| Zoning/Planning | Original | / | 12/3/2025 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2243027 |
| CO Springs DRE | Original | A | 12/3/2025 | SSADLER | SSADLER | Previous approval comments still apply | | CO Springs DRE | 2243026 |
| Energy | Original | A | 12/2/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2243002 |
| Construction | Original | A | 12/2/2025 | JUSTINL | JUSTINL | Vented crawlspace per Tim C | | Construction | 2243001 |
| Mechanical | Original | A | 12/2/2025 | TCRIPPEN | TCRIPPEN | Approved | | Mechanical | 2242996 |
| | Original | / | 12/2/2025 | SYSTEM | SYSTEM | Resubmittal Processing Fee(s) Paid | | | 2242982 |
| | Original | / | 12/2/2025 | SYSTEM | SYSTEM | Resubmittal Processing Fee Due | | | 2242980 |
| Submittal 4 | Original | / | 12/2/2025 | MELISSAF | MELISSAF | Submittal #4, Pushed plan through per Tim Crippen | | Submittal 4 | 2242979 |
| Energy | Original | D | 11/26/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2241817 |
| Construction | Original | D | 11/26/2025 | JUSTINL | JUSTINL | Upon further review, Plans changed form approved to disapproved based on information found on IECC and architectural sheets with the mechanical review department. Architectural plans show crawl space as "vented". IECC and REScheck show insulation values for conditioned crawl space. These must match. If crawl space is vented, then crawl space walls do not need to be insulated but floor insulation must be installed. If crawl space is conditioned, Update architectural sheets showing conditioned crawl space. Courtesy note: REScheck shows R19 continuous and R19 cavity insulation for a total of R38. Confirm is this is correct for a conditioned crawl space. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2241816 |
| Mechanical | Original | D | 11/26/2025 | QUINTONW | QUINTONW | Disapproved: See Heat loss cacls and Equipment Certificate * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2241811 |
| City Engr | Original | A | 11/21/2025 | JDAGNILLO | JDAGNILLO | | | City Engr | 2239690 |
| CO Springs DRE | Original | A | 11/21/2025 | SSADLER | SSADLER | Approved for proposed additions. All required entitlements are on file. | | CO Springs DRE | 2239660 |
| Zoning/Planning | Original | / | 11/19/2025 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2238414 |
| Construction | Original | A | 11/18/2025 | JUSTINL | JUSTINL | | | Construction | 2238344 |
| Electronic Plan | Original | / | 11/17/2025 | JUSTINL | JUSTINL | In Current Review by JUSTINL | | Electronic Plan | 2237157 |
| | Original | / | 11/13/2025 | SYSTEM | SYSTEM | Resubmittal Processing Fee(s) Paid | | | 2236570 |
| | Original | / | 11/13/2025 | SYSTEM | SYSTEM | Resubmittal Processing Fee Due | | | 2236389 |
| Submittal 3 | Original | / | 11/13/2025 | SIERRAC | SIERRAC | Submittal #3 | | Submittal 3 | 2236388 |
| CO Springs DRE | Original | D | 11/12/2025 | SSADLER | SSADLER | Previous comments not addressed. Once the administrative adjustment and the non use variance are approved, upload the stamped plans and the approval letters. | | CO Springs DRE | 2235814 |
| Energy | Original | D | 11/11/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2235244 |
| Mechanical | Original | D | 11/11/2025 | QUINTONW | QUINTONW | Disapproved: It appears existing equipment is being used provide a heat loss calc form for the existing house. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2235243 |
| City Engr | Original | D | 11/6/2025 | JDAGNILLO | JDAGNILLO | See previous comment - Include a copy of the approved non-use variance. Geological hazard waiver was processed and approved with the non-use variance application. (Project Dox #STM-REV25-0680) | | City Engr | 2233832 |
| Zoning/Planning | Original | / | 11/6/2025 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2233604 |
| Construction | Original | D | 11/6/2025 | SHELLEY | SHELLEY | See IECC * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2233557 |
| Submittal 2 | Original | / | 11/5/2025 | QUINTONW | QUINTONW | Submittal #2 | | Submittal 2 | 2233367 |
| City Engr | Original | D | 10/23/2025 | JDAGNILLO | JDAGNILLO | Include a copy of the approved non-use variance. Geological hazard waiver was processed and approved with the non-use variance application. (Project Dox #STM-REV25-0680) | | City Engr | 2228178 |
| CO Springs DRE | Original | D | 10/22/2025 | SSADLER | SSADLER | The non use variance and the administrative adjustment are still under review. Once they are approved, upload the approval letters and the approved stamped plans. | | CO Springs DRE | 2227407 |
| Energy | Original | D | 10/21/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2226488 |
| Mechanical | Original | D | 10/21/2025 | QUINTONW | QUINTONW | DISAPPROVED: Provide equipment certificate. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2226487 |
| Zoning/Planning | Original | / | 10/20/2025 | SSADLER | SSADLER | In Current Review by SSADLER | | Zoning/Planning | 2226037 |
| Construction | Original | D | 10/20/2025 | JUSTINL | JUSTINL | See architectural and structural sheets for review comments. Provide IECC document * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2226014 |
| Energy | Original | / | 10/20/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC Amended) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2225906 |
| Electronic Plan | Original | / | 10/20/2025 | JUSTINL | JUSTINL | In Current Review by JUSTINL | | Electronic Plan | 2225895 |
| Energy | Original | / | 10/17/2025 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC (2021 IECC) is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2225590 |
| Floodplain | Original | N | 10/17/2025 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 7411403001) | | Floodplain | 2225589 |