Plan Details
Clear
Permits
By Address
By Permit Number
Fee Calculator
Plans
By Address
List of Plans
Links
City PlanTrac
Colorado Springs Utilities
Home
Plan #
  
Type
 
Plan
Owner
Address
2519 W PIKES PEAK AVE, COLORADO SPRINGS, CO 80904
Parcel Info
7411225031
Truss P/SF
30 (Elevation: 6,150 Feet)
Project
COMMERCIAL TO RESIDENTIAL INTERIOR REMODEL/REPAIR (
540
)
Type Of Plan
Normal
Review Type
Electronic
Fire District
COLORADO SPRINGS FIRE DIST
Submit Date
Approval Date
Location
Plan Image
View Plan Image
Download Plan Image
Map
Google Map
Yahoo Maps
Bing Maps
MapQuest
GIS Map
County Map & Data
PPRBD Directions
Required Departments: 8
By checking this box, you agree to the following:
Overtime reviews are billed at $100/hour of review time.
Requesting overtime is optional. If I don’t request it, my plan will still be reviewed in the order submitted.
Overtime reviews are dependent on staff availability, so there is no guarantee that the review will be expedited. You will only be charged overtime fees if we are able to perform those reviews. If no one is available to take that review on an overtime basis, your plan may end up being reviewed in the regular sequence.
Required Departments and Log Entries
Department
Status
Approve Overtime
Overtime
Overtime_2
BoundColumn_2
Department
Construction
D
0
C
Construction
CSU Contract Admin.
N
U
CSU Contract Admin.
Electrical
D
0
E
Electrical
Energy
D
G
Energy
Floodplain
N
W
Floodplain
Mechanical
D
0
M
Mechanical
Plumbing
D
0
P
Plumbing
CO Springs DRE
D
0
Z
CO Springs DRE
Log Entries: 11
Log Details
View Log
Log
Time Summary
Department
Splice
Status
Date
Reviewer
Reviewer
Comment
username
Department
tid
CSU Contract Admin.
Original
N
3/13/2025
CSUAPPSPRM
CSUAPPSPRM
No applicable fees due this plan set. JMD
jdemello
CSU Contract Admin.
2130695
Electrical
Original
D
3/12/2025
DANIELG
DANIELG
* Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections.
Plans cannot be re-submitted until all required departments have completed their review. *
Electrical
2130432
Energy
Original
D
3/12/2025
SYSTEM
SYSTEM
Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews
Energy
2130433
CO Springs DRE
Original
D
3/12/2025
MAMBUUL
MAMBUUL
Single family residential is a conditional use in the MX-M zone district. A conditional use permit will need to be obtained through land use review. Lot is not fully platted and may need to obtain a waiver of replat if a deed dated prior to February 13th of 1951 can not be produced.
CO Springs DRE
2130203
Plumbing
Original
D
3/12/2025
SHANEN
SHANEN
Construction review comments must be addressed.
Provide plumbing plans that comply with PPRBD requirements for residential plumbing plans. See link: https://www.pprbd.org/File/ByAlias/ResPlumbing
Remaining commercial occupancy, if any, will require compliance with section 403.1.
* Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections.
Plans cannot be re-submitted until all required departments have completed their review. *
Plumbing
2129826
Zoning/Planning
Original
/
3/11/2025
MAMBUUL
MAMBUUL
In Current Review by MAMBUUL
Zoning/Planning
2129782
Mechanical
Original
D
3/11/2025
TCRIPPEN
TCRIPPEN
DISAPPROVED: IMC 2021 SECTION 929 UNVENTED ALCOHOL FUEL-BURNING DECORATIVE APPLIANCES,SHALL BE LISTED AND LABELED IN ACCORDANCE WITH UL1370 - MANUFACTURER`S INSTALLATION AND CHAPTER 3 IMC....
HOW ARE THE UNITS BEING HEAT NOW?
* Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections.
Plans cannot be re-submitted until all required departments have completed their review. *
Mechanical
2129710
Construction
Original
D
3/11/2025
JUSTINL
JUSTINL
Preliminary review only. Plans are incomplete.
This does not appear to be entire structure based on plan R9509.
Need additional clarification:
- Is half of the building still staying commercial and this section being converted to residential?
- Would this be a live-work occupancy? This would require sprinkler systems installed throughout building per chapter 9 of the IBC.
- Is the structure being divided into 2 separate buildings? This would require a separate address.
- Need to provide full set of plans for a change of use or change of occupancy to include site plan, MEP and construction plans, IECC compliance documents as well as a full floor plan of the structure. See our website for plan requirements based on project type. May need to schedule a walk through appointment for additional questions regarding plan submittal type.
* Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections.
Plans cannot be re-submitted until all required departments have completed their review. *
Construction
2129660
Electronic Plan
Original
/
3/11/2025
JUSTINL
JUSTINL
In Current Review by JUSTINL
Electronic Plan
2129392
Energy
Original
/
3/3/2025
SYSTEM
SYSTEM
Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews
Energy
2126299
Floodplain
Original
N
3/3/2025
RBD GIS
RBD GIS
Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 7411225031)
Floodplain
2126298