CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/02/2024 | PERFORMED EXTERNAL INSPECTION ON ESCALATOR -- / NO VISIBLE CODE ISSUES (Receipt #2020932) | DUSTINS | DUSTINS | | H02 | C | 7957692 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 11/28/2023 | WITNESSED AT HO1 (Receipt #2011181) | BENH | BENH | | H01 | C | 7928425 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H07 | C | 11/28/2023 | WITNESSED ANNUAL TEST W/ ELEVATOR TECHNICIANS -- NOTE: ALL MAINTENANCE AND REPAIRS TO BE LOGGED IN M.C.P. AND HANDRAIL DRIVE CHAIN TO BE EXAMINED EVERY 6 MONTHS AND LOGGED IN M.C.P. | BENH | BENH | | H07 | C | 7928395 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 10/19/2023 | NOTIFIED BY ELEVATOR TECHNICIANS REPAIRS HAVE BEEN STARTED AND IS OK TO REMOVE METER SEAL. WILL NEED FULL ANNUAL WITNESS TEST BEFORE UNIT CAN BE PLACED INTO SERVICE. | ROBERTV | ROBERTV | | HE16 | C | 7892863 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H05 | C | 07/24/2023 | ESCALATOR DOWN FOR REPAIRS AT TIME OF INSPECTION / ANNUAL WITNESS TESTING TO BE PERFORMED BEFORE ESCALATOR CAN BE RETURNED TO NORMAL SERVICE / RBD NOTE: CREATE H01 WHEN H07 IS PERFORMED | DUSTINS | DUSTINS | | H05 | C | 7805672 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/13/2023 | MONTGOMERY ESCALATOR - UNIT WAS SHUT DOWN AND DISCONNECT TAGGED DUE TO THE FOLLOWING: LOWER LANDING PLATE AND COMB PLATE DO NOT MESH WITH STEP TREADWAYS. SEVERAL SEVERELY CHIPPED STEP TREADWAYS NEED REPLACED. STEP TO STEP GAP IS IN EXCESS OF 1/4" IN THE RISE (STEP TREADWAYS AND RISERS DO NOT MESH). SOURCE OF OIL ON STEPS NEEDS TO BE ADDRESSED. HANDRAIL DRIVE CHAIN AND DRIVING COMPONENTS ARE POPPING LOUDLY. LOWER INNER DECK TRANSITION PANELS NEED TO BE SECURED COMPLETELY......... UNIT MAY NOT RETURN TO SERVICE UNTIL ALL ITEMS ARE ADDRESSED. | ROBERTV | ROBERTV | | H02 | C | 7634755 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H07 | C | 11/03/2022 | WITNESSED ESCALATOR SAFETY AND STEP INDEX TESTING W/ ELEVATOR TECHNICIANS TO RETURN ESCALATOR BACK TO SERVICE AFTER REPAIRS WERE MADE -- / NOTE: HANDRAIL DRIVE CHAINS EXAMINATIONS AND/OR ADJUSTMENTS SHALL TAKE PLACE IN INTERVALS NO MORE THAN 6 MONTHS FROM HEREON AND SHALL BE DOCUMENTED IN THE ESCALATOR MAINTENANCE AND REPAIR RECORDS ONSITE. FAILURE TO PROVIDE DOCUMENTATION WILL RESULT IN THE ESCALATOR BEING REMOVED FROM SERVICE. (BRAKE TORQUE MINIMUM 45 FT/LBS -- ACTUAL 70 FT/LBS) | DUSTINS | DUSTINS | | H07 | C | 7571176 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/26/2022 | ESCALATOR IS SHUTDOWN PENDING REPAIRS. WILL NEED WITNESSED STEP INDEX AND SAFETY INSPECTION BEFORE UNIT CAN BE RETURNED TO SERVICE. (HOLD PERMIT TO OPERATE) (Receipt #1886327) | ROBERTV | ROBERTV | | H01 | C | 7460784 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/21/2022 | MONTGOMERY ESCALATOR - STILL OUT OF SERVICE PENDING REPAIRS NEEDED. NEED WITNESS