| CO Springs Hazmat | Original | N | 7/1/2026 | CSFIRE | CSFIRE | | phil.valdez | CO Springs Hazmat | 2329809 |
| CO Springs Fire | Original | D | 7/1/2026 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | phil.valdez | CO Springs Fire | 2329789 |
| Energy | Original | D | 6/15/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2321448 |
| Electrical | Original | D | 6/15/2026 | DANIELG | DANIELG | Controlled receptacles must be shown on the plan per C405.11 * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2321447 |
| Mechanical | Original | D | 6/15/2026 | TREVORH | TREVORH | Disapproved; Mechanical Equipment not permissible in the Elevator Hoistway * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2320971 |
| Plumbing | Original | D | 6/15/2026 | SHANEN | SHANEN | EWC does not comply with section 410.3. 3/4" DCW is undersized to serve multiple restroom fixtures. 2" FD with a 2" trap and 2" waste is undersized to serve a minimum 50 gpm elevator sump discharge. Provide a DWV riser diagram or isometric drawing. Provide sizing for each branch of the water distribution system serving multiple restroom fixtures. 2" FD with a 2" trap and 2" waste is undersized to serve a minimum 50 gpm elevator sump discharge. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2320771 |
| Electronic Plan | Original | / | 6/15/2026 | SHANEN | SHANEN | In Current Review by SHANEN | | Electronic Plan | 2320731 |
| Elevators | Original | D | 6/12/2026 | ROBERTV | ROBERTV | See sheets: G001, A421, S121, M201, M202, E100, E401, E402, P201. . * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Elevators | 2320613 |
| CSU Waste Water | Original | D | 6/5/2026 | CSUREVIEW | CSUREVIEW | It appears that the proposed domestic wastewater service in the building is connecting into the existing grease interceptor service line. Please revise to show connection to the existing domestic wastewater service. PSD | PDosch | CSU Waste Water | 2317259 |
| CSU Water | Original | N | 6/5/2026 | CSUREVIEW | CSUREVIEW | No new water service outside of building. PSD | PDosch | CSU Water | 2317257 |
| CO Springs DRE | Original | A | 6/5/2026 | SSADLER | SSADLER | Approved for commercial interior finish. Use is compatible with the approved development plan. No exterior changes | | CO Springs DRE | 2317154 |
| Zoning/Planning | Original | / | 6/3/2026 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2316127 |
| Construction | Original | D | 6/3/2026 | BPHILLIPS | BPHILLIPS | Life safety plan, TOC. See plans for all review comments. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2316113 |
| Enumeration | Original | A | 5/15/2026 | AMY | AMY | | | Enumeration | 2307898 |
| Electronic Plan | Original | / | 5/15/2026 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 2307851 |
| | Original | / | 5/14/2026 | SYSTEM | SYSTEM | Plan Review fees paid 05/14/2026 for plan submitted 05/14/2026. Submit Date updated to now. Plan now open for review. | | | 2307660 |
| Energy | Original | / | 5/14/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2307643 |
| Floodplain | Original | N | 5/14/2026 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6430213018) | | Floodplain | 2307642 |