CO Springs DRE | Original | A | 6/30/2025 | SSADLER | SSADLER | Interior remodel only. No change in footprint, No change in parking. No change in occupancy. | | CO Springs DRE | 2178456 |
EPC Health Dept | Original | D | 6/27/2025 | HEALTHDEPT | HEALTHDEPT | Retail food establishment plan review required. Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/retail-food/retail-food-establishments/. Please email application and all required documents to heaenvironmental@elpasoco.com. For questions, contact Environmental Health at 719-578-3199 option 3. BR | brothrock | EPC Health Dept | 2177672 |
Plumbing | Original | D | 6/26/2025 | SHANEN | SHANEN | Restroom location does not comply with section 403.3.1. Water heater detail must show compliance with 2021 IECC section 404.3. Water heater schedule must show efficiency requirements are met per section C404.2. Add the following note: A Final Commissioning Report shall be delivered to the building owner per section C408.2.5 of the 2021 IECC. Provided water pipe size analysis data is incomplete. Data must include: service pressure, service size, meter size, pressure loss, available pressure, distribution size, WSFU served, developed length, etc. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2177194 |
Mechanical | Original | D | 6/25/2025 | DALEH | DALEH | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2176843 |
CSU Water | Original | N | 6/25/2025 | CSUREVIEW | CSUREVIEW | No new water service outside of building. MLW | mlwilliams | CSU Water | 2176779 |
CSU Waste Water | Original | A | 6/25/2025 | CSUREVIEW | CSUREVIEW | Addition of hand sinks to existing grease waste line is acceptable. MLW | mlwilliams | CSU Waste Water | 2176777 |
Electrical | Original | D | 6/25/2025 | RICHG | RICHG | Panel A feeds panel CS where is CS?
Provide SCA and SCCR for all new or re-fed refrigeration equipment
Comply with C405.11 IECC 2021
. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2176645 |
Zoning/Planning | Original | / | 6/25/2025 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2176597 |
Construction | Original | D | 6/25/2025 | BRIANB | BRIANB | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2176536 |
Energy | Original | N | 6/25/2025 | SYSTEM | SYSTEM | Energy Department review not required under 2023 PPRBC when IECC is N/A | | Energy | 2176361 |
Electronic Plan | Original | / | 6/25/2025 | BRIANB | BRIANB | In Current Review by BRIANB | | Electronic Plan | 2176343 |
Enumeration | Original | N | 6/23/2025 | AMY | AMY | | | Enumeration | 2175260 |
Electronic Plan | Original | / | 6/23/2025 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 2175242 |
Energy | Original | / | 6/23/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2175173 |
Floodplain | Original | N | 6/23/2025 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6416106024) | | Floodplain | 2175172 |