CHAPEL HILLS MALL MANAGEMENT OFF. | H07 | C | 03/25/2024 | WITNESSED ESCALATOR SAFETY AND STEP INDEX TESTING WITH ELEVATOR TECHNICIANS -- / NO VISIBLE CODE ISSUES | DUSTINS | DUSTINS | | H07 | C | 8031414 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H05 | C | 07/24/2023 | ESCALATOR DOWN FOR REPAIRS AT TIME OF INSPECTION / ANNUAL WITNESS TESTING TO BE PERFORMED BEFORE ESCALATOR CAN BE RETURNED TO NORMAL SERVICE / RBD NOTE: CREATE H01 WHEN H07 IS PERFORMED | DUSTINS | DUSTINS | | H05 | C | 7805633 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/13/2023 | MONTGOMERY ESCALATOR - UNIT STILL SHUTDOWN PENDING REPAIRS | ROBERTV | ROBERTV | | H02 | C | 7634757 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 12/08/2022 | UNIT STILL SHUTDOWN PENDING REPAIRS - CHECK AT H02 | ROBERTV | ROBERTV | | HE16 | C | 7604593 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/26/2022 | WITNESSED AT H01 - SEE H07 COMMENTS (Receipt #1886320) | ROBERTV | ROBERTV | | H01 | C | 7460754 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H07 | C | 07/26/2022 | WITNESSED ESCALATOR STEP INDEX AND SAFETY TESTING W/ ELEVATOR TECHNICIANS - UPPER AND LOWER DEMARCATION LIGHTS STILL NOT WORKING (2ND NOTICE)......... 30 DAYS TO ADDRESS. COMB PLATES WITH BROKEN TEETH NEED REPLACED....... 30 DAYS TO ADDRESS. STEP TREADWAY FINS ARE NOT MESHING WITH STEP RISERS IN THE INCLINE - THIS NEEDS TO BE DIAGNOSED AND BE PROVIDED WITH A PLAN OF ACTION FOR REPAIR WITHIN 30 DAYS. THE HANDRAIL DRIVE CHAIN WAS ONCE AGAIN ADJUSTED AT TIME OF TESTING TO PASS INSPECTION. DUE TO THE ONGOING ISSUES WITH SLACK AND THE POOR CONDITION OF THE HANDRAIL DRIVE CHAIN, EXAMINATIONS AND/OR ADJUSTMENTS SHALL TAKE PLACE IN INTERVALS NO MORE THAN 6 MONTHS FROM HEREON AND SHALL BE DOCUMENTED IN THE ESCALATOR MAINTENANCE AND REPAIR RECORDS ONSITE. FAILURE TO PROVIDE DOCUMENTATION WILL RESULT IN THE ESCALATOR BEING REMOVED FROM SERVICE. (Updated 10/10/2022 RV - Items have been addressed except step to risers not meshing, escalator to be shut down 12/5/2022) | ROBERTV | ROBERTV | | H07 | C | 7460614 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/21/2022 | MONTGOMERY ESCALATOR W/ ELEV TECH SERVICE - UPPER AND LOWER DEMARCATION LIGHTING NOT WORKING | ROBERTV | ROBERTV | | H02 | C | 7246002 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/26/2021 | MONTGOMERY ESCALATOR - LOWER RIGHT SKIRT TRANSITION PANEL CLEARANCE TO STEP EXCEEDS 3/16". CLEAN UPPER AN LOWER PITS. NEED OIL AND GREASE LOGS ONSITE........... 