| Energy | Original | D | 10/29/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2230429 |
| Electrical | Original | A | 10/29/2025 | BERTHA | BERTHA | | | Electrical | 2230428 |
| Electronic Plan | Original | / | 10/29/2025 | BERTHA | BERTHA | In Current Review by BERTHA | | Electronic Plan | 2229995 |
| CO Springs DRE | Original | D | 10/28/2025 | SSADLER | SSADLER | Previous comments not addressed. Upload the approval letter for the development plan. Financial assurances for private improvements must be posted. All other city wide fees must be paid prior to building permit issuance.
Approved dp, recorded plat, and final landscaping and irrigation plans stamped and on file. | | CO Springs DRE | 2229881 |
| City Engr | Original | D | 10/28/2025 | HVO | HVO | Please see previous comment- include a copy of the approved the Stormwater Enterprise approved Grading & Erosion Control Plan in the electronic building permit set | | City Engr | 2229790 |
| EPC Health Dept | Original | D | 10/28/2025 | HEALTHDEPT | HEALTHDEPT | Construction activity permit required for projects earthmoving > 1 acre. If the entire project is > 1 acre earthmoving, regardless of being submitted in phases and/or separate building permits, a construction activity permit will be required. Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/construction-land-use/construction-activity-permit/. For questions, contact Environmental Health at 719-578-3199 option 3. AM | Amanda Furno | EPC Health Dept | 2229735 |
| CSU Contract Admin. | Original | D | 10/27/2025 | CSUAPPSPRM | CSUAPPSPRM | Requires approved Commercial Water Meter Sizing Form (CWMSF) and paid utility receipt for applicable Development Charges/Fees. Contact Customer Contract Administration at 719-668-8111 to request an estimate. CWMSF available at: https://www.csu.org/extrx/util_dev_svcs/svc_standards/water/chapter/wp_8.pdf
BS | bschifferstein | CSU Contract Admin. | 2229371 |
| Zoning/Planning | Original | / | 10/27/2025 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2229267 |
| CSU Waste Water | Original | D | 10/27/2025 | CSUREVIEW | CSUREVIEW | CSU-approved Construction and/or Utility Service Plan Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. DMM | dmakings | CSU Waste Water | 2229201 |
| CSU Water | Original | D | 10/27/2025 | CSUREVIEW | CSUREVIEW | CSU-approved Construction and/or Utility Service Plan Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. DMM | dmakings | CSU Water | 2229198 |
| Mechanical | Original | A | 10/27/2025 | TREVORH | TREVORH | Approved; | | Mechanical | 2229193 |
| Plumbing | Original | D | 10/27/2025 | SHANEN | SHANEN | Piping insulation material schedule must include material (fiberglass, elastomeric foam, etc.) and manufacturer. CSU approved construction drawings and utility service plan required to verify the plumbing plans correspond with the CSU approved plans for water service sizing, water entry location, building drain sizing, building drain location, etc. Heated water supply piping shall comply with 2021 IECC section C404.5.1. Lavatories must show compliance with 2021 IECC section C404.5.1. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2229132 |
| Construction | Original | D | 10/27/2025 | BPHILLIPS | BPHILLIPS | Revise site plan per note * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2229102 |
| Electronic Plan | Original | / | 10/27/2025 | BPHILLIPS | BPHILLIPS | In Current Review by BPHILLIPS | | Electronic Plan | 2229049 |
| Enumeration | Original | D | 10/27/2025 | BECKYA | BECKYA | A wrecking permit to remove the existing structure is required to be in place prior to approval of this plan in the Enumeration department. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2228835 |
| | Original | / | 10/26/2025 | SYSTEM | SYSTEM | Resubmittal Processing Fee(s) Paid | | | 2228832 |
| | Original | / | 10/23/2025 | SYSTEM | SYSTEM | Resubmittal Processing Fee Due | | | 2228034 |
| Submittal 3 | Original | / | 10/23/2025 | QUINTONW | QUINTONW | Submittal #3 | | Submittal 3 | 2228033 |
| CO Springs Fire | Original | D | 10/8/2025 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | michael.davis1@color | CO Springs Fire | 2221471 |
| Energy | Original | D | 10/8/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2221283 |
| Electrical | Original | D | 10/8/2025 | BERTHA | BERTHA | Comply with previous review comment - Provide available fault current and withstand rating for new air conditioning/refrigeration equipment. Provide this information on the electrical plans.
Comply with previous review comment - Recessed lighting must be shown on the lighting schedule and comply with C402.5.10. Show information on the electrical plans.
