| Energy | Original | D | 8/14/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2348019 |
| Mechanical | Original | D | 8/14/2026 | TREVORH | TREVORH | Disapproved; The description of this plan submittal is gong to be a change of occupancy see link below for all Mechanical Requirements associated with the change of occupancy * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2348018 |
| CO Springs DRE | Original | D | 8/13/2026 | SSADLER | SSADLER | This shows that there is an occupancy/use change. On the code study form list the current business and the proposed business. | | CO Springs DRE | 2347457 |
| CSU Water | Original | N | 8/12/2026 | CSUREVIEW | CSUREVIEW | No plumbing scope of work. MLW | mlwilliams | CSU Water | 2346876 |
| CSU Waste Water | Original | N | 8/12/2026 | CSUREVIEW | CSUREVIEW | No plumbing scope of work. MLW | mlwilliams | CSU Waste Water | 2346875 |
| Zoning/Planning | Original | / | 8/12/2026 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2346817 |
| Electrical | Original | D | 8/12/2026 | CONNERM | CONNERM | All new and existing electrical devices must comply with ANSI 117.1 section 308 reach range * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2346742 |
| Plumbing | Original | D | 8/12/2026 | SHANEN | SHANEN | Change of occupancy requires compliance with 2021 IPC chapter 4. Construction review comments must be addressed to verify compliance with section 403.1. Indicated occupant load will require a drinking fountain and a service sink. Urinals must show compliance with section 405.3.5. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2346727 |
| Electronic Plan | Original | / | 8/12/2026 | CONNERM | CONNERM | In Current Review by CONNERM | | Electronic Plan | 2346721 |
| Construction | Original | D | 8/12/2026 | DOUGC | DOUGC | Change of Occupancy * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2346719 |
| Electronic Plan | Original | / | 8/11/2026 | DOUGC | DOUGC | In Current Review by DOUGC | | Electronic Plan | 2346091 |
| Enumeration | Original | D | 8/11/2026 | AMY | AMY | Permit history on this building is very dated. Please provide a floor plan showing the separation of space with all addressing in place to date on site. Permit history does not show this space was ever created. 433 Windchime Place was created. I believe this address should change to 433. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2345761 |
| Electronic Plan | Original | / | 8/11/2026 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 2345758 |
| | Original | / | 8/10/2026 | SYSTEM | SYSTEM | Plan Review fees paid 08/10/2026 for plan submitted 08/10/2026. Submit Date updated to now. Plan now open for review. | | | 2345641 |
| Energy | Original | / | 8/10/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2345612 |
| Floodplain | Original | N | 8/10/2026 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6307402278) | | Floodplain | 2345611 |