Energy | Original | D | 1/27/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2112821 |
Electrical | Original | D | 1/27/2025 | DANIELG | DANIELG | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2112820 |
Electronic Plan | Original | / | 1/27/2025 | DANIELG | DANIELG | In Current Review by DANIELG | | Electronic Plan | 2112814 |
CO Springs DRE | Original | A | 1/24/2025 | SSADLER | SSADLER | Approved for a water heater replacement. | | CO Springs DRE | 2112454 |
CO Springs Fire | Original | N | 1/24/2025 | CSFIRE | CSFIRE | No Fire Final | Jacob.Watson | CO Springs Fire | 2112370 |
CO Springs Hazmat | Original | N | 1/24/2025 | CSFIRE | CSFIRE | No Fire Final | Jacob.Watson | CO Springs Hazmat | 2112369 |
Mechanical | Original | N | 1/24/2025 | DALEH | DALEH | | | Mechanical | 2112281 |
Plumbing | Original | D | 1/24/2025 | SHANEN | SHANEN | Existing expansion tank installed on the hot water distribution side does not comply with section 607.3. Relocated water heater must comply with current code. Provide a thermal expansion control device on the water heater cold water supply pipe per section 607.3. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2112150 |
Zoning/Planning | Original | / | 1/24/2025 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2112138 |
CSU Water | Original | N | 1/24/2025 | CSUREVIEW | CSUREVIEW | No new water service outside of building. mjg | mgackle | CSU Water | 2112125 |
CSU Waste Water | Original | N | 1/24/2025 | CSUREVIEW | CSUREVIEW | No new wastewater service outside of building. mjg | mgackle | CSU Waste Water | 2112124 |
Enumeration | Original | D | 1/23/2025 | BRENT | BRENT | The area of work shown is labeled as 1036 but the plan was submitted as 1044. Include a site plan showing all tenant spaces in the building with addressing and the area of work highlighted. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2112079 |
Electronic Plan | Original | / | 1/23/2025 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 2112072 |
Energy | Original | / | 1/22/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2110873 |
Floodplain | Original | N | 1/22/2025 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 7324304005) | | Floodplain | 2110872 |