Comply with previous review comment - Vestibules must be identified on plans as conditioned or unconditioned. If the vestibule is conditioned or an air curtain is specified, show compliance with C403.4.1.4. Show information on the electrical plans. . * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2221282 |
| Electronic Plan | Original | / | 10/8/2025 | BERTHA | BERTHA | In Current Review by BERTHA | | Electronic Plan | 2220933 |
| Plumbing | Original | D | 10/7/2025 | SHANEN | SHANEN | Show compliance with commercial plumbing plan review additional requirements for 2021 IECC. See clouds. CSU comments must be addressed. Provided water pipe size analysis data is incomplete. Water heater detail must show compliance with 2021 IECC section 404.3. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2220399 |
| CO Springs DRE | Original | D | 10/6/2025 | SSADLER | SSADLER | Previous comments not addressed. Upload the final recorded plat. Upload the approval letter for the development plan. Financial assurances for private improvements must be posted. All other city wide fees must be paid prior to building permit issuance.
Approved dp and final landscaping and irrigation plans stamped and on file. | | CO Springs DRE | 2219800 |
| Mechanical | Original | D | 10/6/2025 | TREVORH | TREVORH | Disapproved; Comment form the 1st review : Still need to see the signed and stamped MechComCheck * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2219758 |
| City Engr | Original | D | 10/3/2025 | HVO | HVO | Please see previous comment- include a copy of the approved the Stormwater Enterprise approved Grading & Erosion Control Plan | | City Engr | 2219475 |
| Zoning/Planning | Original | / | 10/3/2025 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2219117 |
| CSU Contract Admin. | Original | D | 10/2/2025 | CSUAPPSPRM | CSUAPPSPRM | Requires approved Commercial Water Meter Sizing Form (CWMSF) and payment of applicable utility charges and fees. Please contact Customer Contract Administration at 719-668-8111 for additional information on charges/fees and to request an estimate.
CWMSF was received, but requires corrections.
AMS | ASweet | CSU Contract Admin. | 2219051 |
| EPC Health Dept | Original | D | 10/2/2025 | HEALTHDEPT | HEALTHDEPT | Construction activity permit required for projects earthmoving > 1 acre. If the entire project is > 1 acre earthmoving, regardless of being submitted in phases and/or separate building permits, a construction activity permit will be required. Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/construction-land-use/construction-activity-permit/. For questions, contact Environmental Health at 719-578-3199 option 3. TG | tguerrero | EPC Health Dept | 2219029 |
| CSU Water | Original | D | 10/2/2025 | CSUREVIEW | CSUREVIEW | See previous comments. Requires CSU-approved wastewater and water mainline Construction Drawings (CD's) and approved Utility Service Plan (USP). Call UDS at 719-668-8259 with questions. Refer to 2023 Colorado Springs Utilities WaterLESS details B4-1 through B4-8 and select the correct meter detail to include on the plumbing plans after approval of the Commercial Water Meter Sizing Form. Also refer to details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans. mjg | mgackle | CSU Water | 2218955 |
| CSU Waste Water | Original | D | 10/2/2025 | CSUREVIEW | CSUREVIEW | See previous comments. Requires CSU-approved wastewater and water mainline Construction Drawings (CD's) and approved Utility Service Plan (USP). Call UDS at 719-668-8259 with questions. mjg | mgackle | CSU Waste Water | 2218954 |
| Construction | Original | D | 10/2/2025 | BPHILLIPS | BPHILLIPS | While a B occupancy, occupant load factor is determined by use of the space. Revise to 1:15 upon resubmittal. Provide measurements to indicate fire separation distances. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2218897 |
| Electronic Plan | Original | / | 10/2/2025 | BPHILLIPS | BPHILLIPS | In Current Review by BPHILLIPS | | Electronic Plan | 2218883 |
| Enumeration | Original | D | 10/2/2025 | BECKYA | BECKYA | A wrecking permit to remove the existing structure is required to be in place prior to approval of this plan in the Enumeration department. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2218737 |
| Submittal 2 | Original | / | 10/2/2025 | QUINTONW | QUINTONW | Submittal #2 | | Submittal 2 | 2218644 |
| Electrical | Original | D | 9/15/2025 | BERTHA | BERTHA | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2211054 |
| Energy | Original | D | 9/15/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2211055 |
| Electronic Plan | Original | / | 9/15/2025 | BERTHA | BERTHA | In Current Review by BERTHA | | Electronic Plan | 2210882 |
| Plumbing | Original | D | 9/10/2025 | SHANEN | SHANEN | Show compliance with commercial plumbing plan review additional requirements for 2021 IECC. Provide required water pipe size analysis data, see 2021 IPC appendix E. Provide a piping materials schedule. PPRBD does not enforce ADA, reference ICC A117.1-2017. KW/Volts are illegible. CSU approved construction drawings and utility service plan required to verify the plumbing plans correspond with the CSU approved plans for water service sizing, water entry location, building drain sizing, building drain location, etc. All gas piping and condensate piping related items shall be on the mechanical plans. Remove ALL references to gas piping and condensate piping from the plumbing plans. Heated water supply piping shall comply with 2021 IECC section C404.5. Lavatories must show compliance with 2021 IECC section C404.5.1. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2209025 |
| Mechanical | Original | D | 9/10/2025 | TREVORH | TREVORH | Disapproved; Need to show all Gas related items on mechanical sheets, meter location piping size,Material and whichtable from the IFGC was used for sizing.Need to show on plans how mechanical equipment will be Accessed. Need to see MECHANICAL COMCHECK * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2208816 |
| CO Springs Fire | Original | D | 9/10/2025 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | phil.valdez | CO Springs Fire | 2208790 |
| CO Springs Hazmat | Original | N | 9/10/2025 | CSFIRE | CSFIRE | | phil.valdez | CO Springs Hazmat | 2208787 |
| Elevators | Original | N | 9/9/2025 | ROBERTV | ROBERTV | No Conveyances | | Elevators | 2208703 |
| CO Springs DRE | Original | D | 9/8/2025 | SSADLER | SSADLER | Upload the approval letter. Upload the final recorded plat. Financial assurances for all private improvements must be posted. Other fees may be owed prior to building permit issuance.
