TOMA ALLIANCE GROUP LLC | H02 | C | 04/05/2024 | HO2 -- 5 YR 3/22 -- ANNUAL 2/24 -- TKE W/ PEAK SERVICE -- PERFORMED SIX MONTH INSPECTION TO ONLY VERIFY CODE COMPLIANT MCP, LOGS, FIRE FIGHTERS SERVICE OPERATION AND ELEVATOR TWO-WAY COMMUNICATION. / (Receipt #2050293) | BENH | BENH | | H02 | C | 8044070 |
TOMA ALLIANCE GROUP LLC | H01 | C | 10/31/2023 | 5YR -- 3/2022 -- CAT1 -- 2/2023 -- TKE W/ PEAK SERVICE. CAR DOOR RESTRICTOR VANE NEEDS TO BE RELOCATED TO NOT ALLOW CAR DOORS TO OPEN MORE THAN 4 INCHES WHEN CAR IS IN THE RESTRICTION ZONE. NEED TO ADD HOISTWAY FASCIA RESTRICTOR FLAG BETWEEN FLOORS 1 AND 2. TOP OF SHAFT OPEN WIRE DUCT RACEWAY NEEDS THEIR COVERS............... 60 DAYS TO ADDRESS. (Receipt #2003912) corrections made per Russ at Peak 11/2/23 er (Cat1 -- 2/7/2024 RV) | ROBERTV | ROBERTV | | H01 | C | 7905100 |
TOMA ALLIANCE GROUP LLC | H02 | C | 04/26/2023 | HO2 -- ANNUAL 2/23 -- TKE W/ PEAK SERVICE | BENH | BENH | | H02 | C | 7727280 |
TOMA ALLIANCE GROUP LLC | H01 | C | 10/28/2022 | 5YR 03/2022 -- TKE WITH PEAK SERVICE --/ BUILDING TO PROVIDE LOCATION OF GENERATOR TESTING LOGS INSIDE THE MACHINE ROOM --/ NOTE: CONTINUE TO MONITOR SUSPENSION AND GOVERNOR ROPE DIAMETERS (Receipt #1910522) cat 1 2/23 BH | MIKEM | MIKEM | | H01 | C | 7565631 |
TOMA ALLIANCE GROUP LLC | HE16 | C | 06/10/2022 | WITNESSED GENERATOR TESTING WITH GRIFFIS BLESSING AND PEAK ELEVATOR - (GENERATOR TESTING IS OK). FIRE COMMAND CENTER RATH PHONE WILL NOT CONNECT TO CAR. FIRE SERVICE PHASE II SWITCH WORKING INTERMITTENTLY. NEED TO KEEP UP WITH MONTHLY FIRE SERVICE TESTING LOGS, QUARTERLY EMERGENCY PHONE TESTING LOGS, AND ANNUAL GENERATOR TESTING LOGS. LOGS NEED TO BE ACCESSIBLE TO ELEVATOR INSPECTORS (Fire Command Center phone and Phase II key switch have been repaired by Peak, check for logs next inspection RV) | ROBERTV | ROBERTV | | HE16 | C | 7406954 |
TOMA ALLIANCE GROUP LLC | H02 | C | 04/29/2022 | H02 -- ELEVATORS SCHEDULED TO BE REMOVED FROM SERVICE 5/2022 PENDING WITNESS GENERATOR TESTING BEING PERFORMED | ROBERTV | ROBERTV | | H02 | C | 7357996 |
TOMA ALLIANCE GROUP LLC | H06 | C | 03/18/2022 | WITNESSED 5 YEAR TRACTION SAFETY TESTING W/ PEAK ELEVATOR - CAR AND COUNTERWEIGHT BUFFER NEEDS OIL. ELEVATOR GENERATOR TESTING NEEDS TO BE PERFORMED WITH INSPECTOR ONSITE WITHIN 30 DAYS TO PREVENT ELEVATOR FROM BEING REMOVED FROM SERVICE. (NOTE: MONITOR SUSPENSION ROPE DIAMETERS AND WIRE BREAKS) (Receipt #1851754) | ROBERTV | ROBERTV | | H06 | C | 7307688 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/18/2021 | 5YR 02/2017-- ANNUAL 04/2020-- TKE WITH PEAK SERVICE--/ ANNUAL TRACTION CATEGORY 1 SAFETY TEST IS PAST DUE--/ PROVIDE QUARTERLY EMERGENCY PHONE LOGS (note: cat1 completed 12/7/2021 mm) Receipt #1815414) (Receipt #1815414 from 10/18/2021) | MIKEM | MIKEM | | H01 | C | 7144325 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/30/2021 | H02 -- 5 YEAR 2/2017 - ANNUAL 4/2020 -- / SEE PREVIOUS INSPECTION COMMENTS | RANDYB | RANDYB | | H02 | C | 6953261 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/26/2020 | 5YR -- 2/17 -- CAT1 -- 4/20 -- TKE W/ PEAK SERVICE. UNSECURED DOOR ROLLER AT SETSCREW ON "B: FLOOR NEEDS ADDRESSED. PEAK EMERGENCY PHONE OPERATOR COULD NOT IDENTIFY BUILDING LOCATION OR ELEVATOR. NEED QUARTERLY EMERGENCY PHONE TESTING LOG ONSITE. (Receipt #1724418) | ROBERTV | ROBERTV | | H01 | C | 6754021 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/29/2020 | H02 - 5YR -- 2/17 -- CAT1 -- 4/20 -- TKE W/ PEAK SERVICE -- NO ACCESS DUE TO COVID-19 | ROBERTV | ROBERTV | | H02 | C | 6554738 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/21/2019 | 5YR -- 2/17 -- ANNUAL 4/19 -- TKE W/ PEAK SERVICE. ASCENDING CAR OVERSPEED AND UNINTENDED MOTION TESTS NEED PERFORMED NEXT VISIT. TOP FLOOR HOISTWAY ACCESS SWITCH NOT WORKING (Receipt #1638807) | ROBERTV | ROBERTV | | H01 | C | 6374614 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/25/2019 | 5YR -- 2/17 -- ANNUAL 4/19 -- TKE W/ PEAK SERVICE. (ITEMS HAVE BEEN ADDRESSED) | ROBERTV | ROBERTV | | H02 | C | 6177522 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/16/2018 | 5YR -- 2/17 -- ANNUAL 4/18 -- TKE W/ PEAK SERVICE. ASCENDING CAR OVERSPEED