TESTING COMPLETED AFTER REPAIRS BEFORE UNIT CAN BE RETURNED TO SERVICE. | ROBERTV | ROBERTV | | H02 | C | 7246010 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/26/2021 | MONTGOMERY ESCALATOR - STILL OUT OF SERVICE PENDING REPAIRS NEEDED FROM ANNUAL INSPECTION AND TESTING. NEED TESTING COMPLETED AFTER REPAIRS BEFORE UNIT CAN BE RETURNED TO SERVICE. (Receipt #1793317) | ROBERTV | ROBERTV | | H01 | C | 7049581 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/26/2021 | MONTGOMERY ESCALATOR - STILL OUT OF SERVICE PENDING REPAIRS NEEDED FROM ANNUAL INSPECTION AND TESTING | ROBERTV | ROBERTV | | H02 | C | 6848451 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/22/2020 | MONTGOMERY ESCALATOR - STILL OUT OF SERVICE PENDING REPAIRS NEEDED FROM ANNUAL INSPECTION AND TESTING (Receipt #1698089) | ROBERTV | ROBERTV | | H01 | C | 6646616 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 04/08/2020 | WITNESSED ANNUAL ESCALATOR SAFETY AND STEP INDEX INSPECTION W/ OTIS - MAIN DRIVE RING GEAR AND PINION GEAR ARE WORN DUE TO LACK OF LUBRICATION. ELECTRICAL CONDUIT TO DRIVE MOTOR NEEDS REPLACED DUE TO LOOSE HANDRAIL DRIVE CHAIN WEARING INTO IT. UPPER RIGHT END SKIRT BRUSH END CAP MISSING............. (NOTE: BRAKE TORQUE MINIMUM 45 FT/LBS - ACTUAL 109 FT / LBS) | ROBERTV | ROBERTV | | HE16 | C | 6534564 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/13/2020 | MONTGOMERY ESCALATOR - OUT OF SERVICE AT TIME OF INSPECTION. WITNESSED ANNUAL SAFETY TESTING DUE BY 03/31/2020 | ROBERTV | ROBERTV | | H02 | C | 6450792 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/17/2019 | MONTGOMERY ESCALATOR - OUT OF SERVICE AT TIME OF INSPECTION. WITNESSED ANNUAL SAFETY TESTING DUE BY 11/30/2019 (Receipt #1614812) | ROBERTV | ROBERTV | | H01 | C | 6266424 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/31/2019 | MONTGOMERY ESCALATOR - KNIFE EDGED STEPS NEED TO BE REPLACED WITHIN 30 DAYS. LOWER END CENTER DECK BARRICADE NEED TO BE INSTALLED WITHIN 30 DAYS. GEARBOX OIL IS ALL OVER STEPS AGAIN, THIS NEED TO BE DIAGNOSED......... HANDRAIL INLETS ARE SCHEDULED TO BE REPLACED. ALL OTHER INTERNAL ITEMS ADDRESSED PER OTIS. | ROBERTV | ROBERTV | | H02 | C | 6093185 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 11/05/2018 | MONTGOMERY ESCALATOR - WITNESSED ANNUAL STEP INDEX AND SAFETY INSPECTION W/ OTIS. ALL HANDRAIL INLET DEVICES NEED TO BE REPLACED AND ARE PRESENTLY BEING MANUFACTURED. HANDRAIL DRIVE CHAIN IS LOOSE AND NEEDS ADJUSTED. KNIFE EDGE STEP TREADWAYS NEED TO BE REPLACED. SECURE LOWER END CENTER DECK BARRICADE. CLEAN OIL FROM STEP RISERS AND MONITOR AS GEARBOX MAY BE LEAKING. MACHINE PITS NEED TO BE CLEANED......... 