| Energy | Original | D | 10/27/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2228893 |
| Construction | Original | D | 10/27/2025 | DOUGC | DOUGC | CSF // Accessibility // Rated assemblies * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2228864 |
| Electronic Plan | Original | / | 10/22/2025 | DOUGC | DOUGC | In Current Review by DOUGC | | Electronic Plan | 2227716 |
| Energy | Original | / | 10/22/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2227714 |
| Enumeration | Original | D | 10/22/2025 | BECKYA | BECKYA | Secondary addressing provided does not meet Enumeration guidelines, unit numbers need to match with numbers across the hall, even on one side odd on the other, okay to skip unit numbers to have them match. Please email Becky Allen (beckya@pprbd.org) to assist if you need help.
We asked for this to be provided when we reviewed the Development Plan DEPN-25-0046 to prevent delays in Enumeration plan review. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2227121 |
| Energy | Original | / | 10/22/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2227061 |
| Energy | Original | D | 10/17/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2225329 |
| Mechanical | Original | D | 10/17/2025 | TCRIPPEN | TCRIPPEN | Disapproved: All gas piping and condensate piping related items shall be on the mechanical plans. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2225328 |
| CO Springs Fire | Original | D | 10/15/2025 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | chiptaylor | CO Springs Fire | 2224202 |
| CO Springs Hazmat | Original | D | 10/15/2025 | CSFIRE | CSFIRE | | chiptaylor | CO Springs Hazmat | 2224201 |
| Electrical | Original | D | 10/14/2025 | BERTHA | BERTHA | Multi-meter services must include a list of enumerated addresses on the one-line diagram. Pending approval in Elevators - See Elevator review comments. Provide elevator horsepower on the one line. Provide elevator feeder size, type, and quantity on the one line. Provide elevator over current device size ( Ampacity) on the one line. Provide all conductor size, type and quantity. Provide fault current information (SCCR, AIC, SCA) in tabular format at all of the following locations. 1. All new panelboards and switchboards 2. All new transfer equipment 3. All new industrial control panels 4. All new air conditioning and refrigeration equipment Provide footprint (site plan) showing all electrical service equipment and disconnects serving the structure Comply with 240.6 NEC Provide Colorado Springs Utilities Approval for indoor metering. Provide electrical plans with room names on them.
Complete re-review necessary
. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2224034 |
| Plumbing | Original | D | 10/14/2025 | SHANEN | SHANEN | Preliminary review. Architectural plan set did not include an overall floor plan for each floor to verify matching backgrounds. Provide an occupant load to fixture count analysis for the A and S occupancies to verify compliance with section 403.1. All gas piping and condensate piping related items shall be on the mechanical plans.Remove all references to gas piping and condensate piping from the plumbing plans. Show compliance with commercial plumbing plan review additional requirements for 2021 IECC. CSU approved construction drawings and utility service plan required to verify the plumbing plans correspond with the CSU approved plans for water service sizing, water entry location, building drain sizing, building drain location, etc. Provide a two way fitting or two riser clean-out at the junction of the building drain and building sewer in compliance with CO state amendment to section 708.1.3. Provide DFU served by each combined section of the building drain.Provide sizing for each branch of the building drain serving multiple fixtures. Clarify how basement fixtures are compliant with section 714. Show piping for the roof drainage system. Provide gpm and/or square footage served by each component of the roof drainage system. Architectural plans indicate a flat roof and roof drains are shown on the plumbing roof plan. Waste receptor (hub drain) locations do not comply with section 802.4. Condensate drain does not comply with section 1002.1 and does not match sheet P5.02D thru P5.05D riser diagrams as drawn. Provide sizing for each domestic water riser section serving multiple units. Provided water pipe size analysis data is incomplete. Schedule all plumbing fixtures on the plumbing plans per PPRBD plan review requirements. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2223678 |
| Electronic Plan | Original | / | 10/14/2025 | BERTHA | BERTHA | In Current Review by BERTHA | | Electronic Plan | 2223513 |
| Elevators | Original | D | 10/14/2025 | ROBERTV | ROBERTV | See sheets: A8-4.5, M6-4.1, E2-4.1L, E2-4.2L, E2-4.3L, E2-4.5L, E2-4.5S, E4-4.0, E7-4.0
RBD Note: (BLDG 1) - Kone Shop Drawings provided for (2) 3500 lb/ 150 fpm Machine Room-Less Traction Elevator, no Generator. A17.1 - 2019, 2023 RBC . * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Elevators | 2223487 |
| CO Springs DRE | Original | D | 10/8/2025 | SSADLER | SSADLER | Upload the approval letter. Upload the final recorded plat. Upload the final approved landscaping and irrigation plans. Financial assurances for private improvements must be posted. Other city wide fees may be due prior to building permit issuance. | | CO Springs DRE | 2220907 |
| CSU Waste Water | Original | D | 10/7/2025 | CSUREVIEW | CSUREVIEW | CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. DMM | dmakings | CSU Waste Water | 2220685 |
| CSU Water | Original | D | 10/7/2025 | CSUREVIEW | CSUREVIEW | CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions.
