| Fountain Waste Water | Original | D | 7/9/2026 | FNTNSAN | FNTNSAN | | Jmoore3431 | Fountain Waste Water | 2332740 |
| Fountain Zoning | Original | D | 7/8/2026 | ZONINGF | ZONINGF | Plans marked disapproved at Applicant's request to make revisions. KM | KMartinez | Fountain Zoning | 2332200 |
| Fountain Hazmat | Original | D | 7/8/2026 | FNTNFIRE | FNTNFIRE | Disapproved Per applicant request | wkrzemien | Fountain Hazmat | 2332199 |
| Fountain Fire | Original | D | 7/8/2026 | FNTNFIRE | FNTNFIRE | Disapproved Per applicant request | wkrzemien | Fountain Fire | 2332198 |
| Fountain Water | Original | D | 7/8/2026 | FOUNTAIN | FOUNTAIN | Disapproved at applicant's request. | TMurphy | Fountain Water | 2332190 |
| Energy | Original | D | 6/22/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2324516 |
| Mechanical | Original | D | 6/22/2026 | TREVORH | TREVORH | Disapproved; Need to include Refrigeration type in the schedule and provide the Refrigeration calculation * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2324515 |
| Electrical | Original | D | 6/15/2026 | CONNERM | CONNERM | Provide fault current information (SCCR, AIC, SCA) at all of the following locations. 2. All new transfer equipment 3. All new industrial control panels 4. All new air conditioning and refrigeration equipment 5. At any of the above locations when refed
Provide demand load in amps for Panel P1
Controlled receptacles must be shown on the plan per C405.11
Provide a note on the plans indicating that the Electrical design has a maximum volt drop of 5% per C405.10.
The following general note must be included on the electrical plans: “A Final Commissioning Report shall be delivered to the building owner per section C408.2.5 of the 2021 IECC.” * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2321279 |
| Electronic Plan | Original | / | 6/15/2026 | CONNERM | CONNERM | In Current Review by CONNERM | | Electronic Plan | 2321257 |
| Plumbing | Original | D | 6/15/2026 | SHANEN | SHANEN | Compliance with 2021 IPC and CO state amendments to 2021 IPC must be stated on the plumbing plans. Show compliance with commercial plumbing plan review additional requirements for 2021 IECC. See link: https://www.pprbd.org/File/ByAlias/PlumbingReview Provide required water pipe size analysis data, see 2021 IPC appendix E. Data must include: service pressure, service size, meter size, pressure loss, available pressure, distribution size, WSFU served, developed length, etc. ST-5 is for residential use only per manufacturer. Lavatories must show compliance with 2021 IECC section C404.5.1. Waste and vent riser detail does not reflect sheet P102 piping. Show water service piping extending a minimum of 30" beyond the exterior walls. Water service entry location must correspond with the civil drawings. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2320879 |
| CSU Contract Admin. | Original | D | 6/15/2026 | CSUAPPSPRM | CSUAPPSPRM | Not in Colorado Springs Utilities' service territory. JMD | jdemello | CSU Contract Admin. | 2320850 |
| Gas/Elec. Utils | Original | D | 6/15/2026 | CSUREVIEW | CSUREVIEW | Not in Colorado Springs Utilities' gas service territory. Not in Colorado Springs Utilities' electric service territory. SSH | SHillman | Gas/Elec. Utils | 2320746 |
| Electronic Plan | Original | / | 6/15/2026 | SHANEN | SHANEN | In Current Review by SHANEN | | Electronic Plan | 2320732 |
| Elevators | Original | N | 6/12/2026 | ROBERTV | ROBERTV | No Conveyances | | Elevators | 2320695 |
| Construction | Original | D | 6/12/2026 | MATTHEWA | MATTHEWA | Code Study Form // Life Safety Plan // Occupant Loads // Complete IECC Form // Fire Separation Distances // Design Criteria // Provide PEMB plans // Fire Rated Assembly * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2320652 |
| Electronic Plan | Original | / | 6/12/2026 | MATTHEWA | MATTHEWA | In Current Review by MATTHEWA | | Electronic Plan | 2320221 |
| Enumeration | Original | D | 5/26/2026 | BRENT | BRENT | The location shown on the vicinity map on page A000 does not match the location shown on the site plan. Include a better site plan in the architectural plan pages which shows the whole parcel and the location of the proposed structures on it. Enumerations will not approve any building plans without a recorded copy of the final plat associated with this project in our records. Show the correct tax schedule number and legal description on the code study form. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2311760 |
| Electronic Plan | Original | / | 5/26/2026 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 2311710 |
| | Original | / | 5/26/2026 | SYSTEM | SYSTEM | Plan Review fees paid 05/26/2026 for plan submitted 05/22/2026. Submit Date updated to now. Plan now open for review. | | | 2311508 |
| Waste Water Div | Original | / | 5/22/2026 | SYSTEM | SYSTEM | You will need to contact Waste Water Div department for approval prior to permit. This department will not review the plan electronically. | | Waste Water Div | 2311125 |
| Water Division | Original | / | 5/22/2026 | SYSTEM | SYSTEM | You will need to contact Water Division department for approval prior to permit. This department will not review the plan electronically. | | Water Division | 2311124 |
| Energy | Original | / | 5/22/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2311123 |
| Floodplain | Original | N | 5/22/2026 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 5600000146) | | Floodplain | 2311122 |