AND UNINTENDED MOTION TESTS WERE MARKED "N/A" ON CATEGORY 1 TEST FORMS. THESE TESTS ARE REQUIRED TO BE PERFORMED ANNUALLY PER ASME A17.2 (2.43.2.1(a)(1) AND (b)(1), AND (2.43.2.1(a)(2) AND (b)(2). ALSO, CHECK CAB DOOR RESTRICTOR BAR ENGAGEMENT WITH HOISTWAY FLAGS AND PLATES. CAB DOOR RESTRICTOR BAR MOUNTING AT CAB DOOR IS LOOSE.............90 DAYS TO ADDRESS. (Receipt #1547726) | ROBERTV | ROBERTV | | H01 | C | 5995393 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/06/2018 | 5YR --2--17--DOVER --PEAK SERVICE --ANNUAL TEST EXPIRED | JOHNW | JOHNW | | H02 | C | 5809857 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/18/2017 | 5YR--2--17--DOVER --TKE LOCKBOX NORTH SIDE OF THE BUILDING (Receipt #1460126) | JOHNW | JOHNW | | H01 | C | 5658953 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/03/2017 | H02 -- FINAL INSPECTION COMPLETED 2/2017 | ROBERTV | ROBERTV | | H02 | C | 5462998 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/03/2016 | THIS VISIT SKIPPED -- INSPECTION WILL BE PERFORMED AT MOD FINAL (Receipt #1367574) | ROBERTV | ROBERTV | | H01 | C | 5308452 |
EQUITY GROUP - EXECUTIVE TOWER | H06 | C | 07/29/2016 | WITNESSED AT MODERNIZATION -- SEE INSPECTION NOTES UNDER #J77873 | ROBERTV | ROBERTV | | H06 | C | 5257099 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/11/2016 | STILL UNDERGOING MOD | ROBERTV | ROBERTV | | H02 | C | 5174427 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/26/2015 | 5 YEAR 4/11 TKE AND LOCKBOX. WAIVED REQUIREMENT FOR 5 YEAR TEST UNTIL MODS ARE COMPLETED (Receipt #1295498) | ERIC | ERIC | | H01 | C | 5065640 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/16/2015 | 5 YEAR 4/11 TKE AND LOCKBOX---HO2--MOD SCHEDULED FOR JULY 2015 | ERIC | ERIC | | H02 | C | 4936899 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/21/2014 | 5 YEAR 4/11 TKE AND LOCKBOX. ALARM BELL NOT WORKING (Receipt #1227591) | ERIC | ERIC | | H01 | C | 4839054 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/21/2014 | HO2
| JOHNW | JOHNW | | H02 | C | 4723483 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/16/2013 | 5YR 4-11-DOVER--OPEN ELECTRICAL J-BOX ON CAR TOP (Receipt #1163871) | TOM | TOM | | H01 | C | 4633835 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/18/2013 | 5YR 4-11--DOVER | TOM | TOM | | H02 | C | 4515055 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/18/2012 | 5YR 4-11-DOVER--PHONE IN CAR NOT WORKING (Receipt #1090107) | TOM | TOM | | H01 | C | 4410549 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/16/2012 | 5 YR 4-11--DOVER | TOM | TOM | | H02 | C | 4304128 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/11/2011 | 5 YR 4-11--DOVER--PHONE IN CAR NOT WORKING (Receipt #1009347) | TOM | TOM | | H01 | C | 4229062 |
EQUITY GROUP - EXECUTIVE TOWER | H06 | C | 04/22/2011 | WITNESSED 5 YEAR SAFETY TEST (Receipt #970732) | ERIC | ERIC | | H06 | C | 4139689 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/05/2011 | 5-YR 1-06--DOVER--LIGHT BULB GUARDING IN CAR | TOM | TOM | | H02 | C | 4142476 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/13/2010 | 5 YEAR 1/06 TKE. (Receipt #939018) | ERIC | ERIC | | H01 | C | 4055548 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/08/2010 | 5 YR 1-06--DOVER | TOM | TOM | | H02 | C | 3968373 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/26/2009 | 5 YR 1-06 (Receipt #882550) | TOM | TOM | | H01 | C | 3903092 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/30/2009 | 5 YR 1-06--DOVER | TOM | TOM | | H02 | C | 3829767 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/07/2008 | 5YR 1-06--DOVER (Receipt #833700) | TOM | TOM | | H01 | C | 3764228 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/29/2008 | 5yr--1--06--dover | JOHNW | JOHNW | | H02 | C | 3669515 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/22/2007 | 5 YR 1-06 --- DOVER | LES | LES | | H01 | C | 459910 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/30/2007 | 5 YR 1-06 --- DOVER | LES | LES | | H02 | C | 459901 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/17/2006 | 5 YR 1-06 --- DOVER --- PHONES REPAIRED PER CARL IN MAINTENANCE | LES | LES | | H01 | C | 459893 