| CO Springs Fire | Original | D | 6/10/2026 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | Jacob.Watson | CO Springs Fire | 2319337 |
| CO Springs Hazmat | Original | N | 6/10/2026 | CSFIRE | CSFIRE | NA | Jacob.Watson | CO Springs Hazmat | 2319336 |
| Energy | Original | D | 5/26/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2311819 |
| Mechanical | Original | D | 5/26/2026 | DALEH | DALEH | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2311818 |
| CO Springs DRE | Original | D | 5/22/2026 | SSADLER | SSADLER | The modification (DEPN-25-0162) is still in review. Once the plans are approved, upload the approved stamped plans and the approval letter. There may be fees owed. | | CO Springs DRE | 2311042 |
| City Engr | Original | D | 5/21/2026 | JDAGNILLO | JDAGNILLO | Include a copy of the Stormwater Enterprise approved Grading & Erosion Control Plan in the electronic building permit set. | | City Engr | 2310552 |
| Plumbing | Original | D | 5/21/2026 | SHANEN | SHANEN | Show compliance with commercial plumbing plan review additional requirements for 2021 IECC. CSU approved construction drawings and utility service plan required to verify the plumbing plans correspond with the CSU approved plans for water service sizing, water entry location, building drain sizing, building drain location, etc. Provide scupper opening dimensions and gpm/sq ft served. All required roof drainage information is not shown on sheet A-130 or A-501. Provide required water pipe size analysis data, see 2021 IPC appendix E. Data must include: service pressure, service size, meter size, pressure loss, available pressure, distribution size, WSFU served, developed length, etc. Provide a piping materials schedule. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2310407 |
| CSU Water | Original | D | 5/20/2026 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions.
ADD METER DETAILS TO PLUMBING PLAN
Refer to the current Colorado Springs Utilities WaterLESS details B4-1 through B4-8 and select the correct meter detail to include on the plumbing plans after approval of the Commercial Water Meter Sizing Form. Also refer to details B4-16 through B4-22 and select an appropriate meter clearance detail to include on the plumbing plans.MDA | malcuran | CSU Water | 2310115 |
| CSU Waste Water | Original | D | 5/20/2026 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions.MDA | malcuran | CSU Waste Water | 2310113 |
| Gas/Elec. Utils | Original | D | 5/20/2026 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions.MDA | malcuran | Gas/Elec. Utils | 2310112 |
| Zoning/Planning | Original | / | 5/20/2026 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2310040 |
| Electrical | Original | D | 5/20/2026 | DANIELG | DANIELG | * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2309965 |
| Electronic Plan | Original | / | 5/20/2026 | DANIELG | DANIELG | In Current Review by DANIELG | | Electronic Plan | 2309950 |
| Construction | Original | D | 5/20/2026 | DOUGC | DOUGC | Architectural Issues * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2309905 |
| Energy | Original | / | 5/19/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2309359 |
| Electronic Plan | Original | / | 5/19/2026 | DOUGC | DOUGC | In Current Review by DOUGC | | Electronic Plan | 2309185 |
| Enumeration | Original | N | 5/4/2026 | BECKYA | BECKYA | | | Enumeration | 2302691 |
| Floodplain | Original | A | 5/4/2026 | KEITH | KEITH | | | Floodplain | 2302622 |
| Electronic Plan | Original | / | 5/4/2026 | BECKYA | BECKYA | In Current Review by BECKYA | | Electronic Plan | 2302591 |
| | Original | / | 5/4/2026 | SYSTEM | SYSTEM | Plan Review fees paid 05/04/2026 for plan submitted 04/30/2026. Submit Date updated to now. Plan now open for review. | | | 2302568 |
| Energy | Original | / | 4/30/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2301103 |
| Floodplain | Original | / | 4/30/2026 | RBD GIS | RBD GIS | Autogenerated Review: Parcel intersects with 100 Year Floodplain. (Parcel: 6430214012) | | Floodplain | 2301102 |