Energy | Original | D | 4/7/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2141365 |
Electrical | Original | D | 4/7/2025 | BERTHA | BERTHA | Provide fault current information (SCCR, AIC, SCA) in tabular format at all of the following locations. 1. All new panelboards and switchboards 2. All new transfer equipment 3. All new industrial control panels 4. All new air conditioning and refrigeration equipment 5. At any of the above locations when refed
Vestibules must be identified on plans as conditioned or unconditioned. If the vestibule is conditioned or an air curtain is specified, show compliance with C403.4.1.4.
Comply with C405.11 - 2021 IECC * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2141364 |
CO Springs Hazmat | Original | D | 4/3/2025 | CSFIRE | CSFIRE | | chiptaylor | CO Springs Hazmat | 2140234 |
CO Springs Fire | Original | D | 4/3/2025 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | chiptaylor | CO Springs Fire | 2140233 |
Mechanical | Original | D | 3/27/2025 | DALEH | DALEH | Provide a roof plan Show roof access Remove all items from floor plan that are on roof and show on roof plan Provide mechanical Comcheck See plans for comments * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2137019 |
Electronic Plan | Original | / | 3/27/2025 | BERTHA | BERTHA | In Current Review by BERTHA | | Electronic Plan | 2136931 |
Plumbing | Original | D | 3/25/2025 | SHANEN | SHANEN | Preliminary review. Compliance with 2021 IPC and CO state amendments to 2021 IPC must be stated on the plumbing plans. CSU approved construction drawings and utility service plan required to verify the plumbing plans correspond with the CSU approved plans for water service sizing, water entry location, building drain sizing, building drain location, etc. All gas piping related items shall be on the mechanical plans. Remove all references to gas piping from the plumbing plans. Provide gpm and/or square footage served by each component of the roof drainage system as this required information is not provided on the architectural plans. Provide a two way fitting or two riser clean-out at the junction of the building drain and building sewer in compliance with CO state amendment to section 708.1.3. Show compliance with additional requirements for 2021 IECC. Provided water pipe size analysis data is incomplete. Data must include: service pressure, service size, meter size, pressure loss, available pressure, distribution size, WSFU served, developed length, etc. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2135869 |
Elevators | Original | N | 3/25/2025 | ROBERTV | ROBERTV | No Conveyances | | Elevators | 2135813 |
EPC Health Dept | Original | D | 3/21/2025 | HEALTHDEPT | HEALTHDEPT | Construction activity permit required for projects earthmoving > 1 acre. If the entire project is > 1 acre earthmoving, regardless of being submitted in phases and/or separate building permits, a construction activity permit will be required. Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/construction-land-use/construction-activity-permit/. For questions, contact Environmental Health at 719-578-3199 option 3. MT | mtemple | EPC Health Dept | 2134829 |
City Engr | Original | D | 3/21/2025 | JDAGNILLO | JDAGNILLO | Include a copy of the approved Development Plan and a copy of the Stormwater Enterprise approved Grading & Erosion Control Plan in the electronic building permit set. (Project Dox #STM-REV24-1385)
There is a cost recovery assessed against this lot for the construction of Marksheffel Rd. This must be collected prior to building permit issuance. Please contact the master developer for this property to determine if this amount has been paid. | | City Engr | 2134762 |
CSU Water | Original | D | 3/18/2025 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set.
Refer to 2023 Colorado Springs Utilities WaterLESS details B4-1 through B4-8 and select the correct meter detail to include on the plumbing plans after approval of the Commercial Water Meter Sizing Form. Also refer to details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans.
Change of pipe material will not be allowed prior to the meter and backflow assembly. Sch 40 PVC is not a CSU approved water service line material. Remove Water Service Detail (7/P2) and utilize CSU standard details from the 2023 Edition of Water Line Extension and Service Standards instead. Contact Utilities Development Services at 719-668-8259 with any questions. CJS | cjsavage | CSU Water | 2132761 |
CSU Waste Water | Original | D | 3/18/2025 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. CJS | cjsavage | CSU Waste Water | 2132751 |
Gas/Elec. Utils | Original | D | 3/18/2025 | CSUREVIEW | CSUREVIEW | Approved Development Plan must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. CJS | cjsavage | Gas/Elec. Utils | 2132748 |
CO Springs DRE | Original | D | 3/18/2025 | SSADLER | SSADLER | Upload the final approved and stamped development plan. Make sure to include the final landscaping and irrigation plans. Upload the final recorded plat. All private financial assurances must be posted prior to building permit release. | | CO Springs DRE | 2132528 |
CSU Contract Admin. | Original | D | 3/18/2025 | CSUAPPSPRM | CSUAPPSPRM | Requires approved Commercial Water Meter Sizing Form (CWMSF) and paid utility receipt for applicable Development Charges/Fees. Contact Customer Contract Administration at 719-668-8111 to request an estimate. CWMSF available at: https://www.csu.org/extrx/util_dev_svcs/svc_standards/water/chapter/wp_8.pdf BS | bschifferstein | CSU Contract Admin. | 2132497 |
Zoning/Planning | Original | / | 3/18/2025 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2132467 |
Construction | Original | D | 3/18/2025 | BPHILLIPS | BPHILLIPS | Code data, life safety plan, PEMB drawings, roof framing plan. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2132464 |
Electronic Plan | Original | / | 3/13/2025 | BPHILLIPS | BPHILLIPS | In Current Review by BPHILLIPS | | Electronic Plan | 2130895 |
Enumeration | Original | D | 3/13/2025 | BRENT | BRENT | Include a detailed site plan in the architectural plan pages. show the elevation of the trash enclosure in the architectural plan pages. If needed, a separate address for this trash enclosure will be assigned at the next review based on the elevations included. Enumerations will not approve this plan without a copy of the final recorded plat in our records. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2130816 |
Electronic Plan | Original | / | 3/13/2025 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 2130810 |
Energy | Original | / | 3/5/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2127576 |
Floodplain | Original | N | 3/5/2025 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 5300000747) | | Floodplain | 2127575 |