CO Springs Hazmat | Original | N | 5/22/2025 | CSFIRE | CSFIRE | | phil.valdez | CO Springs Hazmat | 2161842 |
CO Springs Fire | Original | D | 5/22/2025 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | phil.valdez | CO Springs Fire | 2161841 |
Energy | Original | D | 5/16/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2159540 |
Mechanical | Original | D | 5/16/2025 | TCRIPPEN | TCRIPPEN | Disapproved: Provide refrigeration Isometric with sizing locations per the IMC section 1109 through 1109.7and condensation isometrics and sizes * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2159539 |
CO Springs DRE | Original | D | 5/14/2025 | SSADLER | SSADLER | Upload the approved stamped development plans. Upload the approval letter. Upload the final recorded plat. Financial assurances for private improvements must be posted prior to building permit release. | | CO Springs DRE | 2158805 |
City Engr | Original | D | 5/14/2025 | JDAGNILLO | JDAGNILLO | Include a copy of the approved Development Plan and a copy of both the Stormwater Enterprise approved Grading & Erosion Control Plan and Permanent Control Measure (Permanent Water Quality Facility) Plan in the electronic building permit set. (Project Dox #STM-REV22-0591 & 0614) | | City Engr | 2158480 |
CSU Contract Admin. | Original | D | 5/13/2025 | CSUAPPSPRM | CSUAPPSPRM | Requires approved Commercial Water Meter Sizing Form (CWMSF) and payment of applicable utility charges and fees. Please contact Customer Contract Administration at 719-668-8111 for additional information on charges/fees and to request an estimate. CWMSF available online at:
https://www.csu.org/CSUDocuments/watermetersizingforminteractive.pdf
AMS | ASweet | CSU Contract Admin. | 2158128 |
Electrical | Original | D | 5/13/2025 | DANIELG | DANIELG | Please see link for electrical plan review requirements.
https://www.pprbd.org/File/ByAlias/ElectricalReview
* Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2157976 |
Electronic Plan | Original | / | 5/13/2025 | DANIELG | DANIELG | In Current Review by DANIELG | | Electronic Plan | 2157972 |
Plumbing | Original | D | 5/13/2025 | SHANEN | SHANEN | Preliminary review. Construction review and CSU comments must be addressed. All gas piping related items shall be on the mechanical plans. Remove ALL references to gas piping from the plumbing plans. Show compliance with commercial plumbing plan review additional requirements for 2021 IECC. Provide required water pipe size analysis data, see 2021 IPC appendix E. Data must include: service pressure, service size, meter size, pressure loss, available pressure, distribution size, WSFU served, developed length, etc. Show compliance with commercial plumbing plan review additional requirements for 2021 IECC. See link: https://www.pprbd.org/File/ByAlias/PlumbingReview CSU approved construction drawings and utility service plan required to verify the plumbing plans correspond with the CSU approved plans for water service sizing, water entry location, building drain sizing, building drain location, etc. Plumbing located in elevator machine room does not comply with section 301.6. Floor sink and waste serving floor sink are undersized to receive a minimum 50 gpm elevator sump discharge. Show piping serving secondary roof drains. Clarify how OSD piping is in compliance with section 1108. Roof drain piping materials must comply with section 1102.2. Remove all diagrams that do not apply to this building. Funnel drain in return air plenum does not comply with section 802.4. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2157913 |
Elevators | Original | D | 5/12/2025 | ROBERTV | ROBERTV | Need site specific shop drawings and power data for all elevators being installed. All elevator shop drawing and power data information must be situated in all of the required pages of this planset to include all work by others. Dimensions, notes and layouts must match in all trade pages. These submittals cannot be deferred and cannot use Basis of Design. Without these, a review cannot be performed and will continue to be disapproved
Also See Sheets: A0-0.0, A0-2.0, A2-35, A7-2, M-4.0.6, M-4.11.1, P-4.12, P-4.13., E-4.13, E-4.12 . * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Elevators | 2157908 |
EPC Health Dept | Original | D | 5/12/2025 | HEALTHDEPT | HEALTHDEPT | Construction activity permit required for projects earthmoving > 1 acre. If the entire project is > 1 acre earthmoving, regardless of being submitted in phases and/or separate building permits, a construction activity permit will be required. Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/construction-land-use/construction-activity-permit/. For questions, contact Environmental Health at 719-578-3199 option 3. BR
Sequence C201154 C201164 | brothrock | EPC Health Dept | 2157903 |
CSU Water | Original | D | 5/12/2025 | CSUREVIEW | CSUREVIEW | Requires CSU-approved wastewater and water mainline Construction Drawings (CD's) and approved Utility Service Plan (USP). Call UDS at 719-668-8259 with questions. Add the following detail callout to the plumbing plan set. Refer to 2023 Colorado Springs Utilities WaterLESS details B4-1 through B4-8 and select the correct meter detail to include on the plumbing plans after approval of the Commercial Water Meter Sizing Form. Also refer to details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans.MDA | malcuran | CSU Water | 2157880 |
CSU Waste Water | Original | D | 5/12/2025 | CSUREVIEW | CSUREVIEW | Requires CSU-approved wastewater and water mainline Construction Drawings (CD's) and approved Utility Service Plan (USP). Call UDS at 719-668-8259 with questions.MDA | malcuran | CSU Waste Water | 2157879 |
Gas/Elec. Utils | Original | D | 5/12/2025 | CSUREVIEW | CSUREVIEW | Requires CSU-approved wastewater and water mainline Construction Drawings (CD's) and approved Utility Service Plan (USP). Call UDS at 719-668-8259 with questions.MDA | malcuran | Gas/Elec. Utils | 2157878 |
Zoning/Planning | Original | / | 5/12/2025 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2157865 |
Construction | Original | D | 5/12/2025 | SHELLEY | SHELLEY | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2157838 |
Electronic Plan | Original | / | 5/8/2025 | CHRISTINEH | CHRISTINEH | In Current Review by CHRISTINEH | | Electronic Plan | 2156014 |
Enumeration | Original | D | 5/1/2025 | BECKYA | BECKYA | See plans for disapproval comments. Secondary addressing on floor plans and the site plan. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2153216 |
Electronic Plan | Original | / | 5/1/2025 | BECKYA | BECKYA | In Current Review by BECKYA | | Electronic Plan | 2153188 |
Floodplain | Original | N | 5/1/2025 | KEITH | KEITH | | | Floodplain | 2153091 |
Energy | Original | / | 4/30/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2152671 |