TOMA ALLIANCE GROUP LLC | H02 | C | 04/05/2024 | HO2 -- 5 YR 3/22 -- ANNUAL 2/24 -- TKE W/ PEAK SERVICE -- PERFORMED SIX MONTH INSPECTION TO ONLY VERIFY CODE COMPLIANT MCP, LOGS, FIRE FIGHTERS SERVICE OPERATION AND ELEVATOR TWO-WAY COMMUNICATION. / (Receipt #2050297) | BENH | BENH | | H02 | C | 8044078 |
TOMA ALLIANCE GROUP LLC | H01 | C | 10/31/2023 | 5YR -- 3/2022 -- CAT1 -- 2/2023 -- TKE W/ PEAK SERVICE. CAR DOOR RESTRICTOR VANE NEEDS TO BE RELOCATED TO NOT ALLOW CAR DOORS TO OPEN MORE THAN 4 INCHES WHEN CAR IS IN THE RESTRICTION ZONE. NEED TO ADD HOISTWAY FASCIA RESTRICTOR FLAG BETWEEN FLOORS 1 AND 2. BOTTOM OF COUNTERWEIGHT ROD HARDWARE MISSING COTTER PIN............... 60 DAYS TO ADDRESS. (Receipt #2003940) corrections made per Russ at Peak 11/2/23 er (Cat1 -- 2/7/2024 RV) | ROBERTV | ROBERTV | | H01 | C | 7905142 |
TOMA ALLIANCE GROUP LLC | H02 | C | 04/20/2023 | H02 -- 5YR -- 3/2022 -- CAT1 -- 2/2023 -- TKE W/ PEAK SERVICE. CHECK PREVIOUS LISTED ITEMS AT H01 | ROBERTV | ROBERTV | | H02 | C | 7721892 |
TOMA ALLIANCE GROUP LLC | H01 | C | 10/28/2022 | 5YR 03/2022 -- TKE WITH PEAK SERVICE --/ DOOR OPERATOR MAIN DRIVE BELT IS WORN AND NEEDS TO BE DIAGNOSED --/ COUNTERWEIGHT BOTTOM RODS ARE MISSING THEIR COTTER PINS --/ FIFTH FLOOR HOISTWAY DOORS ARE INTERRUPTING THE S.O.S. WHILE CHECKING DOOR GAPS (Receipt #1910528) cat 1 2/23 BH | MIKEM | MIKEM | | H01 | C | 7565649 |
TOMA ALLIANCE GROUP LLC | HE16 | C | 06/10/2022 | WITNESSED GENERATOR TESTING WITH GRIFFIS BLESSING AND PEAK ELEVATOR - (GENERATOR TESTING IS OK). CAR DOOR CLUTCH IS CLIPPING HOISTWAY DOOR PICKUP ROLLERS ON MULTIPLE FLOORS WHEN RUNNING. FIRE COMMAND CENTER RATH PHONE WILL NOT CONNECT TO CAR. FIRE COMMAND CENTER ELEVATOR PANEL #3 DISPLAY IS NOT WORKING. NEED TO KEEP UP WITH MONTHLY FIRE SERVICE TESTING LOGS, QUARTERLY EMERGENCY PHONE TESTING LOGS, AND ANNUAL GENERATOR TESTING LOGS. LOGS NEED TO BE ACCESSIBLE TO ELEVATOR INSPECTORS (Pickup rollers, phone and lobby panel display have been addressed by Peak, check for logs at next inspection RV) | ROBERTV | ROBERTV | | HE16 | C | 7406966 |
TOMA ALLIANCE GROUP LLC | H02 | C | 04/29/2022 | H02 - ELEVATOR STILL RED TAGGED AND REMOVED FROM SERVICE PENDING WITNESS GENERATOR TESTING | ROBERTV | ROBERTV | | H02 | C | 7357989 |
TOMA ALLIANCE GROUP LLC | H05 | C | 04/18/2022 | FOLLOW-UP TO RED TAGGED ELEVATOR PENDING GENERATOR TESTING:_____ ARRIVED TO FIND ELEVATOR DISCONNECT TURNED BACK ON AND RBD LOCK OUT TAG CUT AND REMOVED. NO PERMISSION WAS GIVEN TO RETURN CAR TO SERVICE. ELEVATOR ONCE AGAIN WAS RED TAGGED AND REMOVED FROM SERVICE WITH LOCK APPLIED TO DISCONNECT PENDING GENERATOR TESTING W/ ELEVATOR COMPANY AND INSPECTOR PRESENT. IF RED TAG IS REMOVED OR ELEVATOR IS TURNED BACK ON, A $1000 FINE PER ELEVATOR / PER DAY WILL BE ENFORCED. | ROBERTV | ROBERTV | | H05 | C | 7342428 |
TOMA ALLIANCE GROUP LLC | H06 | C | 03/18/2022 | WITNESSED 5 YEAR TRACTION SAFETY TESTING W/ PEAK ELEVATOR - CAR BUFFER NEEDS OIL. EMERGENCY LIGHT AND BELL NOT WORKING. EMERGENCY PHONE DOES NOT CONNECT TO MONITORING COMPANY. ELEVATOR GENERATOR TESTING NEEDS TO BE PERFORMED WITH INSPECTOR ONSITE WITHIN. THIS ELEVATOR HAS BEEN REMOVED FROM SERVICE PENDING THESE ITEMS. (NOTE: MONITOR SUSPENSION ROPE DIAMETERS AND WIRE BREAKS) (Receipt #1851755) | ROBERTV | ROBERTV | | H06 | C | 7307690 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/18/2021 | 5YR 02/2017-- ANNUAL 04/2020-- TKE WITH PEAK SERVICE--/ ANNUAL TRACTION CATEGORY 1 SAFETY TEST IS PAST DUE--/ PROVIDE