30 DAY FOLLOW UP SCHEDULED. (NOTE: BRAKE TORQUE 75 FT/LBS -------- 45-55 REQUIRED) | ROBERTV | ROBERTV | | HE16 | C | 6016069 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/10/2018 | MONTGOMERY ESCALATOR -- UNIT HAS YET TO RECEIVE NEW HANDRAIL INLET DEVICES AS NOTED SINCE 10/2016. THERE HAS BEEN NO INDICATION TO DATE AS TO WHEN THESE WILL BE REPLACED FROM MANAGEMENT OR ELEVATOR SERVICE COMPANY. THE UNIT WILL BE REMOVED FROM SERVICE AGAIN 8/1/2018 IF HANDRAIL INLETS HAVE NOT BEEN REPLACED.......... ALSO, NEED TO SECURE LOWER END CENTER DECK BARRICADE, NEED REPAIR/ADJUSTMENTS/CALLBACK LOGS IN ESCALATOR MAINTENANCE CONTROL PROGRAM. | ROBERTV | ROBERTV | | H01 | C | 5897506 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/08/2018 | ITEMS AS LISTED ON INSPECTION REPORT DATED 10/2017 AND PRIOR: ------ ALL HANDRAIL ENTRY DEVICES ARE EXCESSIVELY WORN AND NEED REPLACED, UNKNOWN IF ESCALATOR HAVE BEEN CLEANED........ NOTE: LEFT SIDE OF STEP TREADWAYS HAVE A COUPLE KNIFE EDGES THAT WILL NEED TO BE ADDRESSED AT SOME POINT, WILL CONTINUE TO MONITOR. | ROBERTV | ROBERTV | | H02 | C | 5731061 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 10/17/2017 | WITNESSED ANNUAL SAFETY INSPECTION AND STEP INDEX TESTING WITH OTIS - ALL HANDRAIL ENTRY DEVICES ARE EXCESSIVELY WORN AND NEED REPLACED, ESCALATOR PITS NEED CLEANED........ NOTE: LEFT SIDE OF STEP TREADWAYS HAVE A COUPLE KNIFE EDGES THAT WILL NEED TO BE ADDRESSED AT SOME POINT, WILL CONTINUE TO MONITOR. | ROBERTV | ROBERTV | | HE16 | C | 5657890 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/07/2017 | MONTGOMERY W/ OTIS SERVICE -- HANDRAIL ENTRY DEVICES NEED TO BE REPLACED (3RD NOTICE), MISSING CENTER DECK BARRICADE AT BOTTOM NEEDS INSTALLED (2ND NOTICE), NEED ESCALATOR MAINTENANCE CONTROL PROGRAM ONSITE (2ND NOTICE). THESE ITEMS NEED TO BE ADDRESSED BEFORE ANNUAL TESTING 10/2017 OR THE UNIT WILL NOT RETURN TO SERVICE. (Receipt #1437221) | ROBERTV | ROBERTV | | H01 | C | 5556760 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/19/2017 | MONTGOMERY - HANDRAIL ENTRY DEVICES STILL NEED TO BE REPLACED, RE-SECURE LOWER CENTER DECK BARRICADE, NEED ESCALATOR MAINTENANCE CONTROL PROGRAM ONSITE. | ROBERTV | ROBERTV | | H02 | C | 5392531 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 10/28/2016 | PERFORMED ANNUAL STEP INDEX AND SAFETY TESTING W/ OTIS -- HANDRAIL ENTRY DEVICES NEED REPLACED ON ALL 4 CORNERS - (EXISTING PARTS AND PIECES ARE BEYOND REPAIR). LOWER STEP UPTHRUST SWITCHES NEED ADJUSTED AND SECURED TO WORK PROPERLY. | ROBERTV | ROBERTV | | HE16 | C | 5330272 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/15/2016 | CORRECTIONS MADE (Receipt #1342025) | ERIC | ERIC | | H01 | C | 5245789 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 02/26/2016 | WITNESSED ANNUAL SAFETY AND STEP INDEXING INSPECTION W/ OTIS - DEMARCATION LIGHTS NOT WORKING | ROBERTV | ROBERTV | | HE16 | C | 5145382 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/11/2016 | DRIVE MOTOR IS BAD -- NO INSPECTION PERFORMED. IMMEDIATELY AFTER REPAIRS ARE COMPLETED, AN ANNUAL STEP AND SAFETY TEST IS REQUIRED. NEED MAINTENANCE