| CO Springs Hazmat | Original | A | 1/16/2026 | CSFIRE | CSFIRE | Deferred Submittal for CO2. CO2 installing contractor must submit plans directly to CSFD for review, approval and inspection PRIOR TO C of O. | smitty91 | CO Springs Hazmat | 2257437 |
| CO Springs Hazmat | Original | A | 1/16/2026 | CSFIRE | CSFIRE | Deferred Submittal for CO2. CO2 installing contractor must submit plans directly to CSFD for review, approval and inspection PRIOR TO C of O. | smitty91 | CO Springs Hazmat | 2257436 |
| CO Springs Fire | Original | D | 1/14/2026 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | michael.davis1@color | CO Springs Fire | 2256245 |
| CO Springs DRE | Original | D | 1/13/2026 | SSADLER | SSADLER | Add the tax schedule number to the code study form. Fees may be due for the change in occupancy. Contact Charla at charla.hudspeth@coloradosprings.gov | | CO Springs DRE | 2255718 |
| CSU Water | Original | N | 1/8/2026 | CSUREVIEW | CSUREVIEW | No new water service outside of building. PSD | PDosch | CSU Water | 2254754 |
| CSU Waste Water | Original | D | 1/8/2026 | CSUREVIEW | CSUREVIEW | A Utility Service Plan will be required for this project. Contact Utilities Development Services at (719) 668-8259 to discuss requirements. PSD | PDosch | CSU Waste Water | 2254751 |
| Energy | Original | D | 1/8/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2254679 |
| Electrical | Original | D | 1/8/2026 | CONNERM | CONNERM | -Fault current information (SCCR, AIC, SCA) at all of the following locations. 1. All new panelboards and switchboards2. All new transfer equipment3. All new industrial control panels -Vestibules must be identified on plans as conditioned or unconditioned. If the vestibule is conditioned or an air curtain is specified, show compliance with C403.4.1.4. -Provide a note on the Electrical Plan specifying refrigeration performance per C403.11 and C403.11.3 -Provide a note on the plans indicating that the Electrical design has a maximum volt drop of 5% per C405.10. -The following general note must be included on the electrical plans: “A Final Commissioning Report shall be delivered to the building owner per section C408.2.5 of the 2021 IECC.” -Controlled receptacles must be shown on the plan per C405.11 and the symbol used to mark these receptacles must be as shown in article 406.3(E) of the adopted National ElectricalWhere applicable, -Daylight Zones must be shown on the plans per C405.2.4.2 through C405.2.4.4. -Panel schedules show 225A bus rating on MLO panels. One-line must reflect this * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2254678 |
| EPC Health Dept | Original | D | 1/8/2026 | HEALTHDEPT | HEALTHDEPT | Retail food establishment plan review is in process and not yet approved. If your assigned plan reviewer has questions, they will contact you directly. For questions, contact Environmental Health at 719-578-3199 option 3. AM | Amanda Furno | EPC Health Dept | 2254625 |
| Mechanical | Original | D | 1/8/2026 | TREVORH | TREVORH | Disapproved; Need to see construction review comments addressed * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2254561 |
| Electronic Plan | Original | / | 1/8/2026 | CONNERM | CONNERM | In Current Review by CONNERM | | Electronic Plan | 2254535 |
| Electronic Plan | Original | / | 1/8/2026 | BERTHA | BERTHA | In Current Review by BERTHA | | Electronic Plan | 2254534 |
| Electronic Plan | Original | / | 1/8/2026 | TREVORH | TREVORH | In Current Review by TREVORH | | Electronic Plan | 2254533 |
| Plumbing | Original | D | 1/8/2026 | SHANEN | SHANEN | Compliance with 2021 IPC and CO state amendments to 2021 IPC must be stated on the plumbing plans. See clouded sections on additional requirements for 2021 IECC block. CSU approved construction drawings and/or utility service plan required to verify the plumbing plans correspond with the CSU approved plans for building drain sizing, building drain location, grease interceptor location, etc. Water heater detail must show compliance with IECC section C404.3. Show compliance with section 802. Water heater detail must show compliance with IECC section C404.3. Provide a water heater schedule on the plumbing plans. Provide an isometric drawing of the water distribution system. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2254511 |
| Zoning/Planning | Original | / | 1/8/2026 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2254508 |
| Construction | Original | D | 1/7/2026 | DOUGC | DOUGC | Code Study Form // Life Safety Plan // Structural * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2254474 |
| Electronic Plan | Original | / | 12/29/2025 | DOUGC | DOUGC | In Current Review by DOUGC | | Electronic Plan | 2251453 |
| Enumeration | Original | D | 12/12/2025 | AMY | AMY | 1710 Briargate Blvd is all under a single legal description and tax schedule number. What is shown as the legal description is incorrect. The ten digit number can be found on the El Paso County Assessor’s data base above the property address. Add this information to the Code Study form. https://property.spatialest.com/co/elpaso/#/ Update this information. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2246959 |
| Electronic Plan | Original | / | 12/12/2025 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 2246935 |
| Floodplain | Original | N | 12/11/2025 | KEITH | KEITH | | | Floodplain | 2246842 |
| | Original | / | 12/11/2025 | SYSTEM | SYSTEM | Plan Review fees paid 12/11/2025 for plan submitted 12/11/2025. Submit Date updated to now. Plan now open for review. | | | 2246743 |
| Energy | Original | / | 12/11/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2246738 |
| Floodplain | Original | / | 12/11/2025 | RBD GIS | RBD GIS | Autogenerated Review: Parcel intersects with 100 Year Floodplain. (Parcel: 6305401039) | | Floodplain | 2246736 |