35 MALLORY RD, COLORADO SPRINGS, CO 80906
Parcel Info
7512406008
Truss P/SF
30 (Elevation: 6,454 Feet)
Project
Residential Pool (
434
)
Type Of Plan
Normal
Review Type
Electronic
Fire District
COLORADO SPRINGS FIRE DIST
Submit Date
Approval Date
Location
Plan Image
View Plan Image
Download Plan Image
Map
Google Map
Yahoo Maps
Bing Maps
MapQuest
GIS Map
County Map & Data
PPRBD Directions
Required Departments: 9
By checking this box, you agree to the following:
Overtime reviews are billed at $100/hour of review time.
Requesting overtime is optional. If I don’t request it, my plan will still be reviewed in the order submitted.
Overtime reviews are dependent on staff availability, so there is no guarantee that the review will be expedited. You will only be charged overtime fees if we are able to perform those reviews. If no one is available to take that review on an overtime basis, your plan may end up being reviewed in the regular sequence.
Required Departments and Log Entries
Department
Status
Approve Overtime
Overtime
Overtime_2
BoundColumn_2
Department
City Engr
D
0
S
City Engr
Construction
D
0
C
Construction
Electrical
A
0
E
Electrical
Energy
N
G
Energy
Floodplain
N
W
Floodplain
Mechanical
D
0
M
Mechanical
Plumbing
N
0
P
Plumbing
Stormwater
D
0
Q
Stormwater
CO Springs DRE
D
0
Z
CO Springs DRE
Log Entries: 15
Log Details
View Log
Log
Time Summary
Department
Splice
Status
Date
Reviewer
Reviewer
Comment
username
Department
tid
Stormwater
Original
D
11/19/2026
JLANDON
JLANDON
include the following items on the hillside development plan.
Hillside plan stormwater checklist:
1. LOD
2. Existing and proposed contour lines (they should have labels)
3. Legend
4. Stockpile - it must be inside the LOD
5. Flow arrows
6. PE signature and stamp
7. Overall grading - will water drain appropriately and not pool badly (e.g. against a building)?
Stormwater
2384475
Electronic Plan
Original
/
11/19/2026
DALEH
DALEH
In Current Review by DALEH
Electronic Plan
2384126
CO Springs DRE
Original
D
11/19/2026
SSADLER
SSADLER
Submit the required hillside site plan. Show the top of wall and bottom of wall elevations. Show the limit of disturbance. Show the stockpile location.
CO Springs DRE
2384105
Mechanical
Original
D
11/18/2026
DALEH
DALEH
Indicate if pool heater will be Electric, Gas ,Propane etc......
* Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections.
Plans cannot be re-submitted until all required departments have completed their review. *
Mechanical
2383973
City Engr
Original
D
11/17/2026
DSOSA
DSOSA
Engineering Development Review has determined geological hazards exist in this area and requires a Geologic Hazard Report. Please submit the report to EDR through our electronic review system called ProjectDox. Below is a link to ProjectDox and a user manual.
https://coloradosprings.gov/stormwater/planreview
Application forms are available on the Public Works webpage:
Public Works>City Engineering Hub>Engineering Standards and References>References and Research Tools
https://coloradosprings.gov/public-works/page/engineering-standards-and-references
Once approved, please upload the approved file with the building permit submittal.
City Engr
2383070
Electrical
Original
A
11/17/2026
CONNERM
CONNERM
Encapsulation Inspection required before final. Prior to filling pool
Bonding inspection is required prior to pouring concrete. If concrete is poured before bonding inspection it will need to be removed.
Must comply with 680.32 NEC.
Must comply with 680.14
Electrical
2383068
Electronic Plan
Original
/
11/17/2026
CONNERM
CONNERM
In Current Review by CONNERM
Electronic Plan
2383055
Stormwater
Original
/
11/17/2026
GHUNTLEY
GHUNTLEY
N/A - No stormwater scope of work.
Stormwater
2383010
Zoning/Planning
Original
/
11/16/2026
SSADLER
SSADLER
In Current Review by SSADLER
Zoning/Planning
2382809
Plumbing
Original
N
11/16/2026
SHANEN
SHANEN
Plumbing
2382808
Construction
Original
D
11/16/2026
DOUGC
DOUGC
Fence // Equipment room // Energy
* Please see either the "Progress Set" or the "Review Set" for complete list of this department's corrections.
Plans cannot be re-submitted until all required departments have completed their review. *
Construction
2382757
Electronic Plan
Original
/
11/16/2026
DOUGC
DOUGC
In Current Review by DOUGC
Electronic Plan
2382718
Energy
Original
N
11/6/2026
SYSTEM
SYSTEM
Energy Department review not required under 2023 PPRBC when IECC is N/A
Energy
2379556
Stormwater
Original
/
11/6/2026
SYSTEM
SYSTEM
Parcel 7512406008 is within the Hillside Overlay (HS). Stormwater Review is required.
Stormwater
2379554
Floodplain
Original
N
11/6/2026
RBD GIS
RBD GIS
Autogenerated Review: Outside 100 Year Floodplain. (Parcel: 7512406008)
Floodplain
2379555