City Engr | Original | D | 10/30/2024 | JDAGNILLO | JDAGNILLO | Please include a copy of the revised approved non-use variance application. | | City Engr | 2079636 |
CO Springs DRE | Original | D | 10/25/2024 | DSEXTON | DSEXTON | Disapproved. The proposed retaining wall along the northern property boundary exceeds the maximum allowable height dimensional standard of four (4) feet as set forth in UDC Section 7.2.610.D.1.d. The expanded impervious area proposed above the wall was not considered to be part of the driveway after review various applicable UDC Code Sections, such as 7.4.1008.E, 7.6.301, etc. Planning staff is providing this follow-up clarification as a result of an on-site meeting on 10/25/24. (see full review) | | CO Springs DRE | 2077572 |
CO Springs DRE | Original | D | 10/24/2024 | KSCHOTT | KSCHOTT | disapproved; retaining wall does not comply with the height requirements as specified by city code within the hillside overlay. applicant is currently pursuing a nonuse variance application to increase allowable retaining wall height. (see full review) | | CO Springs DRE | 2076809 |
CO Springs DRE | Original | A | 5/31/2024 | KSCHOTT | KSCHOTT | approval for retaining walls per this hillside site and grading plan. LOD to remain on this property per plan, no walls proposed greater than 7' in height above grade. (see full review) | | CO Springs DRE | 2013945 |
CO Springs DRE | Original | / | 5/31/2024 | PDOSCH | PDOSCH | LOD, PAE, and temporary erosion control measures, Hillside Overlay Inspection 2, is compliant (see full review) | | CO Springs DRE | 2013741 |
Zoning/Planning | Original | / | 5/28/2024 | KSCHOTT | KSCHOTT | In Current Review by KSCHOTT | | Zoning/Planning | 2011375 |
Submittal 2 | Original | / | 5/28/2024 | SIERRAC | SIERRAC | Submittal #2 | | Submittal 2 | 2011337 |
CO Springs DRE | Original | D | 5/24/2024 | KSCHOTT | KSCHOTT | 1. Include hillside certification statement and sign/date on this plan (to be found on hillside site plan checklist found on City's website for Hillside Overlay) 2. Please highlight/better identify the walls that are > 7 feet tall 3. Show the side yard setback line of 10' (to ensure any walls > 7' are meeting accessory structure setback) 4. LOD boundary can't encroach into neighboring property without owner consent; adjust to be within property boundaries or provide written neighbor consent 5. LOD inspection required prior to permit approval by contacting patrick.dosch@coloradosprings.gov Informational: Please note that because this lot is within the hillside overlay; no land disturbance (including vegetation removal, excavation, grading) can occur until building permit is approved and includes an approved hillside site plan. Hillside inspections will occur throughout the permitting and construction process to ensure compliance with the hillside site plan (see full review) | | CO Springs DRE | 2011031 |
Zoning/Planning | Original | / | 5/24/2024 | KSCHOTT | KSCHOTT | In Current Review by KSCHOTT | | Zoning/Planning | 2010898 |
Stormwater | Original | A | 5/22/2024 | JLANDON | JLANDON | | | Stormwater | 2007840 |
Construction | Original | A | 5/22/2024 | SHELLEY | SHELLEY | | | Construction | 2007443 |
Electronic Plan | Original | / | 5/22/2024 | SHELLEY | SHELLEY | In Current Review by SHELLEY | | Electronic Plan | 2007441 |
Energy | Original | N | 5/20/2024 | SYSTEM | SYSTEM | Energy Department review not required under 2023 PPRBC when IECC is N/A | | Energy | 2006109 |
Floodplain | Original | N | 5/20/2024 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 6320003003) | | Floodplain | 2006108 |
Stormwater | Original | / | 5/20/2024 | SYSTEM | SYSTEM | Parcel 6320003003 is within the Hillside Overlay (HS). Stormwater Review is required. | | Stormwater | 2006107 |