60 DAYS TO ADDRESS (NOTE: HANDRAIL DRIVE CHAIN HAS BEEN ADJUSTED TO PASS INSPECTION, CHAIN NEEDS MORE ATTENTION THAN ONCE A YEAR. MULTIPLE LOOSE STEP TREADWAYS ALSO HAD TO BE TIGHTENED THROUGHOUT) (MIN BRAKE TORQUE 45 FT/LBS, ACTUAL 50 FT/LBS) (Receipt #1793318) (Repairs have been made RV) | ROBERTV | ROBERTV | | H01 | C | 7049583 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/26/2021 | MONTGOMERY ESCALATOR - MOTOR TO GEARBOX COUPLING NEEDS TO BE REPLACED | ROBERTV | ROBERTV | | H02 | C | 6848472 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/22/2020 | MONTGOMERY ESCALATOR - MOTOR TO GEARBOX COUPLING NEEDS TO BE REPLACED. (Receipt #1698094) | ROBERTV | ROBERTV | | H01 | C | 6646638 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 04/08/2020 | WITNESSED ANNUAL ESCALATOR SAFETY AND STEP INDEX INSPECTION W/ OTIS - MOTOR TO GEARBOX COUPLING NEEDS REPLACED. PITS NEED TO BE CLEANED............(NOTE: BRAKE TORQUE MINIMUM 45 FT/LBS - ACTUAL 55 FT/LBS) | ROBERTV | ROBERTV | | HE16 | C | 6534545 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/13/2020 | MONTGOMERY ESCALATOR - UPPER END HANDRAIL INLET DEVICES MUST BE REPLACED BY NEXT WITNESSED ANNUAL INSPECTION 03/31/2020 | ROBERTV | ROBERTV | | H02 | C | 6450796 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/17/2019 | MONTGOMERY ESCALATOR - UPPER END HANDRAIL INLET DEVICES MUST BE REPLACED BY NEXT ANNUAL 11/2019 (Receipt #1614813 from 07/17/2019) | ROBERTV | ROBERTV | | H01 | C | 6266430 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/31/2019 | MONTGOMERY ESCALATOR - LOWER RIGHT INNER DECK PANEL NEEDS SECURED PROPERLY WITHIN THE NEXT 30 DAYS...... UPPER END HANDRAIL INLET DEVICES NEED TO BE REPLACED WITHIN 90 DAYS
| ROBERTV | ROBERTV | | H02 | C | 6093194 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 11/05/2018 | MONTGOMERY ESCALATOR - WITNESSED ANNUAL STEP INDEX AND SAFETY INSPECTION W/ OTIS. UPPER END HANDRAIL INLETS ARE NOT WORKING PROPERLY AND NEED REPLACED. LOWER COMB PLATES HAVE TEETH BROKEN AND NEED REPLACED. (NOTE: BRAKE TORQUE 47 FT/LBS ------ 45-55 IS REQUIRED) | ROBERTV | ROBERTV | | HE16 | C | 6015980 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/10/2018 | MONTGOMERY ESCALATOR -- HANDRAIL DRIVE CHAIN AND SPROCKET COMPONENTS ARE MAKING SEVERE POPPING NOISE AND CAUSING HANDRAILS TO JERK, ONE CHIPPED STEP NEED TO BE REPLACED, RIGHT HANDRAIL TENSION NEEDS TO BE ADJUSTED, NEED REPAIR/ADJUSTMENTS/CALLBACK LOGS IN ESCALATOR MAINTENANCE CONTROL PROGRAM | ROBERTV | ROBERTV | | H01 | C | 5897524 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/08/2018 | ITEMS AS LISTED ON INSPECTION REPORT DATED 10/2017 AND PRIOR: ------ LOWER LEFT SKIRT BRUSH END CAP NEEDS TO BE INSTALLED, UPPER AND LOWER DEMARCATION LIGHT NOT WORKING, UNKNOWN IF ESCALATOR PIT HAVE BEEN CLEANED | ROBERTV | ROBERTV | | H02 | C | 5731069 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 10/17/2017 | WITNESSED ANNUAL SAFETY INSPECTION AND STEP INDEX TESTING WITH OTIS - LOWER LEFT SKIRT BRUSH END CAP NEEDS TO BE INSTALLED, LOWER DEMARCATION LIGHT NOT WORKING, ESCALATOR PIT NEEDS CLEANED | ROBERTV | ROBERTV | | HE16 | C | 5657870 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/07/2017 | MONTGOMERY W/ OTIS SERVICE -- LOWER LEFT SKIRT BRUSH SECTION AND END CAP MISSING, LOWER LEFT HANDRAIL ENTRY DEVICE MISSING INNER SECTION, BOTH HANDRAILS ARE CRACKING ON TOP SURFACES. NEED ESCALATOR MAINTENANCE CONTROL PROGRAM ONSITE (2ND NOTICE). -- 90 DAYS TO ADDRESS ITEMS TO AVOID SERVICE INTERRUPTION. (Receipt #1437223) | ROBERTV | ROBERTV | | H01 | C | 5556768 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/19/2017 | MONTGOMERY - LOWER DEMARCATION NOT WORKING, NEED ESCALATOR MAINTENANCE CONTROL PROGRAM ONSITE. | ROBERTV | ROBERTV | | H02 | C | 5392536 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 10/28/2016 | PERFORMED ANNUAL STEP INDEX AND SAFETY TESTING W/ OTIS -- LOWER DEMARCATION LIGHTING NOT WORKING, HANDRAIL DRIVE CHAIN NEED MINOR ADJUSTMENT. | ROBERTV | ROBERTV | | HE16 | C | 5330302 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/15/2016 | UNDER REPAIR (Receipt #1341959) | ERIC | ERIC | | H01 | C | 5245679 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/11/2016 | MONTGOMERY W/ OTIS SERVICE. ITEMS HAVE BEEN CORRECTED, STILL NEED SAFETY INSPECTION REPORT FROM 11/2016 (MUST BE RECEIVED BY 2/29/2016), NEED MAINTENANCE CONTROL PROGRAM ONSITE NEXT INSPECTION | ROBERTV | ROBERTV | | H02 | C | 5113198 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 11/23/2015 | ALL ITEMS HAVE BEEN COMPLETED, NEED SAFETY TEST REPORT FROM MECHANIC | ROBERTV | ROBERTV | | HE16 | C | 5085770 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 11/16/2015 | WITNESSED ANNUAL INSPECTION AND TESTING W/ OTIS -- UNIT REMOVED FROM SERVICE BY PPRBD INSPECTOR DUE TO ITEMS LISTED: -- HANDRAIL DRIVE CHAIN IS EXTREMELY LOOSE AND HAS GOUGED THRU THE STEEL STRUCTURAL MEMBER AND 110 VOLT CONDUIT FOR DEMARCATION LIGHTING, ALSO SEVERE GOUGING IS PRESENT ON THE 480 VOLT CONDUIT TO DRIVE MOTOR. REPAIRS AND WELDING ARE REQUIRED BEFORE UNIT CAN BE PUT BACK INTO SERVICE. ADDITIONAL ITEMS LISTED: -- MISSING SECTIONS OF SKIRT BRUSHES AND END CAPS AT LOWER LANDING. SEVERAL STEP TREADWAYS ARE CHIPPED. STILL NEED REPORT AND A STEP INDEXING TEST WILL NEED TO BE PERFORMED IMMEDIATELY AFTER REPAIRS ARE COMPLETED. | ROBERTV | ROBERTV | | HE16 | C | 5079874 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/07/2015 | NEED ANNUAL