CONTROL PROGRAM DOCUMENTS ONSITE NEXT INSPECTION | ROBERTV | ROBERTV | | H02 | C | 5113188 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 11/16/2015 | DRIVE MOTOR IS BAD -- NO INSPECTION PERFORMED. IMMEDIATELY AFTER REPAIRS ARE COMPLETED, AN ANNUAL STEP AND SAFETY TEST IS REQUIRED. | ROBERTV | ROBERTV | | HE16 | C | 5079887 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/06/2015 | NEED ANNUAL SAFETY INSPECTION AND INDEX TESTING FOR 2015, HANDRAIL DAMAGED AND MUST BE REPLACED, STILL NEED CENTER DECK BARRICADE AT BOTTOM END (Receipt #1272524) | ERIC | ERIC | | H01 | C | 4987333 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/08/2015 | MKE, OTIS SERVICE. LEFT HANDRAIL NEEDS REPLACED, EMERGENCY STOP SWITCH ALARM BELL NOT WORKING, BOTTOM KEY SWITCH NOT WORKING, NEED CLEAN DOWN AND COMPLETE STEP INSPECTION | ERIC | ERIC | | H02 | C | 4882392 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 12/31/2014 | WITNESSED ANNUAL SAFETY INSPECTION AND INDEX TESTING. LEFT HANDRAIL NEEDS REPLACED, EMERGENCY STOP SWITCH ALARM BELL NOT WORKING, BOTTOM KEY SWITCH NOT WORKING, NEED CLEAN DOWN AND COMPLETE STEP INSPECTION | ERIC | ERIC | | HE16 | C | 4879242 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/01/2014 | MKE. OTIS SERVICE. EXCESSIVELY WORN STEP TREADS, NEED ANNUAL SAFETY INSPECTION AND INDEX TESTING FOR 2014 (Receipt #1204918) | ERIC | ERIC | | H01 | C | 4769857 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/16/2014 | MKE. OTIS SERVICE. NEED TO PROPERLY BARRICADE AREA BETWEEN ESCALATORS AT BOTTOM, REPLACE EXCESSIVELY WORN STEP TREADS | ERIC | ERIC | | H02 | C | 4673539 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/10/2013 | MKE. OTIS SERVICE, NEED TO PROPERLY BARRICADE AREA BETWEEN ESCALATORS (Receipt #1141042) | ERIC | ERIC | | H01 | C | 4560621 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 04/26/2013 | INDEX TESTING COMPLETE | ERIC | ERIC | | HE16 | C | 4513255 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 04/18/2013 | ANNUAL INSPECTION-NEED CLEAN DOWN, UPPER RIGHT SKIRT SWITCH NEEDS TO BE ADJUSTED, STOP SWITCH ALARM BELL NOT FUNCTIONING, REPAIR BOTTOM HANDRAIL INLETS, UPTHRUST SWITCHES NOT WORKING, SEVERAL CHIPPED STEP TREADS, SEVERAL SECTIONS OF STEP CHAINS STRETCHED BEYOND ALLOWABLE TOLERANCE, INSTALL DECK BARRICADES IN PROPER LOCATIONS | ERIC | ERIC | | HE16 | C | 4510843 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/22/2013 | MKE. OTIS SERVICE, INSTALL DECK BARRICADES IN PROPER LOCATIONS, MANY EXCESSIVELY WORN STEP TREADS, NEED ANNUAL WITNESSED INSPECTION AND INDEX TESTING | ERIC | ERIC | | H02 | C | 4458391 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/02/2012 | MKE. OTIS SERVICE, NEED LOWER DECK BARRICADES, CHIPPED AND EXCESSIVELY WORN STEP TREADS, GAPS IN GLASS PANELS EXCEED 1/4", REPLACE DAMAGED GLASS PANELS, NEED INDEX TESTING AND ANNUAL INSPECTION FOR 2012 (Receipt #1056558) | ERIC | ERIC | | H01 | C | 4335327 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/09/2012 | MKE. OTIS SERVICE. NEED DECK BARRICADES INSTALLED, EXCESSIVELY WORN STEP TREADS, BROKEN COMB TEETH, GAPS IN GLASS PANELS EXCEED 1/4" | ERIC | ERIC | | H02 | C | 4258355 |
