| Energy | Original | D | 9/4/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2356538 |
| Mechanical | Original | D | 9/4/2026 | QUINTONW | QUINTONW | Disapproved: Update the Insulation values on the heat calculations for the addition to ensure they match the IECC provided. Provide the manufacture specifications for the grill. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Mechanical | 2356537 |
| EPC Health Dept | Original | N | 9/4/2026 | HEALTHDEPT | HEALTHDEPT | Current 2023 OWTS approval is for a 4-bedroom home. The assessor indicates current home is 3 bedroom; therefore, the scope of work does not impact the current OWTS approval on file. - TO | heasepticinfo | EPC Health Dept | 2356531 |
| County Zoning | Original | A | 9/2/2026 | DSDHILLS | DSDHILLS | Addition Approved (see full review) | | County Zoning | 2355840 |
| Electronic Plan | Original | / | 9/2/2026 | QUINTONW | QUINTONW | In Current Review by QUINTONW | | Electronic Plan | 2355646 |
| Electrical | Original | D | 9/2/2026 | CONNERM | CONNERM | Show location of conduit and termination points serving the EV ready space
Show an EV ready space noted in the garage
Provide a plan note stating a minimum 2-pole, 40 amp GFCI breaker, conduit, conductor, and receptacle is provided for an EV Charger
Provide a plan note stating there will be a 2-pole breaker space for each proposed combustion appliance
Provide a plan note stating compliance with 2021 IECC R402.4.6 limiting air leakage through electrical and communication outlet boxes installed in the building thermal envelope
Remove amendments and fully comply with IECC R404.2 * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Electrical | 2355615 |
| Zoning/Planning | Original | / | 9/2/2026 | DSDHILLS | DSDHILLS | In Current Review by DSDHILLS | | Zoning/Planning | 2355614 |
| Electronic Plan | Original | / | 9/2/2026 | CONNERM | CONNERM | In Current Review by CONNERM | | Electronic Plan | 2355605 |
| Plumbing | Original | A | 9/2/2026 | SHANEN | SHANEN | | | Plumbing | 2355587 |
| Construction | Original | D | 9/2/2026 | MATTHEWA | MATTHEWA | Roof framing at front porch // Roof truss callouts // Truss connections in garage // Provide manufacturer''s specifications for clearance to combustibles for gas appliances at front and rear decks. * Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections. Plans cannot be re-submitted until all required departments have completed their review. * | | Construction | 2355582 |
| Electronic Plan | Original | / | 9/2/2026 | MATTHEWA | MATTHEWA | In Current Review by MATTHEWA | | Electronic Plan | 2355467 |
| | Original | / | 8/31/2026 | SYSTEM | SYSTEM | Plan Review fees paid 08/31/2026 for plan submitted 08/31/2026. Submit Date updated to now. Plan now open for review. | | | 2354316 |
| Energy | Original | / | 8/31/2026 | SYSTEM | SYSTEM | Energy Department review for 2023 PPRBC is based on status of Construction, Electrical, Mechanical and Plumbing reviews | | Energy | 2354313 |
| Health Dept. | Original | / | 8/31/2026 | SYSTEM | SYSTEM | Health dept review is required for a residential addition, basement finish, or interior remodel for properties that have a septic system. Contact HEASepticinfo@elpasoco.com for additional information. | | Health Dept. | 2354311 |
| Floodplain | Original | N | 8/31/2026 | RBD GIS | RBD GIS | Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 5205101022) | | Floodplain | 2354312 |