SAFETY INSPECTION AND INDEX TESTING FOR 2015, PROPERLY SECURE SKIRT BRUSH (Receipt #1272552) | ERIC | ERIC | | H01 | C | 4987372 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 05/11/2015 | INSPECTED ALL STEPS. CLEAN DOWN COMPLETE | ERIC | ERIC | | HE16 | C | 4952473 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/08/2015 | MKE. OTIS SERVICE, DEMARCATION LIGHTS NOT WORKING, NEED CLEAN DOWN AND COMPLETE STEP INSPECTION | ERIC | ERIC | | H02 | C | 4882394 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 12/31/2014 | WITNESSED ANNUAL SAFETY INSPECTION AND INDEX TESTING. DEMARCATION LIGHTS NOT WORKING, NEED CLEAN DOWN AND COMPLETE STEP INSPECTION | ERIC | ERIC | | HE16 | C | 4879226 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/01/2014 | MKE. OTIS SERVICE. VERY JERKY RIDE, NEED ANNUAL SAFETY INSPECTION AND INDEX TESTING FOR 2014 (Receipt #1204919) | ERIC | ERIC | | H01 | C | 4769861 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/16/2014 | MKE. OTIS SERVICE, GAPS IN GLASS PANELS EXCEED CODE SPECS, REPLACE EXCESSIVELY WORN STEP TREADS, NEED ANNUAL SAFETY INSPECTION AND INDEX TESTING FOR 2014 | ERIC | ERIC | | H02 | C | 4673543 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/10/2013 | OUT OF SERVICE FOR REPAIR (Receipt #1141043) | ERIC | ERIC | | H01 | C | 4560622 |
CHAPEL HILLS MALL MANAGEMENT OFF. | HE16 | C | 05/03/2013 | WITNESSED ANNUAL INSPECTION AND INDEX TESTING. NEED HANDRAIL DRIVE CHAIN, STEP CHAIN STRETCHED BEYOND CODE SPECS, NEED STEP SURVEY AT RECHAIN - SEVERAL UNDRILLED "A" CRACKS, DEMARCATION LIGHTS NOT WORKING, NEED CLEAN DOWN AND NEED TO INSTALL DECK BARRICADES IN PROPER LOCATIONS | ERIC | ERIC | | HE16 | C | 4517639 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/22/2013 | MKE. OTIS SERVICE, INSTALL LOWER DECK BARRICADES IN PROPER LOCATIONS, DEMARCATION LIGHTS OUT, NEED ANNUAL WITNESSED INSPECTION AND INDEX TESTING | ERIC | ERIC | | H02 | C | 4458376 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H01 | C | 07/02/2012 | MKE. OTIS SERVICE, NEED LOWER DECK BARRICADES, CHIPPED AND EXCESSIVELY WORN STEP TREADS, DEMARCATION LIGHTS OUT, LOTS OF OIL ON STEPS, HANDRAIL DAMAGED AND MUST BE REPLACED ASAP, NEED INDEX TESTING AND ANNUAL INSPECTION FOR 2012 (Receipt #1056555) | ERIC | ERIC | | H01 | C | 4335326 |
CHAPEL HILLS MALL MANAGEMENT OFF. | H02 | C | 01/09/2012 | MKE. OTIS SERVICE. HANDRAIL NEEDS TO BE REPLACED ASAP, NEED DECK BARRICADES. | ERIC | ERIC | | H02 | C | 4258349 |
COYOTE MANAGEMENT LP | HE16 | C | 08/22/2011 | ANNUAL INSPECTION AND INDEX TESTING COMPLETE | ERIC | ERIC | | HE16 | C | 4196542 |