COYOTE MANAGEMENT LP | HE16 | C | 08/22/2011 | ANNUAL INSPECTION AND INDEX TESTING COMPLETE | ERIC | ERIC | | HE16 | C | 4196547 |
COYOTE MANAGEMENT LP | H01 | C | 07/13/2011 | MKE. OTIS SERVICE. EXCESSIVELY WORN STEP TREADS, DEMARCATION LIGHTS OUT, NEED TO INSTALL LOWER DECK BARRICADES, (Receipt #986133) | ERIC | ERIC | | H01 | C | 4177195 |
GENERAL GROWTH | H02 | C | 01/10/2011 | MKE. NEED ANNUAL INDEX TESTING AND INSPECTION, BROKEN COMB TOOTH, BROKEN AND WORN STEP TREADS, GAPS BETWEEN GLASS BALUSTRADE PANELS NEED ADJUSTMENT | ERIC | ERIC | | H02 | C | 4096689 |
GENERAL GROWTH | H01 | C | 07/16/2010 | NEED ANNUAL INSPECTION AND INDEX TESTING (Receipt #920619) | ERIC | ERIC | | H01 | C | 4010850 |
GENERAL GROWTH | H02 | C | 01/07/2010 | MONTGOMERY | ERIC | ERIC | | H02 | C | 3930009 |
GENERAL GROWTH | HE16 | C | 12/16/2009 | WITNESSED INDEX TESTING | ERIC | ERIC | | HE16 | C | 3923567 |
GENERAL GROWTH | H01 | C | 07/15/2009 | MONTGOMERY, DEMARCATION LIGHTS OUT AT BOTTOM LANDING. NEED ANNUAL PERFORMANCE INDEX TEST (Receipt #867323) | ERIC | ERIC | | H01 | C | 3858769 |
GENERAL GROWTH | HE16 | C | 01/27/2009 | WITNESSED ANNUAL TEAR DOWN AND SAFETY TESTS | ERIC | ERIC | | HE16 | C | 3795431 |
GENERAL GROWTH | H02 | C | 01/27/2009 | MONTGOMERY. 2 BROKEN STEP TREADS | ERIC | ERIC | | H02 | C | 3795429 |
GENERAL GROWTH | H01 | C | 07/31/2008 | MONTGOMERY --- TOOTH MISSING AT BOTTOM LANDING COMB PLATE --- BRUSHES INSTALLED (Receipt #819273) | LES | LES | | H01 | C | 3717772 |
GENERAL GROWTH | H02 | C | 01/29/2008 | MONTGOMERY--UNIT WAS NOT IN OPERATION AT THE TIME OF INSPECTION | JOHNW | JOHNW | | H02 | C | 430771 |
GENERAL GROWTH | H01 | C | 08/28/2007 | MONTGOMERY--HANDRAIL SLIPPING --EXCESSIVE GAP ON SEVERAL TREADS--COMB PLATE LOOSE AT THE BOTTOM LANDING | JOHNW | JOHNW | | H01 | C | 430762 |
GENERAL GROWTH | H02 | C | 01/31/2007 | MONTGOMERY--HAND RAIL DAMAGED --LOWER LANDING MISSING BARRICADES--COMB PLATE AT TOP BROKEN--INDEX TEST NOT PREFORMED | JOHNW | JOHNW | | H02 | C | 430754 |
GENERAL GROWTH | H01 | C | 07/31/2006 | MONTGOMERY---BROKEN COMB | JOHNW | JOHNW | | H01 | C | 430746 |
GENERAL GROWTH | H02 | C | 01/20/2006 | #CE62010--MONTGOMERY--DEMARCATION LIGHT AT TOP OUT | JOHNW | JOHNW | | H02 | C | 430739 |
GENERAL GROWTH | H01 | C | 07/25/2005 | MONTGOMERY--DEMARCATION LIGHTS AT TOP AND BOTTOM ARE OUT | JOHNW | JOHNW | | H01 | C | 430731 |
GENERAL GROWTH | H02 | C | 01/31/2005 | #CE62010 / MONTGOMERY--8 BROKEN STEP TREDS--EMERGENCY ALARM ON STOP SWITCH INOP-- BARRICADES AT THE BOTTOM? | JOHNW | JOHNW | | H02 | C | 430723 |
