CO Springs Hazmat | Original | N | 4/9/2025 | CSFIRE | CSFIRE | No inspection | michael.davis1@color | CO Springs Hazmat | 2142485 |
CO Springs Fire | Original | D | 4/9/2025 | CSFIRE | CSFIRE | You must have a ACA account in order to view your disapproval comments. You can find the link to the ACA website and a tutorial video on how to set up an account at: https://coloradosprings.gov/fire-code-resources . If you do not have an ACA account at time of CSFD review you will need to reach out to the CSFD Construction Service staff to link the review to your account. | michael.davis1@color | CO Springs Fire | 2142484 |
CO Springs DRE | Original | D | 3/27/2025 | MAMBUUL | MAMBUUL | 1. Lot is not fully platted, and a waiver of replat may be required. Recommend pre-application meeting with planner. Please vist https://coloradosprings.gov/preapp to make a pre-application appointment. 2. Need to provide scaled site plan with North directional arrow and setbacks labeled from structures to lot lines. | | CO Springs DRE | 2137088 |
City Engr | Original | D | 3/26/2025 | HVO | HVO | No geo-hazard is required. Please see comment in the site plan. | | City Engr | 2136578 |
Energy | Original | D | 3/26/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2136514 |
Electrical | Original | D | 3/26/2025 | RICHG | RICHG | Provide electrical plans see link below
https://www.pprbd.org/File/ByAlias/ResElectrical
* Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2136513 |
Mechanical | Original | D | 3/26/2025 | TREVORH | TREVORH | Disapproved; Need to see construction review comments addressed * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2136172 |
Gas/Elec. Utils | Original | A | 3/25/2025 | CSUREVIEW | CSUREVIEW | CSU Field Engineer to determine final gas/electric meter, transformer and service line locations. Contact Field Engineering at 719-668-4985 (Gas) or 719-668-5564 (Electric) with any questions. mjg | mgackle | Gas/Elec. Utils | 2136069 |
Zoning/Planning | Original | / | 3/25/2025 | MAMBUUL | MAMBUUL | In Current Review by MAMBUUL | | Zoning/Planning | 2135999 |
Construction | Original | D | 3/25/2025 | SHELLEY | SHELLEY | Too many items to list; see plans. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2135995 |
Electronic Plan | Original | / | 3/25/2025 | SHELLEY | SHELLEY | In Current Review by SHELLEY | | Electronic Plan | 2135937 |
Plumbing | Original | D | 3/24/2025 | SHANEN | SHANEN | Provide plumbing plans that comply with PPRBD requirements for residential plumbing plans. See link: https://www.pprbd.org/File/ByAlias/ResPlumbing * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Plumbing | 2135037 |
Enumeration | Original | D | 3/24/2025 | BRENT | BRENT | Include a site plan showing the entire parcel and all of the structures on it. This site plan needs to include the tax schedule number, legal description, and north arrow. Clarify if this will have a permanent cooking appliance and a sleeping area which would make this a residence as opposed to a garage conversion. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Enumeration | 2134895 |
Electronic Plan | Original | / | 3/21/2025 | BRENT | BRENT | In Current Review by BRENT | | Electronic Plan | 2134602 |
Energy | Original | / | 3/20/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2133645 |
Floodplain | Original | N | 3/20/2025 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 7411427015) | | Floodplain | 2133644 |