COYOTE MANAGEMENT LP | H01 | C | 07/13/2011 | MKE. OTIS SERVICE. EXCESSIVELY WORN STEP TREADS, DEMARCATION LIGHTS OUT, NEED LOWER DECK BARRICADES, (Receipt #986134) | ERIC | ERIC | | H01 | C | 4177208 |
GENERAL GROWTH | H02 | C | 01/10/2011 | MKE. NEED ANNUAL INDEX TESTING AND INSPECTION, DEMARCATION LIGHTS OUT | ERIC | ERIC | | H02 | C | 4096705 |
GENERAL GROWTH | H01 | C | 07/16/2010 | NEED ANNUAL INSPECTION AND INDEX TESTING, DEMARCATION LIGHTS OUT (Receipt #920618) | ERIC | ERIC | | H01 | C | 4010845 |
GENERAL GROWTH | H02 | C | 01/07/2010 | MONTGOMERY | ERIC | ERIC | | H02 | C | 3930010 |
GENERAL GROWTH | HE16 | C | 12/15/2009 | WITNESSED INDEX TESTING | ERIC | ERIC | | HE16 | C | 3922964 |
GENERAL GROWTH | H01 | C | 07/15/2009 | MONTGOMERY, NEED ANNUAL PERFORMANCE INDEX TEST (Receipt #867325) | ERIC | ERIC | | H01 | C | 3858771 |
GENERAL GROWTH | HE16 | C | 01/27/2009 | WITNESSED ANNUAL TEAR DOWN AND SAFETY TESTS | ERIC | ERIC | | HE16 | C | 3795415 |
GENERAL GROWTH | H02 | C | 01/27/2009 | MONTGOMERY. MISSING LOWER BARRICADES | ERIC | ERIC | | H02 | C | 3795411 |
GENERAL GROWTH | H01 | C | 07/31/2008 | MONTGOMERY --- DEMARCATION LIGHT OUT AT BOTTOM LANDING (Receipt #819275) | LES | LES | | H01 | C | 3717776 |
GENERAL GROWTH | H02 | C | 01/21/2008 | MONTGOMERY--BOTTOM COMB DAMAGED--HANDRAIL SLIPPING--EXCESSIVE NOISE AT THE TOP | JOHNW | JOHNW | | H02 | C | 433818 |
GENERAL GROWTH | H01 | C | 08/28/2007 | MONTGOMERY--HANDRAIL CRACKED NEEDS REPLACED --EXCESSIVE GAP IN SEVERAL TREADS | JOHNW | JOHNW | | H01 | C | 433810 |
GENERAL GROWTH | H02 | C | 01/31/2007 | MONTGOMERY--MISSING BOTTOM BARRICADES--EXCESSIVE GAP IN SOME OF THE TREADS OF STEPS EXCEED SPECS.--HAND RAIL SLIPPING NEED TO ADJ. INDEX TEST NOT PREFORMED | JOHNW | JOHNW | | H02 | C | 433802 |
GENERAL GROWTH | H01 | C | 07/31/2006 | MONTGOMERY--SOME TREADS ARE WORN THIN -- MISSING LOWER BARICADES | JOHNW | JOHNW | | H01 | C | 433793 |
GENERAL GROWTH | H02 | C | 01/31/2006 | MONTGOMERY--CE46120--HAND RAILS SLIPPING --2 BROKEN TREDS SAME STEP--BOTTOM DEMARCATION LIGHT OUT--SKIRT PANEL STICKING UP ON THE RIGHT SIDE | JOHNW | JOHNW | | H02 | C | 433785 |
GENERAL GROWTH | H01 | C | 07/27/2005 | MONTGOMERY --HANDRAIL SLIPPING | JOHNW | JOHNW | | H01 | C | 433773 |
GENERAL GROWTH | H02 | C | 01/31/2005 | #CE46120 / MONTGOMERY--EMERGENCY STOP ALARM INOP | JOHNW | JOHNW | | H02 | C | 433766 |
GENERAL GROWTH | H01 | C | 07/07/2004 | REPLACE MISSING SCREWS IN SKIRTING | LES | LES | | H01 | C | 433757 |
GENERAL GROWTH | H02 | C | 01/26/2004 | REPAIR SKIRT AT TOP LANDING RIGHT SIDE | LES | LES | | H02 | C | 433751 |
GENERAL GROWTH | H01 | C | 07/16/2003 | REPAIR SKIRTING AT TOP RIGHT LANDING --- 5 BROKEN STEP TREDS --- TOOTH MISSING AT BOTH LANDINGS | LES | LES | | H01 | C | 433743 |