DP is on file and stamped. | | CO Springs DRE | 2207884 |
| EPC Health Dept | Original | D | 9/5/2025 | HEALTHDEPT | HEALTHDEPT | Construction activity permit required for projects earthmoving > 1 acre. If the entire project is > 1 acre earthmoving, regardless of being submitted in phases and/or separate building permits, a construction activity permit will be required. Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/construction-land-use/construction-activity-permit/. For questions, contact Environmental Health at 719-578-3199 option 3. MT | mtemple | EPC Health Dept | 2207456 |
| City Engr | Original | D | 9/5/2025 | JDAGNILLO | JDAGNILLO | Include a copy of the Stormwater Enterprise approved Grading & Erosion Control Plan in the electronic building permit set. (Project Dox #STM-REV25-0248) | | City Engr | 2207114 |
| CSU Water | Original | D | 9/4/2025 | CSUREVIEW | CSUREVIEW | Requires CSU-approved wastewater and water mainline Construction Drawings (CD's) and approved Utility Service Plan (USP). Call UDS at 719-668-8259 with questions.
Refer to 2023 Colorado Springs Utilities WaterLESS details B4-1 through B4-8 and select the correct meter detail to include on the plumbing plans after approval of the Commercial Water Meter Sizing Form. Also refer to details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans. mjg | mgackle | CSU Water | 2206911 |
| CSU Waste Water | Original | D | 9/4/2025 | CSUREVIEW | CSUREVIEW | Requires CSU-approved wastewater and water mainline Construction Drawings (CD's) and approved Utility Service Plan (USP). Call UDS at 719-668-8259 with questions. mjg | mgackle | CSU Waste Water | 2206910 |
| Gas/Elec. Utils | Original | A | 9/4/2025 | CSUREVIEW | CSUREVIEW | CSU Field Engineer to determine final gas/electric meter, transformer and service line locations. Contact Field Engineering at 719-668-4985 (Gas) or 719-668-5564 (Electric) with any questions. mjg | mgackle | Gas/Elec. Utils | 2206908 |
| Zoning/Planning | Original | / | 9/4/2025 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2206843 |
| CSU Contract Admin. | Original | D | 9/4/2025 | CSUAPPSPRM | CSUAPPSPRM | Requires approved Commercial Water Meter Sizing Form (CWMSF) and paid utility receipt for applicable Development Charges/Fees. Contact Customer Contract Administration at 719-668-8111 to request an estimate.
CWMSF available at: https://www.csu.org/extrx/util_dev_svcs/svc_standards/water/chapter/wp_8.pdf
BS | bschifferstein | CSU Contract Admin. | 2206816 |
| Construction | Original | D | 9/4/2025 | BPHILLIPS | BPHILLIPS | Life safety plan, occupant load. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2206800 |
| Electronic Plan | Original | / | 9/3/2025 | BPHILLIPS | BPHILLIPS | In Current Review by BPHILLIPS | | Electronic Plan | 2206044 |
| Enumeration | Original | D | 8/29/2025 | AMY | AMY | 1. Since this is a ground up bank, a wrecking permit to remove the existing structure will be required to be in place prior to approval of this plan in the Enumerations department.
2.The legal description and tax schedule number are required to be on the Code Study form. This information is associated with the property and can be found on the El Paso County Assessors web site.
3. Add the north arrow to the site plan on page A00.60.
4. Signs will be on a separate application. Cross out the sign information on the plan or remove. Please contact Development Review Enterprise for sign submittal. Kurt Schmitt kurt.schmitt@coloradosprings.gov * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2205196 |
| Electronic Plan | Original | / | 8/29/2025 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 2205184 |
| Energy | Original | / | 8/28/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2204851 |
| Floodplain | Original | N | 8/28/2025 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6410401008) | | Floodplain | 2204850 |