QUARTERLY EMERGENCY PHONE LOGS--/ EMERGENCY LIGHT AND BELL NON FUNCTIONAL WITHOUT 110 CAB CIRCUIT--/ CONTINUE TO MONITOR GOVERNOR ROPE (note: cat1 completed 12/7/2021 mm) (Receipt #1815420) | MIKEM | MIKEM | | H01 | C | 7144341 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/30/2021 | H02 -- 5 YEAR 2/2017 - ANNUAL 4/2020 -- / SEE PREVIOUS INSPECTION COMMENTS | RANDYB | RANDYB | | H02 | C | 6953265 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/26/2020 | 5YR -- 2/17 -- CAT1 -- 4/20 -- TKE W/ PEAK SERVICE. PEAK EMERGENCY PHONE OPERATOR COULD NOT IDENTIFY BUILDING LOCATION OR ELEVATOR. NEED QUARTERLY EMERGENCY PHONE TESTING LOG ONSITE. (Receipt #1724423) | ROBERTV | ROBERTV | | H01 | C | 6754029 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/29/2020 | H02 - 5YR -- 2/17 -- CAT1 -- 4/20 -- TKE W/ PEAK SERVICE -- NO ACCESS DUE TO COVID-19 | ROBERTV | ROBERTV | | H02 | C | 6554740 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/21/2019 | 5YR -- 2/17 -- ANNUAL 4/19 -- TKE W/ PEAK SERVICE. ASCENDING CAR OVERSPEED AND UNINTENDED MOTION TESTS NEED PERFORMED NEXT VISIT. FAR NORTH SUSPENSION ROPE ON COUNTERWEIGHT SIDE IS ALREADY SHOWING UNFAVORABLE WEAR CONDITIONS. MULTIPLE WIRE BREAKS WILL BE MONITORED. (Receipt #1638804) | ROBERTV | ROBERTV | | H01 | C | 6374610 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/25/2019 | 5YR -- 2/17 -- ANNUAL 4/19 -- TKE W/ PEAK SERVICE. (ITEMS HAVE BEEN ADDRESSED) | ROBERTV | ROBERTV | | H02 | C | 6177524 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/16/2018 | 5YR -- 2/17 -- ANNUAL 4/18 -- TKE W/ PEAK SERVICE. ASCENDING CAR OVERSPEED AND UNINTENDED MOTION TESTS WERE MARKED "N/A" ON CATEGORY 1 TEST FORMS. THESE TESTS ARE REQUIRED TO BE PERFORMED ANNUALLY PER ASME A17.2 (2.43.2.1(a)(1) AND (b)(1), AND (2.43.2.1(a)(2) AND (b)(2). ALSO, CHECK CAB DOOR RESTRICTOR BAR ENGAGEMENT WITH HOISTWAY FLAGS AND PLATES. CAB DOOR RESTRICTOR BAR MOUNTING AT CAB DOOR IS LOOSE. MISSING HOISTWAY DOOR GIBB ON 1ST FLOOR...........90 DAYS TO ADDRESS. (Receipt #1547723) | ROBERTV | ROBERTV | | H01 | C | 5995383 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/06/2018 | 5YR--2--17--DOVER -PEAK SERVICE --ANNUAL TEST EXPIRED | JOHNW | JOHNW | | H02 | C | 5809849 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/18/2017 | 5YR--2--17--DOVER --TKE LOCKBOX NORTH SIDE OF THE BUILDING (Receipt #1460127) | JOHNW | JOHNW | | H01 | C | 5658958 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/03/2017 | H02 -- FINAL INSPECTION COMPLETED 2/2017 | ROBERTV | ROBERTV | | H02 | C | 5463000 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/03/2016 | THIS VISIT SKIPPED -- INSPECTION WILL BE PERFORMED AT MOD FINAL (Receipt #1367575) | ROBERTV | ROBERTV | | H01 | C | 5308453 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/11/2016 | WITNESSED AT MODERNIZATION ACCEPTANCE -- SEE PERMIT #J77876 NOTES | ROBERTV | ROBERTV | | H02 | C | 5174417 |
EQUITY GROUP - EXECUTIVE TOWER | H06 | C | 04/11/2016 | WITNESSED AT MODERNIZATION ACCEPTANCE -- SEE PERMIT #J77876 NOTES | ROBERTV | ROBERTV | | H06 | C | 5174416 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/26/2015 | 5 YEAR 4/11 TKE AND LOCKBOX. WAIVED REQUIREMENT FOR 5 YEAR TEST UNTIL MODS ARE COMPLETED (Receipt #1295499) | ERIC | ERIC | | H01 | C | 5065641 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/16/2015 | 5 YEAR 4/11 TKE AND LOCKBOX---HO2--MOD SCHEDULED FOR JULY 2015 | ERIC | ERIC | | H02 | C | 4936900 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/21/2014 | 5 YEAR 4/11 TKE AND LOCKBOX. DAMAGED COUNTERWEIGHT ROLLER (Receipt #1227590) | ERIC | ERIC | | H01 | C | 4839050 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/21/2014 | HO2 | JOHNW | JOHNW | | H02 | C | 4723485 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/16/2013 | 5YR 4-11-DOVER-POSITION INDICATOR LIGHT IN CAR NOT WORKING FOR LANDING "1" (Receipt #1163872) | TOM | TOM | | H01 | C | 4633836 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/18/2013 | 5 YR 4-11--DOVER | TOM | TOM | | H02 | C | 4515053 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/18/2012 | 5YR 4-11--DOVER (Receipt #1090108) | TOM | TOM | | H01 | C | 4410550 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/16/2012 | 5 YR 4-11--DOVER | TOM | TOM | | H02 | C | 4304127 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/11/2011 | 5 YR 4-11--DOVER--PHONE IN CAR NOT WORKING (Receipt #1009346) | TOM | TOM | | H01 | C | 4229061 |
EQUITY GROUP - EXECUTIVE TOWER | H06 | C | 04/25/2011 | WITNESSED 5 YEAR SAFETY TEST (Receipt #970933) | ERIC | ERIC | | H06 | C | 4140172 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/05/2011 | 5YR 1-06--DOVER--PHONE IN CAR NOT WORKING / LEVELING OFF AT LANDING 'LL' | TOM | TOM | | H02 | C | 4142479 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/13/2010 | 5 YEAR 1/06 TKE. CHECK 2 WAY COMMUNICATION ON EMERGENCY PHONE (Receipt #939016) | ERIC | ERIC | | H01 | C | 4055536 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/08/2010 | 5 YR 1-06--DOVER | TOM | TOM | | H02 | C | 3968371 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/26/2009 | 5 YR 1-06 (Receipt #882551) | TOM | TOM | | H01 | C | 3903093 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/30/2009 | 5 YR 1-06--DOVER | TOM | TOM | | H02 | C | 3829768 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/07/2008 | 5YR 1-06--DOVER CHECK PHONE NEXT INSP--RINGS TO STRATMOOR HILLS FIRE DEPT BUT NOT ABLE TO TALK & HEAR CLEARLY (Receipt #833697) | TOM | TOM | | H01 | C | 3764225 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/07/2008 | 5YR 1-06--DOVER CHECK PHONE NEXT INSP--RINGS TO STRATMOOR HILLS FIRE DEPT BUT NOT ABLE TO TALK & HEAR CLEARLY (Receipt #833698) | TOM | TOM | | H01 | C | 3764226 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/29/2008 | 5yr--1--06--dover | JOHNW | JOHNW | | H02 | C | 3669518 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/22/2007 | 5 YR 1-06 --- DOVER | LES | LES | | H01 | C | 460249 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/30/2007 | 5 YR 1-06 --- DOVER | LES | LES | | H02 | C | 460243 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/17/2006 | 5 YR 1-06 --- DOVER | LES | LES | | H01 | C | 460235 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/11/2006 | 5 YR 1-06 --- DOVER | LES | LES | | H02 | C | 460228 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/17/2005 | 5 YR TEST DUE --- DOVER --- TOLD CARL IN MAINTENANCE | LES | LES | | H01 | C | 460220 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/04/2005 | 5 YR 1-00 --- DOVER | LES | LES | | H02 | C | 460214 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/20/2004 | 5 YR 1-00 --- DOVER | LES | LES | | H01 | C | 460205 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/12/2004 | 5 YR 1-00 --- DOVER | LES | LES | | H02 | C | 460193 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/06/2003 | 5 YR 1-00 | LES | LES | | H01 | C | 460185 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/04/2003 | 5 