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/11/2006 | 5 YR 1-06 --- DOVER | LES | LES | | H02 | C | 459887 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/17/2005 | 5 YR TEST DUE --- DOVER --- TOLD CARL IN MAINTENANCE | LES | LES | | H01 | C | 459876 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/04/2005 | 5 YR 1-00 --- DOVER | LES | LES | | H02 | C | 459868 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/20/2004 | 5 YR 1-00 --- DOVER | LES | LES | | H01 | C | 459860 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/09/2004 | 5 YR 1-00 | LES | LES | | H02 | C | 459852 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/06/2003 | 5 YR 1-00 | LES | LES | | H01 | C | 459844 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/04/2003 | 5 YR 1-00 | LES | LES | | H02 | C | 459836 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/30/2002 | 5 YR 1-00 | LES | LES | | H01 | C | 459828 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/15/2002 | 5 YR 1-00 | LES | LES | | H02 | C | 459820 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/17/2001 | 5 YR 1-00 --- DOVER LOCKBOX ON PENTHOUSE DOOR --- 10TH FLOOR REMODEL | LES | LES | | H01 | C | 459812 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/06/2001 | | LES | LES | | H02 | C | 459804 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/12/2000 | | LES | LES | | H01 | C | 459791 |
EQUITY GROUP - EXECUTIVE TOWER | H03 | C | 05/10/2000 | | LES | LES | | H03 | C | 459621 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/14/2000 | 5 YR 1-00--DOVER--LOCKBOX--LIGHT BULB GUARDING IN CAR | TOM | TOM | | H02 | C | 459785 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | R | 10/14/1999 | needs 5yr test | LES | LES | | H01 | R | 459606 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/13/1999 | 5YR DUE THIS YEAR | RUSS | RUSS | | H02 | C | 459600 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/08/1998 | 5yr 4-94 | RUSS | RUSS | | H01 | C | 459590 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/21/1998 | | RUSS | RUSS | | H02 | C | 459581 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/14/1997 | | RUSS | RUSS | | H01 | C | 459778 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/28/1997 | | RUSS | RUSS | | H02 | C | 459769 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/02/1996 | | RUSS | RUSS | | H01 | C | 459760 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/19/1996 | 5yr 5-94 | RUSS | RUSS | | H02 | C | 459751 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/03/1995 | 5yr 5-94 | RUSS | RUSS | | H01 | C | 459743 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/17/1995 | 5yr 5-94 | RUSS | RUSS | | H02 | C | 459736 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/10/1994 | 5YR,5-94 | RUSS | RUSS | | H01 | C | 459728 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | R | 04/25/1994 | 5YR EXPIRED | RUSS | RUSS | | H02 | R | 459721 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/11/1993 | | RUSS | RUSS | | H01 | C | 459715 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/27/1993 | | RUSS | RUSS | | H02 | C | 459708 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/07/1992 | 5YR 11-88 | RUSS | RUSS | | H01 | C | 459700 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/20/1992 | | RUSS | RUSS | | H02 | C | 459693 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/01/1991 | | RUSS | RUSS | | H01 | C | 459684 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/10/1991 | | RUSS | RUSS | | H02 | C | 459675 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/01/1990 | | RUSS | RUSS | | H01 | C | 459667 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/02/1990 | | RUSS | RUSS | | H02 | C | 459659 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/09/1989 | | RUSS | RUSS | | H01 | C | 459651 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 03/07/1989 | | RUSS | RUSS | | H02 | C | 459643 |
EQUITY GROUP - EXECUTIVE TOWER | H16 | C | 12/29/1988 | DEFICIENCIES CORRECTEED | RUSS | RUSS | | H16 | C | 459634 |
EQUITY GROUP - EXECUTIVE TOWER | H16 | C | 10/10/1988 | INIT INSP,PERM ISSD,ORDER:OUTDATED TAGS,5 YR DUE | RUSS | RUSS | | H16 | C | 459628 |