GENERAL GROWTH | H01 | C | 07/07/2004 | 6 BROKEN STEP TREDS | LES | LES | | H01 | C | 430716 |
GENERAL GROWTH | H02 | C | 01/26/2004 | MONTGOMERY --- 4 BROKEN STEP TREDS | LES | LES | | H02 | C | 430707 |
GENERAL GROWTH | H01 | C | 07/16/2003 | 3 TEETH MISSING AT THE BOTTOM LANDING --- REPLACE MISSING SCREWS ON SKIRTING | LES | LES | | H01 | C | 430700 |
GENERAL GROWTH | H02 | C | 01/23/2003 | 3 TEETH MISSING AT BOTTOM LANDING | LES | LES | | H02 | C | 430693 |
GENERAL GROWTH | H01 | C | 07/19/2002 | | LES | LES | | H01 | C | 430687 |
GENERAL GROWTH | H02 | C | 01/23/2002 | ALARM INOP --- CHECK STEP TO SKIRT CLEARENCES --- REPAIR STEP DEMARCATION LIGHTS --- REPLACE MISSING SCREWS ON SKIRTING | LES | LES | | H02 | C | 430680 |
GENERAL GROWTH | H01 | C | 07/30/2001 | TOOTH MISSING BOTTOM LANDING | LES | LES | | H01 | C | 430671 |
GENERAL GROWTH | H02 | C | 01/26/2001 | CENTER COURT DOWN | LES | LES | | H02 | C | 430664 |
GENERAL GROWTH | H01 | C | 07/27/2000 | LOCATION SHOULD BE CENTER COURT | LES | LES | | H01 | C | 430656 |
GENERAL GROWTH | H02 | C | 01/28/2000 | | TOM | TOM | | H02 | C | 430648 |
GENERAL GROWTH | H01 | C | 07/13/1999 | | RUSS | RUSS | | H01 | C | 430490 |
GENERAL GROWTH | H02 | C | 01/20/1999 | | RUSS | RUSS | | H02 | C | 430481 |
GENERAL GROWTH | H01 | C | 07/23/1998 | | RUSS | RUSS | | H01 | C | 430473 |
GENERAL GROWTH | H02 | C | 01/28/1998 | | RUSS | RUSS | | H02 | C | 430465 |
GENERAL GROWTH | H01 | C | 07/02/1997 | | RUSS | RUSS | | H01 | C | 430639 |
GENERAL GROWTH | H02 | C | 01/11/1997 | | RUSS | RUSS | | H02 | C | 430631 |
GENERAL GROWTH | H01 | C | 07/02/1996 | | RUSS | RUSS | | H01 | C | 430623 |
GENERAL GROWTH | H02 | C | 01/08/1996 | | RUSS | RUSS | | H02 | C | 430615 |
GENERAL GROWTH | H01 | C | 07/20/1995 | | RUSS | RUSS | | H01 | C | 430608 |
GENERAL GROWTH | H02 | C | 01/19/1995 | | RUSS | RUSS | | H02 | C | 430600 |
GENERAL GROWTH | H01 | C | 07/08/1994 | | RUSS | RUSS | | H01 | C | 430592 |
GENERAL GROWTH | H02 | C | 01/24/1994 | | RUSS | RUSS | | H02 | C | 430584 |
GENERAL GROWTH | H01 | C | 07/06/1993 | | RUSS | RUSS | | H01 | C | 430576 |
GENERAL GROWTH | H02 | C | 01/15/1993 | | RUSS | RUSS | | H02 | C | 430569 |
GENERAL GROWTH | H01 | P | 07/10/1992 | CMB TEETH UPPER LOWER LNDGS | RUSS | RUSS | | H01 | P | 430561 |
GENERAL GROWTH | H02 | C | 01/14/1992 | | RUSS | RUSS | | H02 | C | 430552 |
GENERAL GROWTH | H01 | C | 07/03/1991 | | RUSS | RUSS | | H01 | C | 430545 |
GENERAL GROWTH | H02 | C | 01/29/1991 | | RUSS | RUSS | | H02 | C | 430535 |
GENERAL GROWTH | H01 | C | 07/09/1990 | | RUSS | RUSS | | H01 | C | 430528 |
GENERAL GROWTH | H02 | C | 01/11/1990 | | RUSS | RUSS | | H02 | C | 430520 |
GENERAL GROWTH | H01 | C | 07/10/1989 | | RUSS | RUSS | | H01 | C | 430513 |
GENERAL GROWTH | H02 | C | 01/17/1989 | | RUSS | RUSS | | H02 | C | 430506 |
GENERAL GROWTH | H16 | C | 07/11/1988 | INIT INSP,PERM ISSD | RUSS | RUSS | | H16 | C | 430497 |