YR 1-00 | LES | LES | | H02 | C | 460177 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/30/2002 | 5 YR 1-00 | LES | LES | | H01 | C | 460171 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/15/2002 | 5 YR 1-00 --- DOVER LOCKBOX OUTSIDE BEHIND TRANSFORMER | LES | LES | | H02 | C | 460165 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/17/2001 | 5 YR 1-00 --- DOVER LOCKBOX ON PENTHOUSE DOOR --- 10TH FLOOR HALL INDICATOR LIGHTS AND SIGNS MISSING DUE TO REMODEL | LES | LES | | H01 | C | 460157 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/06/2001 | | LES | LES | | H02 | C | 460149 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/12/2000 | | LES | LES | | H01 | C | 460141 |
EQUITY GROUP - EXECUTIVE TOWER | H03 | C | 05/10/2000 | | LES | LES | | H03 | C | 459959 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/14/2000 | 5 YR-1-00--DOVER--LOCKBOX @ PENTHOUSE--PHONE INOP--LIGHT BULB GUARDING IN CAR | TOM | TOM | | H02 | C | 460133 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | R | 10/14/1999 | needs 5 yr test | LES | LES | | H01 | R | 459950 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/13/1999 | 5YR DUE THIS YR | RUSS | RUSS | | H02 | C | 459942 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/08/1998 | 5yr 494 | RUSS | RUSS | | H01 | C | 459927 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/21/1998 | | RUSS | RUSS | | H02 | C | 459916 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/14/1997 | | RUSS | RUSS | | H01 | C | 460125 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/28/1997 | | RUSS | RUSS | | H02 | C | 460117 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/02/1996 | | RUSS | RUSS | | H01 | C | 460109 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/19/1996 | 5yr 5-94 | RUSS | RUSS | | H02 | C | 460102 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/03/1995 | 5yr 5-94 | RUSS | RUSS | | H01 | C | 460094 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/17/1995 | 5yr 5-94 | RUSS | RUSS | | H02 | C | 460085 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/10/1994 | 5YR,5-94 | RUSS | RUSS | | H01 | C | 460077 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | R | 04/25/1994 | | RUSS | RUSS | | H02 | R | 460069 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/11/1993 | | RUSS | RUSS | | H01 | C | 460053 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/27/1993 | | RUSS | RUSS | | H02 | C | 460046 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/07/1992 | 5YR11-88,,,,NOT USED? | RUSS | RUSS | | H01 | C | 460037 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/20/1992 | | RUSS | RUSS | | H02 | C | 460029 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/01/1991 | | RUSS | RUSS | | H01 | C | 460021 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/10/1991 | | RUSS | RUSS | | H02 | C | 460016 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/01/1990 | | RUSS | RUSS | | H01 | C | 460007 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 04/02/1990 | | RUSS | RUSS | | H02 | C | 459999 |
EQUITY GROUP - EXECUTIVE TOWER | H01 | C | 10/09/1989 | | RUSS | RUSS | | H01 | C | 459991 |
EQUITY GROUP - EXECUTIVE TOWER | H02 | C | 03/07/1989 | | RUSS | RUSS | | H02 | C | 459984 |
EQUITY GROUP - EXECUTIVE TOWER | H16 | C | 12/29/1988 | DEFICIENCIES CORRECTED | RUSS | RUSS | | H16 | C | 459975 |
EQUITY GROUP - EXECUTIVE TOWER | H16 | C | 10/10/1988 | INIT INSP,PERM ISSD,ORDER:OUTDATED TAGS,5 YR DUE | RUSS | RUSS | | H16 | C | 459967 |