| CO Springs Hazmat | Original | D | 9/21/2026 | CSFIRE | CSFIRE | Full NFPA 99 submittal must be submitted by a qualified individual ASSE 6060 is required for individuals designing medical gas and vacuum systems within the scope of the NFPA 99 Health Care Facilities Code, as mandated by the 2024 edition of NFPA 99. This means any new or existing medical gas system design, including layout, sizing, equipment selection, and installation location, must be performed by a professional holding the ASSE 6060 certification or an equivalent qualification approved by the healthcare facility's governing body. Need Specification sheets for the following: Piping Master alarm Panel Zone valve Box Head wall/wall outlets | mark.stanwood@colora | CO Springs Hazmat | 2361683 |
| CO Springs Fire | Original | A | 9/2/2026 | CSFIRE | CSFIRE | CSFD FCS: You are responsible for reviewing the comments through your ACA account. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. ALL PLAN APPROVALS SUBJECT TO FINAL INSPECTION!
HAZ-MAT REVIEW REQUIRED Based upon the information provided, a hazardous materials review is required. Your plans have been forwarded to the HazMat reviewer. | Jacob.Watson | CO Springs Fire | 2355521 |
| Mechanical | Original | A | 8/17/2026 | TCRIPPEN | TCRIPPEN | Approved | | Mechanical | 2348287 |
| CO Springs DRE | Original | A | 8/12/2026 | SSADLER | SSADLER | Commercial interior remodel approved. No changes to use, landscaping, footprint, or parking. | | CO Springs DRE | 2346475 |
| Plumbing | Original | A | 8/11/2026 | SHANEN | SHANEN | PPRBD DOES NOT REVIEW, PERMIT OR INSPECT MED GAS SYSTEMS. | | Plumbing | 2346161 |
| CSU Water | Original | N | 8/10/2026 | CSUREVIEW | CSUREVIEW | No new water service outside of building. PSD | PDosch | CSU Water | 2345595 |
| CSU Waste Water | Original | N | 8/10/2026 | CSUREVIEW | CSUREVIEW | No new wastewater service outside of building. PSD | PDosch | CSU Waste Water | 2345593 |
| Electrical | Original | D | 8/10/2026 | CONNERM | CONNERM | Show compliance with 517.13
Provide fault current info for new panels and switchgear
The following general note must be included on the electrical plans: “A Final Commissioning Report shall be delivered to the building owner per section C408.2.5 of the 2021 IECC.”
Provide a note on the plans indicating that the Electrical design has a maximum volt drop of 5% per C405.10.
Identify all electrical panels under scope of work on Power plan * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2345521 |
| Zoning/Planning | Original | / | 8/10/2026 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2345475 |
| Electronic Plan | Original | / | 8/10/2026 | CONNERM | CONNERM | In Current Review by CONNERM | | Electronic Plan | 2345434 |
| Construction | Original | D | 8/10/2026 | DOUGC | DOUGC | Rated Construction * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2345402 |
| Energy | Original | N | 8/7/2026 | SYSTEM | SYSTEM | Energy Department review not required under 2023 PPRBC when IECC is N/A | | Energy | 2344895 |
| Electronic Plan | Original | / | 8/7/2026 | DOUGC | DOUGC | In Current Review by DOUGC | | Electronic Plan | 2344854 |
| Enumeration | Original | N | 8/6/2026 | AMY | AMY | | | Enumeration | 2344078 |
| Electronic Plan | Original | / | 8/6/2026 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 2344069 |
| | Original | / | 8/5/2026 | SYSTEM | SYSTEM | Plan Review fees paid 08/05/2026 for plan submitted 08/05/2026. Submit Date updated to now. Plan now open for review. | | | 2343931 |
| Energy | Original | / | 8/5/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2343873 |
| Floodplain | Original | N | 8/5/2026 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 5307003003) | | Floodplain | 2343872 |