Refer to 2023 Colorado Springs Utilities WaterLESS details B4-1 through B4-8 and select the correct meter detail to include on the plumbing plans after approval of the Commercial Water Meter Sizing Form. Also refer to details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans. DMM | dmakings | CSU Water | 2220680 |
| Gas/Elec. Utils | Original | A | 10/7/2025 | CSUREVIEW | CSUREVIEW | CSU Field Engineer to determine final gas/electric meter, transformer and service line locations. Contact Field Engineering at 719-668-4985 (Gas) or 719-668-5564 (Electric) with any questions.DMM | dmakings | Gas/Elec. Utils | 2220679 |
| EPC Health Dept | Original | D | 10/7/2025 | HEALTHDEPT | HEALTHDEPT | Construction activity permit required for projects earthmoving > 1 acre. If the entire project is > 1 acre earthmoving, regardless of being submitted in phases and/or separate building permits, a construction activity permit will be required. Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/construction-land-use/construction-activity-permit/. For questions, contact Environmental Health at 719-578-3199 option 3. KB | KBauer | EPC Health Dept | 2220380 |
| CSU Contract Admin. | Original | D | 10/7/2025 | CSUAPPSPRM | CSUAPPSPRM | Requires approved Commercial Water Meter Sizing Form (CWMSF) and payment of applicable utility charges and fees. Please contact Customer Contract Administration at 719-668-8111 for additional information on charges/fees and to request an estimate. CWMSF available online at:
https://www.csu.org/CSUDocuments/watermetersizingforminteractive.pdf
AMS | ASweet | CSU Contract Admin. | 2220229 |
| City Engr | Original | D | 10/6/2025 | HVO | HVO | Please include a copy of the approved the Stormwater Enterprise approved Grading & Erosion Control Plan in the electronic building permit set | | City Engr | 2220052 |
| Zoning/Planning | Original | / | 10/6/2025 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2219785 |
| Construction | Original | D | 10/6/2025 | DOUGC | DOUGC | Missing sheets for architectural and accessibility categories // Preliminary review only * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2219700 |
| Electronic Plan | Original | / | 10/6/2025 | DOUGC | DOUGC | In Current Review by DOUGC | | Electronic Plan | 2219607 |
| Enumeration | Original | D | 10/3/2025 | BECKYA | BECKYA | It appears the Architectural Plans set is incomplete. Site plan and secondary addressing plans are missing from the Architectural Plans. Please provide an Accessibility Site plan in the Accessibility plans. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2219342 |
| Electronic Plan | Original | / | 10/2/2025 | BECKYA | BECKYA | In Current Review by BECKYA | | Electronic Plan | 2218816 |
| | Original | / | 10/2/2025 | SYSTEM | SYSTEM | Plan Review fees paid 10/02/2025 for plan submitted 09/26/2025. Submit Date updated to now. Plan now open for review. | | | 2218789 |
| Energy | Original | / | 9/26/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2216614 |
| Floodplain | Original | N | 9/26/2025 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 7414110004) | | Floodplain | 2216613 |