Tri-Lakes Fire (CSFD) | Original | D | 5/23/2025 | CSFIRE | CSFIRE | You are responsible for reviewing the comments through your ACA account. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. ALL PLAN APPROVALS SUBJECT TO FINAL INSPECTION! | chiptaylor | Tri-Lakes Fire (CSFD) | 2162568 |
Tri-Lakes Hazmat (CSFD) | Original | N | 5/23/2025 | CSFIRE | CSFIRE | | chiptaylor | Tri-Lakes Hazmat (CSFD) | 2162567 |
Monument Zoning | Original | D | 5/22/2025 | TOWNOFMON | TOWNOFMON | Still under review in Monument Planning Department. | bholtztom | Monument Zoning | 2161988 |
Monument Water | Original | D | 5/22/2025 | TOWNOFMON | TOWNOFMON | Still under review in Monument Planning Department. | bholtztom | Monument Water | 2161985 |
Energy | Original | D | 5/19/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2160295 |
Electrical | Original | D | 5/19/2025 | DANIELG | DANIELG | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2160294 |
Electronic Plan | Original | / | 5/19/2025 | DANIELG | DANIELG | In Current Review by DANIELG | | Electronic Plan | 2160271 |
Mechanical | Original | D | 5/16/2025 | DALEH | DALEH | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2159964 |
Electronic Plan | Original | / | 5/16/2025 | DALEH | DALEH | In Current Review by DALEH | | Electronic Plan | 2159927 |
Plumbing | Original | D | 5/15/2025 | SHANEN | SHANEN | Preliminary review. Compliance with 2021 IPC and CO state amendments to 2021 IPC must be stated on the plumbing plans. All gas piping related items must be on the mechanical plans. Remove all references to gas piping from the plumbing plans. Show compliance with commercial plumbing plan review additional requirements for 2021 IECC. Provide required water pipe size analysis data, see 2021 IPC appendix E. Data must include: service pressure, service size, meter size, pressure loss, available pressure, distribution size, WSFU served, developed length, etc. Elevator sump discharge shall comply with section 301.6 Exception: Floor drains, sumps and sump pumps shall be permitted at the base of the shaft, provided that they are indirectly connected to the plumbing system. Discharge elevator sump indirectly to a waste receptor capable of handling a minimum of 50 gpm (100 dfu). Sheet P5 enlarged plan 2 - 3/4" is undersized to serve downstream fixtures. Provide isometric drawings of the complete water distribution system. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2159462 |
Elevators | Original | D | 5/15/2025 | ROBERTV | ROBERTV | Need site specific shop drawings and power data for all elevators being installed. All elevator shop drawing and power data information must be situated in all of the required pages of this planset to include all work by others. Dimensions, notes and layouts must match in all trade pages. These submittals cannot be deferred and cannot use Basis of Design. Without these, a review cannot be performed and will continue to be disapproved
See sheets: A21, M13, E2, E7, P2, P4 . * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Elevators | 2159368 |
EPC Health Dept | Original | D | 5/14/2025 | HEALTHDEPT | HEALTHDEPT | Construction activity permit required for projects earthmoving > 1 acre. If the entire project is > 1 acre earthmoving, regardless of being submitted in phases and/or separate building permits, a construction activity permit will be required. Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/construction-land-use/construction-activity-permit/. For questions, contact Environmental Health at 719-578-3199 option 3. BR | brothrock | EPC Health Dept | 2158654 |
Construction | Original | D | 5/14/2025 | DOUGC | DOUGC | Life safety plan // Accessibility // Rated assemblies // IECC * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2158617 |
Electronic Plan | Original | / | 5/12/2025 | DOUGC | DOUGC | In Current Review by DOUGC | | Electronic Plan | 2157725 |
Enumeration | Original | A | 5/6/2025 | BECKYA | BECKYA | | | Enumeration | 2155272 |
Electronic Plan | Original | / | 5/6/2025 | BECKYA | BECKYA | In Current Review by BECKYA | | Electronic Plan | 2155250 |
Waste Water Div | Original | / | 5/5/2025 | SYSTEM | SYSTEM | You will need to contact Waste Water Div department for approval prior to permit. This department will not review the plan electronically. | | Waste Water Div | 2154262 |
Energy | Original | / | 5/5/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2154261 |
Floodplain | Original | N | 5/5/2025 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 7135006002) | | Floodplain | 2154259 |