| CO Springs DRE | Original | A | 8/14/2026 | SSADLER | SSADLER | Previous approval comments still apply | | CO Springs DRE | 2347828 |
| CSU Waste Water | Original | D | 8/13/2026 | CSUREVIEW | CSUREVIEW | Comments partially addressed. Pool must have the ability to discharge into the wastewater system and discharge rate cannot exceed 100 gpm. USP and plumbing plans still do not show how the pool drains are connected to the wastewater system. Call UDS at 719-668-8259 with questions. SSH | SHillman | CSU Waste Water | 2347352 |
| CSU Water | Original | D | 8/13/2026 | CSUREVIEW | CSUREVIEW | This will remain as a disapproval until the wastewater comments are addressed. Call UDS at 719-668-8259 with questions. SSH | SHillman | CSU Water | 2347353 |
| Zoning/Planning | Original | / | 8/13/2026 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2347081 |
| Plumbing | Original | D | 8/13/2026 | SHANEN | SHANEN | Connection for the yard hydrant must show compliance with section 608.8. Plan C191255 sheet P111 does not show compliance with this section. Any revisions to the apartment building plumbing scope will require a splice to plan C191255. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2347060 |
| Electrical | Original | A | 8/13/2026 | CONNERM | CONNERM | Encapsulation Inspection required before final. Prior to filling pool
Must comply with 680.32 NEC.
Bonding inspection is required prior to pouring concrete. If concrete is poured before bonding inspection it will need to be removed. | | Electrical | 2347056 |
| Construction | Original | D | 8/13/2026 | BPHILLIPS | BPHILLIPS | Provide required code data. Specify egress width requirements for all exit elements Specify maximum travel distance and maximum common path of travel. Clarify accessibility compliance. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2347025 |
| Enumeration | Original | A | 8/12/2026 | BRENT | BRENT | | | Enumeration | 2346683 |
| Electronic Plan | Original | / | 8/12/2026 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 2346677 |
| Submittal 2 | Original | / | 8/12/2026 | MELISSAF | MELISSAF | Submittal #2 | | Submittal 2 | 2346667 |
| EPC Health Dept | Original | N | 8/5/2026 | HEALTHDEPT | HEALTHDEPT | Not applicable. Private pool and/or spa only.
Not applicable. Earthmoving activities are < 1 acre for pool construction. MLL | mlockwood | EPC Health Dept | 2343439 |
| EPC Health Dept | Original | D | 7/28/2026 | HEALTHDEPT | HEALTHDEPT | Construction activity permit required for projects earthmoving > 1 acre. If the entire project is > 1 acre earthmoving, regardless of being submitted in phases and/or separate building permits, a construction activity permit will be required. Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/construction-land-use/construction-activity-permit/. Please submit all applications through https://myhealthdepartment.com/EPCPH. For questions, contact Environmental Health at 719-578-3199 option 3.
Private pool and/or spa only. MLL | mlockwood | EPC Health Dept | 2340076 |
| CO Springs Fire | Original | D | 7/22/2026 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | jt09ff | CO Springs Fire | 2337777 |
| CO Springs Hazmat | Original | N | 7/22/2026 | CSFIRE | CSFIRE | HAZMAT NOT PART OF SCOPE OF WORK AS POOL ROOM IS UNDER SEPARATE PERMIT | jt09ff | CO Springs Hazmat | 2337773 |
| Plumbing | Original | D | 7/16/2026 | SHANEN | SHANEN | Pool deck drains must show compliance with section 802.1.4. Pool areas shall comply with 2021 ISPSC plumbing requirements. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2335288 |
| Mechanical | Original | N | 7/9/2026 | DALEH | DALEH | | | Mechanical | 2332322 |
| City Engr | Original | A | 7/9/2026 | JDAGNILLO | JDAGNILLO | | | City Engr | 2332262 |
| EPC Health Dept | Original | D | 7/7/2026 | HEALTHDEPT | HEALTHDEPT | Construction activity permit required for projects earthmoving > 1 acre. If the entire project is > 1 acre earthmoving, regardless of being submitted in phases and/or separate building permits, a construction activity permit will be required. Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/construction-land-use/construction-activity-permit/. Please submit all applications through https://myhealthdepartment.com/EPCPH.
Water recreation plan review required for public or semi-public pool and/or spa. Information may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/public-pools-spa/. Please submit all applications through https://myhealthdepartment.com/EPCPH. For questions, contact Environmental Health at 719-578-3199 option 3. KB | KBauer | EPC Health Dept | 2331092 |
| CO Springs DRE | Original | A | 7/6/2026 | SSADLER | SSADLER | Approved for a commercial pool. Proposed plans are consistent with the dp | | CO Springs DRE | 2330901 |
| Gas/Elec. Utils | Original | A | 7/2/2026 | CSUREVIEW | CSUREVIEW | Approved development plan and utility construction drawings provided with permit set. CSU Field Engineer to determine final gas/electric meter, transformer and service line locations. Contact Field Engineering at 719-668-4985 (Gas) or 719-668-5564 (Electric) with any questions. SSH | SHillman | Gas/Elec. Utils | 2330042 |
| CSU Water | Original | D | 7/2/2026 | CSUREVIEW | CSUREVIEW | Approved Utility Service Plan (USP) must be attached to the permit set. Call UDS at 719-668-8259 with questions. SSH | SHillman | CSU Water | 2330039 |
| CSU Waste Water | Original | D | 7/2/2026 | CSUREVIEW | CSUREVIEW | Need to see how/where the pool drain ties into the wastewater system. Approved Utility Service Plan (USP) must be attached to the permit set. Call UDS at 719-668-8259 with questions. SSH | SHillman | CSU Waste Water | 2330038 |
| CSU Contract Admin. | Original | N | 7/1/2026 | CSUAPPSPRM | CSUAPPSPRM | No additional fees required for this plan set.
AMS | ASweet | CSU Contract Admin. | 2329754 |
| Zoning/Planning | Original | / | 7/1/2026 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2329587 |
| Electrical | Original | D | 7/1/2026 | CONNERM | CONNERM | Indicate compliance with 680.26 NEC.
Indicate compliance with 680.14 * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2329575 |
| Electronic Plan | Original | / | 7/1/2026 | CONNERM | CONNERM | In Current Review by CONNERM | | Electronic Plan | 2329557 |
| Construction | Original | D | 7/1/2026 | BPHILLIPS | BPHILLIPS | Life safety plan, code data, remove unnecessary sheets, show compliance with 324.7, 324.8. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2329525 |
| Electronic Plan | Original | / | 7/1/2026 | BPHILLIPS | BPHILLIPS | In Current Review by BPHILLIPS | | Electronic Plan | 2329456 |
| Enumeration | Original | D | 6/19/2026 | BRENT | BRENT | The correct address for this project is 4243 Signature Pt. Update plan pages to show the correct address. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2324333 |
| Electronic Plan | Original | / | 6/19/2026 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 2324328 |
| | Original | / | 6/19/2026 | SYSTEM | SYSTEM | Plan Review fees paid 06/19/2026 for plan submitted 06/18/2026. Submit Date updated to now. Plan now open for review. | | | 2323920 |
| Energy | Original | N | 6/18/2026 | SYSTEM | SYSTEM | Energy Department review not required under 2023 PPRBC when IECC is N/A | | Energy | 2323718 |
| Floodplain | Original | N | 6/18/2026 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6325105028) | | Floodplain | 2323717 |