Finished Bin (Main) | Original | / | 5/29/2025 | | SCANNING | Location = Finished Bin (Main) by SCANNING | | Finished Bin (Main) | 2164341 |
City Engr | Original | D | 5/29/2025 | JDAGNILLO | JDAGNILLO | Engineering Development Review has determined a geological hazard waiver must be completed for this lot. It must be submitted directly to EDRD through our electronic review system called ProjectDox. Below is a link to ProjectDox and a user manual.
https://coloradosprings.gov/stormwater/planreview
Revised application forms are available on Public Works web-page. Public Works/City Engineering Hub/New Development/Standards and References/ "References and Research Tools".
plans routed to RBD https://coloradosprings.gov/public-works/page/engineering-standards-and-references | | City Engr | 2164326 |
City Engr | Original | / | 5/21/2025 | | SCANNING | Location = City Engr by SCANNING | | City Engr | 2161808 |
Plan Coordinator | Original | / | 5/21/2025 | | SSADLER | Location = Plan Coordinator by SSADLER | | Plan Coordinator | 2161440 |
CO Springs DRE | Original | D | 5/21/2025 | SSADLER | SSADLER | This lot is not fully platted. You will need to provide a recorded deed that is dated prior to February 1951 or apply for the waiver of replat. I am also showing that there is an administrative relief for lot coverage that is still in review. Once the entitlement is approved, upload the approval letter along with the approved and stamped plans. | | CO Springs DRE | 2161439 |
Zoning/Planning | Original | / | 5/16/2025 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2159837 |
Zoning/Planning | Original | / | 5/16/2025 | | SCANNING | Location = Zoning/Planning by SCANNING | | Zoning/Planning | 2159814 |
Plan Coordinator (Main) | Original | / | 5/16/2025 | | SHANEN | Location = Plan Coordinator (Main) by SHANEN | | Plan Coordinator (Main) | 2159766 |
Plumbing | Original | A | 5/16/2025 | SHANEN | SHANEN | | | Plumbing | 2159763 |
Energy | Original | D | 5/16/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2159764 |
Plumbing (Main) | Original | / | 5/16/2025 | | TCRIPPEN | Location = Plumbing (Main) by TCRIPPEN | | Plumbing (Main) | 2159677 |
Mechanical | Original | A | 5/16/2025 | TCRIPPEN | TCRIPPEN | Approved | | Mechanical | 2159676 |
Mechanical (Main) | Original | / | 5/9/2025 | | SCANNING | Location = Mechanical (Main) by SCANNING | | Mechanical (Main) | 2156869 |
Plan Coordinator (Main) | Original | / | 5/8/2025 | | RICHG | Location = Plan Coordinator (Main) by RICHG | | Plan Coordinator (Main) | 2156629 |
Electrical | Original | D | 5/8/2025 | RICHG | RICHG | Provide electrical plans. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2156628 |
Electrical (Main) | Original | / | 5/8/2025 | RICHG | RICHG | In Current Review by RICHG | | Electrical (Main) | 2156592 |
Electrical (Main) | Original | / | 5/8/2025 | RICHG | RICHG | In Current Review by RICHG | | Electrical (Main) | 2156591 |
Electrical (Main) | Original | / | 5/8/2025 | RICHG | RICHG | In Current Review by RICHG | | Electrical (Main) | 2156589 |
Electrical (Main) | Original | / | 5/8/2025 | | SCANNING | Location = Electrical (Main) by SCANNING | | Electrical (Main) | 2156001 |
Energy | Original | / | 5/7/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2155982 |
Plan Coordinator (Main) | Original | / | 5/7/2025 | | BRIANB | Location = Plan Coordinator (Main) by BRIANB | | Plan Coordinator (Main) | 2155981 |
Construction | Original | D | 5/7/2025 | BRIANB | BRIANB | 1. Fire separation distance is less than 5 feet. Provide 1hr fire-resistance exterior rated wall assembly at left and right-side elevations per table R302.1(1). Also indicate compliance with projections (soffits) and openings per table R302.1(1) 2. Missing details for dropped beam over kitchen in upper floor framing plan (no walk) * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2155980 |
Construction (Main) | Original | / | 5/7/2025 | BRIANB | BRIANB | In Current Review by BRIANB | | Construction (Main) | 2155620 |
Construction (Main) | Original | / | 4/30/2025 | | SCANNING | Location = Construction (Main) by SCANNING | | Construction (Main) | 2152495 |
Plan Coordinator (Main) | Original | / | 4/30/2025 | | BECKYA | Location = Plan Coordinator (Main) by BECKYA | | Plan Coordinator (Main) | 2152447 |
Enumeration | Original | A | 4/30/2025 | BECKYA | BECKYA | | | Enumeration | 2152446 |
Enumeration (Main) | Original | / | 4/30/2025 | BECKYA | BECKYA | In Current Review by BECKYA | | Enumeration (Main) | 2152324 |
Enumeration (Main) | Original | / | 4/30/2025 | | NELIDA | Location = Enumeration (Main) by NELIDA | | Enumeration (Main) | 2152288 |
Energy | Original | / | 4/30/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2152277 |
Floodplain | Original | N | 4/30/2025 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 7411405021) | | Floodplain | 2152276 |