CO Springs DRE | Original | D | 10/30/2024 | KSCHOTT | KSCHOTT | 1. Include newer hillside certification statement from our checklist on our website and sign/date 2. PE stamp 3. Label Limit of disturbance boundary around all disturbed areas 4. show only footprint of additions and EG/FG values at all proposed corners (limit cut/fill to < 5') 5. Show dimensions of new addition 6. Better identify existing first floor area sf , proposed covered porch or decks, proposed addition footprint only and new lot coverage calc in the legend 7. Show existing AND proposed grade on site plan 8. Identify what trees will remain and what to be removed and include vegetation assessment table from hillside site plan checklist on website. 9. Show TOW/BOW values to any proposed retaining walls, not to exceed 4' in height 10. LOD inspection required by contacting patrick.dosch@coloradosprings.gov prior to permit approval Informational: Please note that because this lot is within the hillside overlay; no land disturbance (including vegetation removal, excavation, grading) can occur until building permit is approved and includes an approved hillside site plan. Hillside inspections will occur throughout the permitting and construction process to ensure compliance with the hillside site plan (see full review) | | CO Springs DRE | 2079267 |
Mechanical | Original | A | 10/29/2024 | TREVORH | TREVORH | Approved; | | Mechanical | 2078827 |
Zoning/Planning | Original | / | 10/28/2024 | KSCHOTT | KSCHOTT | In Current Review by KSCHOTT | | Zoning/Planning | 2078333 |
Plumbing | Original | D | 10/28/2024 | SHANEN | SHANEN | 1. Please see either the "Progress Set" or the "Review Set" for required corrections. 2. The "Review Set" will become available after all department reviews are complete. 3. Electronic Plans may be re-submitted after the "Review Set" has been created. 4. After all reviews are complete, paper plans may be picked up from the same location they were submitted. | | Plumbing | 2078106 |
Stormwater | Original | D | 10/28/2024 | JLANDON | JLANDON | please include: -Legend that includes LOD, property line, existing and proposed contour lines etc. -Flow arrows -PE signature and stamp | | Stormwater | 2077989 |
Zoning/Planning | Original | / | 10/28/2024 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2077879 |
City Engr | Original | D | 10/25/2024 | JDAGNILLO | JDAGNILLO | Due to the location of this lot, Engineering Development Review has determined a full geological hazard report is required for this project and must be completed by a geotechnical engineer. It must be submitted directly to EDRD through our electronic review system called ProjectDox. Below is a link to ProjectDox and a user manual.
https://coloradosprings.gov/stormwater/planreview
EDRD's review fee will be collected by ProjectDox and if the report requires a third party review such as Colorado Geological Survey (CGS), their review fees are invoiced and paid directly to the third party review agency.
Revised application forms are available on Public Works web-page. Public Works/City Engineering Hub/New Development/Standards and References/ "References and Research Tools". https://coloradosprings.gov/public-works/page/engineering-standards-and-references | | City Engr | 2077755 |
Construction | Original | A | 10/25/2024 | SHELLEY | SHELLEY | | | Construction | 2077550 |
Energy | Original | / | 10/25/2024 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2077547 |
Electronic Plan | Original | / | 10/25/2024 | SHELLEY | SHELLEY | In Current Review by SHELLEY | | Electronic Plan | 2077543 |
Energy | Original | / | 10/23/2024 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2076575 |
Fire | Original | / | 10/23/2024 | RBD GIS | RBD GIS | Parcel 7435206012 is within the Wildland Urban Interface (WUI). Fire Department Review is required. | | Fire | 2076572 |
Stormwater | Original | / | 10/23/2024 | SYSTEM | SYSTEM | Parcel 7435206012 is within the Hillside Overlay (HS). Stormwater Review is required. | | Stormwater | 2076573 |
Floodplain | Original | N | 10/23/2024 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 7435206012) | | Floodplain | 2076574 |