GENERAL GROWTH | H02 | C | 01/23/2003 | TOOTH MISSING AT BOTH LANDINGS --- 4 BROKEN STEP TREDS | LES | LES | | H02 | C | 433736 |
GENERAL GROWTH | H01 | C | 07/19/2002 | TOOTH MISSING AT BOTTOM LANDING | LES | LES | | H01 | C | 433729 |
GENERAL GROWTH | H02 | C | 01/23/2002 | TOOTH MISSING BOTTOM LANDING --- REPLACE ALL MISSING SCREWS IN SKIRTING --- REPAIR DEMARCATION LIGHTS --- CHECK CLEARANCES BETWEEN STEP AND SKIRT | LES | LES | | H02 | C | 433721 |
GENERAL GROWTH | H01 | C | 07/30/2001 | | LES | LES | | H01 | C | 433713 |
GENERAL GROWTH | H02 | R | 01/26/2001 | SHEETMETAL DECHING LOSE | LES | LES | | H02 | R | 433705 |
GENERAL GROWTH | H01 | C | 07/25/2000 | | LES | LES | | H01 | C | 433695 |
GENERAL GROWTH | H02 | C | 01/28/2000 | | TOM | TOM | | H02 | C | 433687 |
GENERAL GROWTH | H01 | C | 07/13/1999 | | RUSS | RUSS | | H01 | C | 433538 |
GENERAL GROWTH | H02 | C | 01/20/1999 | | RUSS | RUSS | | H02 | C | 433530 |
GENERAL GROWTH | H01 | C | 07/23/1998 | | RUSS | RUSS | | H01 | C | 433521 |
GENERAL GROWTH | H02 | C | 01/28/1998 | | RUSS | RUSS | | H02 | C | 433513 |
GENERAL GROWTH | H01 | C | 07/02/1997 | | RUSS | RUSS | | H01 | C | 433679 |
GENERAL GROWTH | H02 | C | 01/11/1997 | | RUSS | RUSS | | H02 | C | 433670 |
GENERAL GROWTH | H01 | P | 07/02/1996 | brkn tooth bottom | RUSS | RUSS | | H01 | P | 433662 |
GENERAL GROWTH | H02 | C | 01/08/1996 | | RUSS | RUSS | | H02 | C | 433655 |
GENERAL GROWTH | H01 | C | 07/20/1995 | | RUSS | RUSS | | H01 | C | 433649 |
GENERAL GROWTH | H02 | C | 01/18/1995 | | RUSS | RUSS | | H02 | C | 433643 |
GENERAL GROWTH | H01 | C | 07/08/1994 | | RUSS | RUSS | | H01 | C | 433638 |
GENERAL GROWTH | H02 | C | 01/24/1994 | | RUSS | RUSS | | H02 | C | 433631 |
GENERAL GROWTH | H01 | C | 07/06/1993 | | RUSS | RUSS | | H01 | C | 433624 |
GENERAL GROWTH | H02 | C | 01/15/1993 | | RUSS | RUSS | | H02 | C | 433615 |
GENERAL GROWTH | H01 | C | 07/10/1992 | | RUSS | RUSS | | H01 | C | 433607 |
GENERAL GROWTH | H02 | C | 01/14/1992 | | RUSS | RUSS | | H02 | C | 433601 |
GENERAL GROWTH | H01 | C | 07/03/1991 | | RUSS | RUSS | | H01 | C | 433593 |
GENERAL GROWTH | H02 | C | 01/30/1991 | | RUSS | RUSS | | H02 | C | 433585 |
GENERAL GROWTH | H01 | C | 07/09/1990 | | RUSS | RUSS | | H01 | C | 433577 |
GENERAL GROWTH | H02 | C | 01/11/1990 | | RUSS | RUSS | | H02 | C | 433570 |
GENERAL GROWTH | H01 | C | 07/10/1989 | | RUSS | RUSS | | H01 | C | 433561 |
GENERAL GROWTH | H02 | C | 02/07/1989 | | RUSS | RUSS | | H02 | C | 433554 |
GENERAL GROWTH | H16 | C | 08/15/1988 | INIT INSP,PERM ISSD | RUSS | RUSS | | H16 | C | 433546 |