CO Springs Hazmat | Original | N | 12/5/2024 | CSFIRE | CSFIRE | No inspection | michael.davis1@color | CO Springs Hazmat | 2095188 |
CO Springs Fire | Original | N | 12/5/2024 | CSFIRE | CSFIRE | No Fire Inspection | michael.davis1@color | CO Springs Fire | 2095186 |
CSU Water | Original | N | 11/25/2024 | CSUREVIEW | CSUREVIEW | No new water service outside of building. Backflow preventer compliant/conforming.MDA | malcuran | CSU Water | 2089381 |
CSU Waste Water | Original | N | 11/25/2024 | CSUREVIEW | CSUREVIEW | No new wastewater service outside of building. MDA | malcuran | CSU Waste Water | 2089377 |
CO Springs DRE | Original | A | 11/25/2024 | SSADLER | SSADLER | Previous approval comments still apply | | CO Springs DRE | 2089358 |
Energy | Original | D | 11/22/2024 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2089132 |
Mechanical | Original | D | 11/22/2024 | TREVORH | TREVORH | Disapproved; Need Mechanical plans. Need construction review comments addressed. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2089131 |
Electrical | Original | D | 11/22/2024 | RICHG | RICHG | Review stopped. Pending construction.
See construction comments. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2089127 |
Plumbing | Original | D | 11/22/2024 | SHANEN | SHANEN | Construction review comments must be addressed. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2089117 |
Construction | Original | D | 11/22/2024 | DANM | DANM | Per RBD records it appears this building was converted to an MMJ facility without any permits per complaint in 2010. Current submittal seems to include construction interior remodel. Provide architectural set of drawings with all code information indicating current use. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2089108 |
Electronic Plan | Original | / | 11/22/2024 | RICHG | RICHG | In Current Review by RICHG | | Electronic Plan | 2089017 |
Mechanical | Original | N | 11/4/2024 | TREVORH | TREVORH | Not Applicable; | | Mechanical | 2081192 |
CO Springs Fire | Original | N | 11/4/2024 | CSFIRE | CSFIRE | NO INSPECTION | michael.davis1@color | CO Springs Fire | 2081109 |
CO Springs Hazmat | Original | N | 11/4/2024 | CSFIRE | CSFIRE | NO INSPECTION | michael.davis1@color | CO Springs Hazmat | 2081106 |
Plumbing | Original | N | 11/4/2024 | SHANEN | SHANEN | | | Plumbing | 2080831 |
CO Springs DRE | Original | A | 11/1/2024 | SSADLER | SSADLER | Interior remodel only. No change in footprint, No change in parking. No change in occupancy. | | CO Springs DRE | 2080783 |
Zoning/Planning | Original | / | 11/1/2024 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2080715 |
CSU Waste Water | Original | N | 11/1/2024 | CSUREVIEW | CSUREVIEW | No new wastewater service outside of building. SSM | stefanm | CSU Waste Water | 2080699 |
CSU Water | Original | D | 11/1/2024 | CSUREVIEW | CSUREVIEW | Requires submittal of a Backflow Assembly Plan Review Form to determine if the service backflow prevention meets Standards. Form can be found at: https://www.csu.org/Documents/DomesticAssembly.pdf?csf=1&e=KLQNrS
***Form must be submitted to crossconnection@csu.org. Contact Utilities Development Services at 719-668-8259 with any questions.*** SSM | stefanm | CSU Water | 2080693 |
Enumeration | Original | N | 11/1/2024 | AMY | AMY | The legal description box on the Code Study form is not the owner of the property. This information was corrected for you, but can be found on the El Paso County Assessor's database. In the future please access this site. | | Enumeration | 2080672 |
Energy | Original | / | 11/1/2024 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2080580 |
Floodplain | Original | N | 11/1/2024 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6331204008) | | Floodplain | 2080578 |