| WP Zoning | Original | D | 8/5/2026 | DBURGESS | DBURGESS | Pending ZDP submittal & approval. Disapproved at this time to release plan set to address PPRBD reviewers comments (AFTER WP Fire review & plan comment) | | WP Zoning | 2343571 |
| Electrical | Original | A | 8/5/2026 | CONNERM | CONNERM | | | Electrical | 2343289 |
| Energy | Original | D | 7/30/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2341097 |
| Mechanical | Original | D | 7/30/2026 | TCRIPPEN | TCRIPPEN | Disapproved:Signature required . * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2341096 |
| Plumbing | Original | A | 7/29/2026 | SHANEN | SHANEN | | | Plumbing | 2340288 |
| Electrical | Original | D | 7/28/2026 | CONNERM | CONNERM | 2021 IECC Amended no longer accepted after June 30th. Will need to submit under 2021 IECC CO MERSRC
Specify and show location of pathway for future routing of conduit from roof to electric panel
Show a 2-pole breaker space at the opposite end of the buss for Solar Ready
Verify locations of conduit and termination points serving the EV ready space.
Provide a plan note stating a minimum 2-pole, 40 amp GFCI breaker, conduit, conductor, and receptacle is provided for an EV Charger
Provide a plan note stating there will be a 2-pole breaker space for each proposed combustion appliance
Provide a plan note requiring compliance with 2021 ECC R402.4.6 limiting air leakage through electrical and communication outlet boxes installed in the building thermal envelope * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2340269 |
| Electronic Plan | Original | / | 7/28/2026 | CONNERM | CONNERM | In Current Review by CONNERM | | Electronic Plan | 2340264 |
| Construction | Original | D | 7/28/2026 | MATTHEWA | MATTHEWA | Code references // Provide rated soffit information, fire separation distance less than 5' from property line // Multiple structural elements require stamped design from licensed design professional * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2340261 |
| Electronic Plan | Original | / | 7/28/2026 | MATTHEWA | MATTHEWA | In Current Review by MATTHEWA | | Electronic Plan | 2340210 |
| WP Floodplain | Original | N | 7/14/2026 | DBURGESS | DBURGESS | Verified not in a floodplain | | WP Floodplain | 2333961 |
| WP Enumeration | Original | A | 7/14/2026 | DBURGESS | DBURGESS | Address, Parcel Number & Tax Number matches Teller County Assessor's published online data. Revised the owner in the plan record to match the Teller County Assessor's published online data. | | WP Enumeration | 2333959 |
| | Original | / | 7/13/2026 | SYSTEM | SYSTEM | Plan Review fees paid 07/13/2026 for plan submitted 07/13/2026. Submit Date updated to now. Plan now open for review. | | | 2333601 |
| Energy | Original | / | 7/13/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2333598 |