| City Engr | Original | D | 2/3/2026 | HVO | HVO | Please include a copy of the approved the Stormwater Enterprise approved Grading & Erosion Control Plan, and a copy of the approved Stormwater Enterprise approved Permanent Control Measures in the electronic building permit set | | City Engr | 2262862 |
| Electrical | Original | D | 2/2/2026 | DANIELG | DANIELG | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2262163 |
| Plumbing | Original | D | 2/2/2026 | SHANEN | SHANEN | Preliminary review. Compliance with 2021 IPC and CO state amendments to 2021 IPC must be stated on the plumbing plans. Provide an occupant load fixture count analysis for each occupancy type to verify compliance with section 403.1. Show compliance with commercial plumbing plan review additional requirements for 2021 IECC. Provide a two way fitting or two riser clean-out at the junction of the building drain and building sewer in compliance with CO state amendment to section 708.1.3. CSU approved construction drawings and utility service plan required to verify the plumbing plans correspond with the CSU approved plans for water service sizing, water entry location, building drain sizing, building drain location, etc. All gas piping and condensate piping related items shall be on the mechanical plans. Remove all references to gas piping and condensate piping from the plumbing plans. Provide a pavilion plumbing plan to show DF-2 location and piping. Pavilion and storage building must show compliance with section 403.1. RPBFP required. ST-12 is for residential use only per manufacturer. All fixtures must be scheduled with manufacturer model numbers on the plumbing plans per PPRBD plan review requirements. Provide a piping materials schedule on the plumbing plans per PPRBD plan review requirements. Provide required water pipe size analysis data, see 2021 IPC appendix E. Data must include: service pressure, service size, meter size, pressure loss, available pressure, distribution size, WSFU served, developed length, etc. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2262121 |
| Electronic Plan | Original | / | 2/2/2026 | DANIELG | DANIELG | In Current Review by DANIELG | | Electronic Plan | 2262101 |
| Elevators | Original | N | 2/2/2026 | ANDREAL | ANDREAL | No conveyance in this scope of work. | | Elevators | 2261991 |
| CO Springs Fire | Original | D | 1/29/2026 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | chiptaylor | CO Springs Fire | 2261372 |
| CO Springs Hazmat | Original | N | 1/29/2026 | CSFIRE | CSFIRE | | chiptaylor | CO Springs Hazmat | 2261371 |
| CSU Contract Admin. | Original | D | 1/29/2026 | CSUAPPSPRM | CSUAPPSPRM | Commercial Water Meter Sizing Form (CWMSF) approved. Requires payment of applicable utility charges and fees. Please contact Customer Contract Administration at 719-668-8111 for additional information on charges/fees and to request an estimate.
AMS | ASweet | CSU Contract Admin. | 2261092 |
| CSU Water | Original | D | 1/29/2026 | CSUREVIEW | CSUREVIEW | CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. SSH | SHillman | CSU Water | 2261078 |
| CSU Waste Water | Original | D | 1/29/2026 | CSUREVIEW | CSUREVIEW | CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. SSH | SHillman | CSU Waste Water | 2261075 |
| Gas/Elec. Utils | Original | A | 1/29/2026 | CSUREVIEW | CSUREVIEW | Approved development plan provided with permit set.
CSU Field Engineer to determine final gas/electric meter, transformer and service line locations. Contact Field Engineering at 719-668-4985 (Gas) or 719-668-5564 (Electric) with any questions. SSH | SHillman | Gas/Elec. Utils | 2261071 |
| CO Springs DRE | Original | D | 1/29/2026 | SSADLER | SSADLER | Disapproved. The City is currently in receipt of two appeals for this development. In accordance with UDC Section 7.5.415.A.5 Stay of Decisions, no building permits shall be issued nor shall construction commence until final decisions are rendered by City Council. City Planning staff may have addition comments or corrections once review commences. All assurances and impact fees shall also be posted prior to building permit issuance.
Upload the following documents: 1. final recorded plat 2. final approved landscaping and irrigation plans.
Assurances for all private improvements must be posted prior to building permit issuance Citywide impact fees must be paid prior to building permit issuance | | CO Springs DRE | 2261055 |
| Zoning/Planning | Original | / | 1/29/2026 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2261054 |
| Construction | Original | D | 1/29/2026 | SHELLEY | SHELLEY | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2261049 |
| Electronic Plan | Original | / | 1/21/2026 | SHELLEY | SHELLEY | In Current Review by SHELLEY | | Electronic Plan | 2258452 |
| Enumeration | Original | A | 12/17/2025 | BRENT | BRENT | | | Enumeration | 2249396 |
| Electronic Plan | Original | / | 12/17/2025 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 2249336 |
| | Original | / | 12/17/2025 | SYSTEM | SYSTEM | Plan Review fees paid 12/17/2025 for plan submitted 12/15/2025. Submit Date updated to now. Plan now open for review. | | | 2249296 |
| Energy | Original | / | 12/15/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2247595 |
| Floodplain | Original | N | 12/15/2025 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6209303001) | | Floodplain | 2247594 |