| CSU Gas | Original | A | 9/3/2026 | CSUREVIEW | CSUREVIEW | CSU Field Engineer to determine final gas meter, service line location. Contact Field Engineering at 719-668-4985 (Gas) for service line approval form or with any questions. AM | amagoon | CSU Gas | 2356344 |
| City Engr | Original | D | 9/3/2026 | JDAGNILLO | JDAGNILLO | Include a copy of the approved Development Plan in the electronic building permit set. | | City Engr | 2356212 |
| Energy | Original | D | 9/3/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2356171 |
| Mechanical | Original | D | 9/3/2026 | TREVORH | TREVORH | Disapproved;Need to see CSU gas utilities approval * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2356170 |
| CSU Contract Admin. | Original | D | 9/2/2026 | CSUAPPSPRM | CSUAPPSPRM | Requires approved Commercial Water Meter Sizing Form (CWMSF) and payment of applicable utility charges and fees. Please contact Customer Contract Administration at 719-668-8111 to discuss charges/fees and request an estimate. CWMSF available online at:
https://www.csu.org/CSUDocuments/watermetersizingforminteractive.pdf
AMS | ASweet | CSU Contract Admin. | 2355875 |
| CSU Water | Original | D | 9/2/2026 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ Refer to details B4-16 through B4-22 of the Water LESS and select an appropriate meter clearance detail to include on the plumbing plans. MLW | mlwilliams | CSU Water | 2355676 |
| CSU Waste Water | Original | D | 9/2/2026 | CSUREVIEW | CSUREVIEW | Approved Development Plan and CSU-approved Construction Drawings must be attached to the permit set. Contact Utilities Development Services at 719-668-8259 with any questions. MLW | mlwilliams | CSU Waste Water | 2355674 |
| Stormwater | Original | D | 9/2/2026 | GHUNTLEY | GHUNTLEY | Submit the approved drainage report | | Stormwater | 2355462 |
| EPC Health Dept | Original | D | 9/2/2026 | HEALTHDEPT | HEALTHDEPT | Construction activity permit required for projects earthmoving > 1 acre. If the entire project is > 1 acre earthmoving, regardless of being submitted in phases and/or separate building permits, a construction activity permit will be required. Information and application may be accessed online at https://www.elpasocountyhealth.org/licenses-permits-inspections-water-testing/construction-land-use/construction-activity-permit/. Please submit all applications through https://myhealthdepartment.com/EPCPH. For questions, contact Environmental Health at 719-578-3199 option 3. KB. | KBauer | EPC Health Dept | 2355387 |
| CSU Electric | Original | D | 9/2/2026 | CSUREVIEW | CSUREVIEW | Submit Electric Load Data Form to CSU Field Engineering. Form can be found at: https://www.csu.org/hubfs/Document-Library/ElectricLoadData.pdf?hsLang=en JAR | jreuter@csu.org | CSU Electric | 2355344 |
| Electrical | Original | D | 9/2/2026 | CONNERM | CONNERM | Remove ground from service conductors
Provide conductor size, type quantity.
Panels A and B are not shown on one-line
Comply with MERSRC CS402.7 or MLECC C410.4.2.6
Show panel and circuit number on all electrical equipment (new and relocated)
Provide fault current information (SCCR, AIC, SCA) for all new panelboards * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2355314 |
| Electronic Plan | Original | / | 9/2/2026 | CONNERM | CONNERM | In Current Review by CONNERM | | Electronic Plan | 2355274 |
| Plumbing | Original | D | 9/2/2026 | SHANEN | SHANEN | CSU approved construction drawings and utility service plan required to verify the plumbing plans correspond with the CSU approved plans for water service sizing, water entry location, building drain sizing, building drain location, grease interceptor location, etc. Clarify how water entry complies with section 305.4. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2355270 |
| CO Springs DRE | Original | D | 9/2/2026 | SSADLER | SSADLER | Upload the following documents: final approved and stamped development plan final recorded plat final approved and stamped landscaping and irrigation plans approval letter
Fees may be owed prior to building permit issuance. | | CO Springs DRE | 2355266 |
| Zoning/Planning | Original | / | 9/2/2026 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2355211 |
| Electronic Plan | Original | / | 9/2/2026 | SHANEN | SHANEN | In Current Review by SHANEN | | Electronic Plan | 2355206 |
| Construction | Original | D | 9/1/2026 | DOUGC | DOUGC | Fire Separation Distance // Soil Report // MERSRC Requirements or MLECC // AM&M * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2355196 |
| Electronic Plan | Original | / | 9/1/2026 | DOUGC | DOUGC | In Current Review by DOUGC | | Electronic Plan | 2355195 |
| Enumeration | Original | D | 8/31/2026 | AMY | AMY | 1 Plan 2 Permits required. One for the restaurant and one for the trash enclosure.
A site plan of the entire lot needs to be included in the A sheets for Enumerations purposes. We should not be marking up the Development plan. This is not lot 3A currently or proposed. Removed this from all the sheets of this plan.
Approval of this plan is pending in the Enumerations department based on Enumerations needing to review the mylar prior to plat, collection of plat fees and a copy of the final recorded plat. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2354357 |
| Electronic Plan | Original | / | 8/31/2026 | AMY | AMY | In Current Review by AMY | | Electronic Plan | 2354334 |
| | Original | / | 8/31/2026 | SYSTEM | SYSTEM | Plan Review fees paid 08/31/2026 for plan submitted 08/31/2026. Submit Date updated to now. Plan now open for review. | | | 2354325 |
| Energy | Original | / | 8/31/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2354013 |
| Floodplain | Original | N | 8/31/2026 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6226402034) | | Floodplain | 2354012 |