervios Comments Not Addrtessed, Still require 6 FT Perimiter. You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. DFM-C-SV-24-00006 (see full review) | mark.stanwood@colora | CO Springs Hazmat | 2019065 |
Electronic Plan | Original | / | 6/12/2024 | SHELBY | SHELBY | In Current Review by SHELBY | | Electronic Plan | 2019036 |
CO Springs DRE | Original | A | 6/7/2024 | SSADLER | SSADLER | Flush mount roof solar panels and/or PV solar panels do not exceed maximuml height requirements (see full review) | | CO Springs DRE | 2016888 |
Zoning/Planning | Original | / | 6/7/2024 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2016707 |
Construction | Original | D | 6/7/2024 | ANDREAL | ANDREAL | Approval pending Enumerations comment to fill out the Code Study. 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Construction | 2016496 |
Electronic Plan | Original | / | 6/7/2024 | ANDREAL | ANDREAL | In Current Review by ANDREAL | | Electronic Plan | 2016491 |
Enumeration | Original | D | 6/6/2024 | BECKYA | BECKYA | See Code Study Form for disapproval comments. 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Enumeration | 2016408 |
Submittal 2 | Original | / | 6/3/2024 | BRIANNAM | BRIANNAM | Submittal #2 | | Submittal 2 | 2014317 |
CO Springs Hazmat | Original | D | 5/23/2024 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. DFM-C-SV-24-00006 (see full review) | mark.stanwood@colora | CO Springs Hazmat | 2008278 |
CO Springs Fire | Original | N | 5/22/2024 | CSFIRE | CSFIRE | | chiptaylor | CO Springs Fire | 2007463 |
Electrical | Original | D | 5/11/2024 | SHELBY | SHELBY | 1. Transformer secondary circuit conductor installation violates 690.9(A)(2) NEC. 2. Optimizer specification does not include inverter SE100K in the system design table. 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Electrical | 2002242 |
Electronic Plan | Original | / | 5/7/2024 | SHELBY | SHELBY | In Current Review by SHELBY | | Electronic Plan | 1999847 |
CO Springs DRE | Original | D | 5/6/2024 | SSADLER | SSADLER | Correct the height of the building on the code study form. It shows 85' the development plan shows 50'. On the site plan state whether or not these panels are flush mounted or not. (see full review) | | CO Springs DRE | 1999194 |
Zoning/Planning | Original | / | 5/6/2024 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 1998850 |
Construction | Original | A | 5/6/2024 | ANDREAL | ANDREAL | Approved. No Inspection required. Ballest System. | | Construction | 1998795 |
Electronic Plan | Original | / | 5/6/2024 | ANDREAL | ANDREAL | In Current Review by ANDREAL | | Electronic Plan | 1998751 |
Enumeration | Original | A | 4/30/2024 | AMY | AMY | PV SOLAR address 2847 Zeppelin Road | | Enumeration | 1996435 |
Electronic Plan | Original | / | 4/30/2024 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 1996406 |
Energy | Original | N | 4/29/2024 | SYSTEM | SYSTEM | Energy Department review not required under 2023 PPRBC when IECC is N/A | | Energy | 1995972 |
Floodplain | Original | N | 4/29/2024 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6436105001) | | Floodplain | 1995971 |